SPECT quantification: a simplified method of attenuation and scatter correction for cardiac imaging.

The quantitative and visual interpretation of SPECT myocardial perfusion images is limited by physical factors such as photon attenuation, Compton scatter, and finite resolution effects. A method of attenuation correction is described for use in nonhomogeneous media and applied to cardiac SPECT imaging. This method, termed multiplicative variable attenuation compensation (MVAC), uses tissue contours determined from segmentation of a transmission scan to assign a priori determined attenuation coefficients to different tissue regions of the transaxial images. An attenuation correction map is then constructed using a technique inspired by Chang's method that includes regionally dependent attenuation within the chest cavity and is applied after reconstruction by filtered backprojection. Scatter correction using the subtraction of a simultaneously acquired scatter window image enables the use of narrow beam attenuation coefficients. Experimental measurements to evaluate these methods were conducted for 201Tl and 99mTc SPECT using a homomorphic cardiac phantom. Finite resolution effects were included in the evaluation of results by computer simulation of the three-dimensional activity distribution. The correction methodology was shown to substantially improve both relative and absolute quantification of uniform and nonuniform regions of activity in the phantom's myocardial wall.

[1]  T F Budinger,et al.  PHYSICAL ATTRIBUTES OF SINGLE‐PHOTON TOMOGRAPHY , 1980, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  C E Floyd,et al.  Nonisotropic attenuation in SPECT: phantom tests of quantitative effects and compensation techniques. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  N. Mullani,et al.  A segmented attenuation correction for PET. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  S. Manglos,et al.  Attenuation maps for SPECT determined using cone beam transmission computed tomography , 1990 .

[5]  M Ljungberg,et al.  Attenuation and scatter correction in SPECT for sources in a nonhomogeneous object: a monte Carlo study. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  Lee-Tzuu Chang,et al.  A Method for Attenuation Correction in Radionuclide Computed Tomography , 1978, IEEE Transactions on Nuclear Science.

[7]  K F Koral,et al.  SPECT dual-energy-window Compton correction: scatter multiplier required for quantification. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  M Ljungberg,et al.  Attenuation correction in SPECT based on transmission studies and Monte Carlo simulations of build-up functions. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  J R Galt,et al.  Effects of myocardial wall thickness on SPECT quantification. , 1990, IEEE transactions on medical imaging.

[10]  D. Bailey,et al.  Improved SPECT using simultaneous emission and transmission tomography. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.