Research on the application of water-loop (tank) heat pump systems in catering buildings

The use of thermal energy in catering buildings is normally mishandled and causes significant waste of thermal energy. To increase the efficient use of energy and decrease the total amount of a catering building’s energy consumption, independent thermal systems should be integrated. If thermal systems are integrated, coupling utilization of thermal energy will be possible, and the primary energy input of a building will be utilized to a greater extent. To implement this concept, a water-loop (tank) heat pump system is necessary and its most important aspect is the design of the thermal storage tank (serving as the water-loop). In this paper, a typical catering building has been selected, and the building’s thermal service systems (processes) are studied in detail. The amount and state of the current thermal energy utilization within each service system is analyzed, and a specific integrated thermal system model is suggested. The research work conducted for this study is based on simulations, such as building thermal load simulations (DesignBuilder software), characteristic simulations of the water-loop heat pump system (TRNSYS software), optimal dimensions and thermal characteristic simulations of the thermal storage tank, etc. The energy consumption characteristic analysis and the technical and economic analysis of the entire building model are discussed, and the optimal scheme for process allocation and optimal operation mode are also presented in this paper. Based on the analytical results (including simulation of building thermal load, simulation of systematic energy consumption, performance analysis of the system, economical analysis, and exergy analysis), the advantages of the system model are demonstrated.

[1]  Li Xinguo,et al.  Thermal performance and energy saving effect of water-loop heat pump systems with geothermal , 1998 .

[2]  Chao Chen,et al.  Underground water-source loop heat-pump air-conditioning system applied in a residential building in Beijing , 2005 .

[3]  Bart Verspagen,et al.  Performance of the Dutch Energy Sector based on energy, exergy and Extended Exergy Accounting. , 2006 .

[4]  Z. Lian,et al.  Conception of combination of gas-engine-driven heat pump and water-loop heat pump system , 2005 .

[5]  Jie Chang,et al.  Synthesis of biodiesel from waste cooking oil using immobilized lipase in fixed bed reactor. , 2009 .

[6]  Wilhelm A. Friess,et al.  Wall insulation measures for residential villas in Dubai: A case study in energy efficiency , 2012 .

[7]  Pradeep K. Sahoo,et al.  Optimization of cooling load for a lecture theatre in a composite climate in India , 2011 .

[8]  Pedro Felizardo,et al.  Production of biodiesel from waste frying oils. , 2006, Waste management.

[9]  Z. Lian,et al.  Analysis on energy consumption of water-loop heat pump system in China , 2005 .

[10]  Mohammad. Rasul,et al.  Energy conservation measures in an institutional building in sub-tropical climate in Australia , 2010 .

[11]  Saeed M. Al-Zahrani,et al.  A TRNSYS Simulation Case Study on Utilization of Heat Pump , 2012 .

[12]  中華人民共和国国家統計局 China statistical yearbook , 1988 .

[13]  Shan K. Wang,et al.  Handbook of Air Conditioning and Refrigeration , 1993 .

[14]  Ravi Prakash,et al.  Life cycle approach in evaluating energy performance of residential buildings in Indian context , 2012 .

[15]  Amip J. Shah,et al.  An Exergy-Based Figure-of-Merit for Electronic Packages , 2006 .

[16]  I. Dincer The role of exergy in energy policy making , 2002 .

[17]  Christopher J. Koroneos,et al.  Exergy analysis of renewable energy sources , 2003 .

[18]  Ali F. Alajmi Energy audit of an educational building in a hot summer climate , 2012 .

[19]  Ibrahim Dincer,et al.  Role of exergy in increasing efficiency and sustainability and reducing environmental impact , 2008 .

[20]  Energy Analysis and Optimization of a Water-Loop Heat Pump System , 2010 .

[21]  Francesco Calise,et al.  Buildings dynamic simulation: Water loop heat pump systems analysis for European climates , 2012 .

[22]  Jacques Miriel,et al.  Modelling and simulation of a heat pump for simultaneous heating and cooling , 2012 .

[23]  C. Bash,et al.  Exergy Analysis of Data Center Thermal Management Systems , 2008 .

[24]  Christopher J. Koroneos,et al.  Energy and exergy utilization assessment of the Greek transport sector , 2008 .