Hemodialysis membrane surface chemistry as a barrier to lipopolysaccharide transfer

During hemodialysis bacterial lipopolysaccharide (LPS) in contaminated dialysate solution may translocate across the hollow fiber membrane (HFM) to a patient's blood, resulting in fever and possible systemic shock. This study investigates LPS transfer across, and adsorption within, native and modified Fresenius Optiflux® F200NRe polysulfone (PS)/polyvinyl pyrrolidone (PVP) HFMs. Modifications include varied PVP content, addition of a PS-poly(ethylene glycol) copolymer (PS-PEG), and bleach sterilization. Under clinically relevant flow conditions LPS from >400 EU mL−1 spiked dialysate is not detected (<0.1 EU mL−1) in the lumens of native fibers, but is detected to varying degrees (0.2–15 EU mL−1) in the lumens of the modified fibers. Fluorescently labeled LPS predominantly adsorbs near the lumen of all membranes except the PS-PEG containing membrane, where LPS localizes on the outer wall. Thus, addition of PS-PEG may entrap LPS in the HFM spongy matrix, away from the blood-contacting fiber lumen. © 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2015, 132, 41550.

[1]  G. Schiavano,et al.  Occurrence of fungi in dialysis water and dialysate from eight haemodialysis units in central Italy. , 2014, The Journal of hospital infection.

[2]  M. Mabayoje,et al.  Microbial quality of hemodialysis water, a survey of six centers in Lagos, Nigeria , 2014, Hemodialysis international. International Symposium on Home Hemodialysis.

[3]  M. Arduino,et al.  Hemodialysis and Water Quality , 2013, Seminars in dialysis.

[4]  V. Vicente,et al.  Black Yeasts-Like Fungi Isolated from Dialysis Water in Hemodialysis Units , 2013, Mycopathologia.

[5]  R. Vanholder,et al.  Dialysis water and fluid purity: more than endotoxin. , 2012, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[6]  Zhihong Liu,et al.  Endotoxemia after high cutoff hemodialysis for treatment of patient with multiple myeloma can be prevented by using ultrapure dialysate: A case report , 2012, Hemodialysis international. International Symposium on Home Hemodialysis.

[7]  B. Canaud,et al.  Ultrapure Dialysis Fluid: A New Standard for Contemporary Hemodialysis , 2012, Nephro-urology monthly.

[8]  D. Britt,et al.  Effect of sterilization techniques on the physicochemical properties of polysulfone hollow fibers , 2011 .

[9]  S. McAllister,et al.  Bacteria and endotoxin removal from bicarbonate dialysis fluids for use in conventional, high-efficiency, and high-flux hemodialysis. , 2008, Artificial organs.

[10]  D. Britt,et al.  In vitro assessment of dialysis membrane as an endotoxin transfer barrier: geometry, morphology, and permeability. , 2008, Artificial organs.

[11]  A. Zydney,et al.  In vitro comparison of peracetic acid and bleach cleaning of polysulfone hemodialysis membranes. , 2007, Artificial organs.

[12]  M. Nydén,et al.  Aggregation behavior and size of lipopolysaccharide from Escherichia coli O55:B5. , 2006, Colloids and surfaces. B, Biointerfaces.

[13]  Pierre Aimar,et al.  Experimental study of the effects of hypochlorite on polysulfone membrane properties , 2006 .

[14]  K. Sakai,et al.  Evaluation of the activity of endotoxin trapped by a hollow-fiber dialysis membrane , 2006 .

[15]  A. Mayes,et al.  Polysulfone-graft-poly(ethylene glycol) graft copolymers for surface modification of polysulfone membranes. , 2006, Biomaterials.

[16]  Michael V Sefton,et al.  Endotoxin: the uninvited guest. , 2005, Biomaterials.

[17]  P. Czermak,et al.  New Generation Ceramic Membranes have the Potential of Removing Endotoxins from Dialysis Water and Dialysate , 2005, The International journal of artificial organs.

[18]  R. Vilaginés,et al.  Endotoxin level measurement in hemodialysis biofilm using "the whole blood assay". , 2005, Artificial organs.

[19]  J. Lalucat,et al.  Identification of culturable bacteria present in haemodialysis water and fluid. , 2005, FEMS microbiology ecology.

[20]  A. Zydney,et al.  Effect of bleach on the transport characteristics of polysulfone hemodialyzers , 2004 .

[21]  B. Jaber,et al.  Reprocessed (High-Flux) Polyflux® Dialyzers Resist Trans-Membrane Endotoxin Passage and Attenuate Inflammatory Markers , 2004, Blood Purification.

[22]  K. Sakai,et al.  How polysulfone dialysis membranes containing polyvinylpyrrolidone achieve excellent biocompatibility , 2004 .

