A study to compare the reliability of composite finger flexion with goniometry for measurement of range of motion in the hand

Objective: To establish the intra and inter-rater reliability of composite finger flexion (CFF), and to compare this with goniometry. Design: Fifty-one physiotherapists and occupational therapists took part in the study. The hand of a normal subject was splinted in three different positions. Using a goniometer and a ruler alternately, each therapist measured both the proximal interphalangeal joint and CFF of three digits, following a standardized protocol. This process was repeated three times. Setting: Eighteen NHS hospital sites in the UK. Results: The two measurement methods produced different ranges and standard deviations for each digit. The repeatability coef”cient shows that repeated intra-rater goniometric measures fall within 4–5 degrees of each other 95% of the time. Inter-rater goniometric measures fall within 7–9 degrees. Repeated intra-rater CFF measures fall within 5–6 mm of each other, whereas inter-rater fall within 7–9 mm. The in‘uence of occupation, experience in hand therapy, years of practice and routine use were found to have no effect on reliability. Scaling of the two methods of measurement allowed comparison between them to be made. CFF and goniometry are equally reliable when comparing inter-rater reliability, but goniometry displays less variability than composite ”nger ‘exion for intra-rater measurements. Conclusion: In this study involving a subject with normal joints, goniometry is more reliable than CFF when only one measurer is involved. However, CFF may be a useful alternative where multiple joint measures are required, or when goniometry is impracticable.

[1]  Reliability of torque range of motion: a preliminary study. , 1993, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[2]  M. Moore,et al.  The measurement of joint motion; the technic of goniometry. , 1949, The Physical therapy review.

[3]  P. Dijkstra,et al.  Joint mobility measurements: reliability of a standardized method. , 1994, Cranio : the journal of craniomandibular practice.

[4]  J. M. Rothstein Measurement in physical therapy , 1985 .

[5]  J L Low,et al.  The reliability of joint measurement. , 1976, Physiotherapy.

[6]  An Evaluation of Goniometry as an Objective Parameter for Measuring Joint Motion , 1975, Scottish medical journal.

[7]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[8]  Low Jl,et al.  The reliability of joint measurement. , 1976 .

[9]  B Ellis,et al.  Joint angle measurement: a comparative study of the reliability of goniometry and wire tracing for the hand , 1997, Clinical rehabilitation.

[10]  P. LaStayo,et al.  Reliability of passive wrist flexion and extension goniometric measurements: a multicenter study. , 1994, Physical therapy.

[11]  W. B. Conolly,et al.  The Hand: Fundamentals of Therapy , 1988 .

[12]  Richard W. Bohannon,et al.  Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity. , 1987, Physical therapy.

[13]  G F Hamilton,et al.  Reliability of goniometers in assessing finger joint angle. , 1969, Physical therapy.

[14]  D. Joyce White Cynthia C. Norkin,et al.  Measurement of Joint Motion , 1985 .

[15]  M J Healy,et al.  Measuring measuring errors. , 1989, Statistics in medicine.

[16]  R L Lamb,et al.  Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting. , 1991, Physical therapy.

[17]  A. T. Davis,et al.  Hand Injuries: A Therapeutic Approach , 1987 .

[18]  Paul W. Brand,et al.  Clinical mechanics of the hand , 1985 .

[19]  F. A. Hellebrandt,et al.  The Measurement of Joint Motion: Part III—Reliability of Goniometry , 1949 .

[20]  J. J. Gerhardt,et al.  Range-of-motion measurements. , 1995, The Journal of bone and joint surgery. American volume.

[21]  The Measurement of Joint Motion: Part I–Introductory Review of the Literature , 1949 .

[22]  Judith Bell-Krotoski,et al.  Torque range of motion in the hand clinic , 1990 .

[23]  P. Helders,et al.  Goniometry-variability in the clinical practice of a conventional goniometer in healthy subjects , 1994 .

[24]  J. Plewes,et al.  Measurement of joint motion: A guide to goniometry , 1986 .

[25]  Mayerson Nh,et al.  Goniometric measurement reliability in physical medicine. , 1984 .

[26]  Michael J. Callaghan,et al.  Comparison of Visual Estimation and Goniometry in Determination of a Shoulder Joint Angle , 1990 .

[27]  C. Jansen,et al.  Measurement of range of motion of the finger after flexor tendon repair in zone II of the hand. , 1993, The Journal of hand surgery.

[28]  J. Youdas,et al.  Reliability of goniometric measurements and visual estimates of ankle joint active range of motion obtained in a clinical setting. , 1993, Archives of physical medicine and rehabilitation.

[29]  J. M. Hunter,et al.  Rehabilitation of the hand : surgery and therapy , 1995 .

[30]  N. Salter Methods of measurement of muscle and joint function. , 1955, The Journal of bone and joint surgery. British volume.

[31]  Margaret L. Moore The Measurement of Joint Motion: Part II: The Technic of Goniometry , 1949 .

[32]  S. Azen,et al.  Reliability of goniometric measurements. , 1978, Physical therapy.

[33]  J. Ekstrand,et al.  Lower extremity goniometric measurements: a study to determine their reliability. , 1982, Archives of physical medicine and rehabilitation.