Bioelectric analyses of an osseointegrated intelligent implant design system for amputees.

The projected number of American amputees is expected to rise to 3.6 million by 2050. Many of these individuals depend on artificial limbs to perform routine activities, but prosthetic suspensions using traditional socket technology can prove to be cumbersome and uncomfortable for a person with limb loss. Moreover, for those with high proximal amputations, limited residual limb length may prevent exoprosthesis attachment all together. Osseointegrated implant technology is a novel operative procedure which allows firm skeletal attachment between the host bone and an implant. Preliminary results in European amputees with osseointegrated implants have shown improved clinical outcomes by allowing direct transfer of loads to the bone-implant interface. Despite the apparent advantages of osseointegration over socket technology, the current rehabilitation procedures require long periods of restrictive load bearing prior which may be reduced with expedited skeletal attachment via electrical stimulation. The goal of the osseointegrated intelligent implant design (OIID) system is to make the implant part of an electrical system to accelerate skeletal attachment and help prevent periprosthetic infection. To determine optimal electrode size and placement, we initiated proof of concept with computational modeling of the electric fields and current densities that arise during electrical stimulation of amputee residual limbs. In order to provide insure patient safety, subjects with retrospective computed tomography scans were selected and three dimensional reconstructions were created using customized software programs to ensure anatomical accuracy (Seg3D and SCIRun) in an IRB and HIPAA approved study. These software packages supported the development of patient specific models and allowed for interactive manipulation of electrode position and size. Preliminary results indicate that electric fields and current densities can be generated at the implant interface to achieve the homogenous electric field distributions required to induce osteoblast migration, enhance skeletal fixation and may help prevent periprosthetic infections. Based on the electrode configurations experimented with in the model, an external two band configuration will be advocated in the future.

[1]  R. Misra,et al.  Biomaterials , 2008 .

[2]  D. McCreery,et al.  Neural prostheses : fundamental studies , 1990 .

[3]  H. J. de Jongh,et al.  Prosthetic gait of unilateral transfemoral amputees: a kinematic study. , 1995, Archives of physical medicine and rehabilitation.

[4]  Gerard J. Tortora,et al.  Principles of Human Anatomy , 1977 .

[5]  R. Bulger,et al.  Antimicrobial Agents and Chemotherapy , 1969, Nature.

[6]  M. Kelsey “Annual Review of Microbiology” , 1946, Nature.

[7]  A. J. Clifford,et al.  BIOCHIMICA ET BIOPHYSICA ACTA , 2022 .

[8]  R. DeMatteo American Journal of Surgery , 1916, The Indian Medical Gazette.