[23]  D. Falkenhagen,et al.  Pyrogen transfer across high- and low-flux hemodialysis membranes. , 2004, Artificial organs.

[24]  K. Sugimura,et al.  Biological reactions resulting from endotoxin adsorbed on dialysis membrane: an in vitro study. , 2004, Artificial organs.

[25]  K. Sugimura,et al.  Endotoxin adsorption of various dialysis membranes: in vitro study. , 2003, Artificial organs.

[26]  Robert Levin,et al.  RENAL RESEARCH INSTITUTE SYMPOSIUM: The Implications of Water Quality in Hemodialysis , 2003, Seminars in dialysis.

[27]  Kiyotaka Sakai,et al.  Optimum dialysis membrane for endotoxin blocking , 2003 .

[28]  K. Sugimura,et al.  Investigation of endotoxin adsorption with polyether polymer alloy dialysis membranes. , 2003, International journal of molecular medicine.

[29]  S. Mochizuki,et al.  Visualization of distribution of endotoxin trapped in an endotoxin-blocking filtration membrane , 2002 .

[30]  M. Vervloet,et al.  Lipopolysaccharide Concentrations During Superflux Dialysis Using Unfiltered Bicarbonate Dialysate , 2002, ASAIO journal.

[31]  R. Bellomo,et al.  Endotoxin and cytokine removal in sepsis. , 2002, Therapeutic apheresis : official journal of the International Society for Apheresis and the Japanese Society for Apheresis.

[32]  C. Tetta,et al.  Pyrogen retention by highly permeable synthetic membranes during in vitro dialysis. , 2001, Artificial organs.

[33]  Deventer,et al.  Distribution and Kinetics of Lipoprotein-Bound Endotoxin , 2001, Infection and Immunity.

[34]  G Catapano,et al.  Membranes for endotoxin removal from dialysate: considerations on feasibility of commercial ceramic membranes. , 2000, Artificial organs.

[35]  G. Lonnemann,et al.  Pyrogen Retention by the Asahi APS-650 Polysulfone Dialyzer during In Vitro Dialysis with Whole Human Donor Blood , 2000, ASAIO journal.

[36]  S. Schlotter,et al.  Novel online infusate-assisted dialysis system performs microbiologically safely. , 2000, Artificial organs.

[37]  L. F. Hancock,et al.  Hydrophilic, semipermeable membranes fabricated with poly(ethylene oxide)-polysulfone block copolymer. , 2000, Biomaterials.

[38]  W. Jarvis,et al.  Outbreaks of Infection and/or Pyrogenic Reactions in Dialysis Patients , 2000, Seminars in dialysis.

[39]  T. Groth,et al.  Functionalized nanoparticles for endotoxin binding in aqueous solutions. , 1999, Biomaterials.

[40]  C A Aurell,et al.  Critical aggregation concentrations of gram-negative bacterial lipopolysaccharides (LPS). , 1998, Biochemical and biophysical research communications.

[41]  B. Jaber,et al.  New Polyether Sulfone Dialyzers Attenuate Passage of Cytokine- Inducing Substances from Pseudomonas aeruginosa Contaminated Dialysate , 1998, Blood Purification.

[42]  P. Vaillant,et al.  Evidence of bacterial biofilm in tubing from hydraulic pathway of hemodialysis system. , 1998, Artificial organs.

[43]  C Yamamoto,et al.  Endotoxin rejection by ultrafiltration through high-flux, hollow fiber filters. , 1996, Journal of biomedical materials research.

[44]  F. B. Anspach,et al.  Removal of endotoxins by affinity sorbents. , 1995, Journal of chromatography. A.

[45]  C. A. Smolders,et al.  Chemical treatment of membranes of a polymer blend: Mechanism of the reaction of hypochlorite with poly(vinyl pyrrolidone) , 1995 .

[46]  S. McAllister,et al.  Pyrogenic reactions in patients receiving conventional, high-efficiency, or high-flux hemodialysis treatments with bicarbonate dialysate containing high concentrations of bacteria and endotoxin. , 1992, Journal of the American Society of Nephrology : JASN.

[47]  H. Schiffl High‐Flux Dialyzers, Backfiltration, and Dialysis Fluid Quality , 2011, Seminars in dialysis.

[48]  Y. Iino,et al.  The performance evaluation of endotoxin retentive filters in haemodialysis. , 2011, Journal of Nippon Medical School = Nippon Ika Daigaku zasshi.

[49]  D. Leckband,et al.  Grafted poly(ethylene oxide) brushes as nonfouling surface coatings. , 1999, Journal of biomaterials science. Polymer edition.

[50]  R. Bambauer,et al.  Ultrafiltration of dialysis fluid to obtain a sterile solution during hemodialysis. , 1990, Blood purification.