Second order multivariate curve resolution applied to the flow injection analysis of mixtures of amino acids

Abstract A flow injection system with diode-array multi-wavelength spectrophotometric detection was used to generate second order data. The system was applied to monitoring the reaction between amino acids (lysine and proline) and l,2-naphthoquinone-4-sulfonate (NQS) to give the corresponding derivatives. The sample injection produced a pH gradient which allowed the discrimination of the time profiles of the different amino acid derivatives. Each amino acid gave a FIA response which was arranged in a data matrix whose chemical rank was higher than one (more than one spectrophotometrically active species was present in the reaction system). The method was applied to the simultaneous determination of Lys and Pro by second order multivariate curve resolution, obtaining a global quantification error of 0.36%. The analysis of one of these amino acids in presence of the other as interference by using a pure standard (without any information about the interference) was also studied. In this case, errors in the quantification were of 2.75 and 3.0% for Lys and Pro, respectively.

[1]  R. Tauler,et al.  Continuous flow titration system for the generation of multivariate spectrophotometric data in the study of acid—base equilibria , 1995 .

[2]  Lars Nørgaard,et al.  RANK ANNIHILATION FACTOR ANALYSIS APPLIED TO FLOW INJECTION ANALYSIS WITH PHOTODIODE-ARRAY DETECTION , 1994 .

[3]  W. Lindberg,et al.  Multicomponent determinations in flow systems by partial least squares modeling , 1988 .

[4]  B. Kowalski,et al.  Selectivity, local rank, three‐way data analysis and ambiguity in multivariate curve resolution , 1995 .

[5]  O. Hernández,et al.  Evaluation of multicomponent flow-injection analysis data by use of a partial least squares calibration method , 1995 .

[6]  B. Kowalski,et al.  Resolution of chemical species in flow injection analysis by using self-modeling curve resolution , 1989 .

[7]  A. Lorber Error propagation and figures of merit for quantification by solving matrix equations , 1986 .

[8]  Jordi Coello,et al.  Multi-component analysis of concentrated solutions by flow-injection analysis with zone sampling and partial least-squares resolution , 1992 .

[9]  J. Saurina,et al.  Simultaneous determination of several amino acids with multivariate calibration methods by using a continuous-flow system , 1995 .

[10]  B. Kowalski,et al.  Theory of analytical chemistry , 1994 .

[11]  R. Tauler Multivariate curve resolution applied to second order data , 1995 .

[12]  Javier Saurina,et al.  Flow-injection spectrophotometric determination of lysine in feed samples , 1993 .

[13]  R. Tauler,et al.  Multivariate curve resolution applied to continuous-flow spectrophotometric titrations. Reaction between amino acids and 1,2-naphthoquinone-4-sulfonic acid , 1995 .

[14]  Gerrit Kateman,et al.  Flow-injection system with photodiode array detection and multivariate data evaluation for quantifying teniposide in blood plasma , 1990 .

[15]  Bruce R. Kowalski,et al.  Tensorial calibration: II. Second‐order calibration , 1988 .

[16]  Gary D. Christian,et al.  Flow chemography — the future of chemical education? , 1990 .

[17]  B. Kowalski,et al.  DOUBLE-INJECTION FLOW INJECTION ANALYSIS USING MULTIVARIATE CALIBRATION FOR MULTICOMPONENT ANALYSIS , 1991 .

[18]  Romà Tauler,et al.  Simultaneous analysis of several spectroscopic titrations with self-modelling curve resolution , 1993 .

[19]  Gary D. Christian,et al.  A simple and robust flow injection analysis method for determination of free acid and metal concentrations in hydrolyzable metal solutions , 1990 .

[20]  B. Kowalski,et al.  Multivariate curve resolution applied to spectral data from multiple runs of an industrial process , 1993 .