CFD-modelling of natural convection in a groundwater-filled borehole heat exchanger

In design of ground-source energy systems the thermal performance of the borehole heat exchangers is important. In Scandinavia, boreholes are usually not grouted but left with groundwater to fill the space between heat exchanger pipes and borehole wall. The common U-pipe arrangement in a groundwater-filled BHE has been studied by a three-dimensional, steady-state CFD model. The model consists of a 3 m long borehole containing a single U-pipe with surrounding bedrock. A constant temperature is imposed on the U-pipe wall and the outer bedrock wall is held at a lower constant temperature. The occurring temperature gradient induces a velocity flow in the groundwater-filled borehole due to density differences. This increases the heat transfer compared to stagnant water. The numerical model agrees well with theoretical studies and laboratory experiments. The result shows that the induced natural convective heat flow significantly decreases the thermal resistance in the borehole. The density gradient in the borehole is a result of the heat transfer rate and the mean temperature level in the borehole water. Therefore in calculations of the thermal resistance in groundwater-filled boreholes convective heat flow should be included and the actual injection heat transfer rate and mean borehole temperature should be considered.

[1]  Majid Keyhani,et al.  Free Convection in a Vertical Annulus With Constant Heat Flux on the Inner Wall , 1983 .

[2]  Göran Hellström,et al.  The influence of the thermosiphon effect on the thermal response test , 2003 .

[3]  E. Whalley,et al.  Reanalysis of the density of liquid water in the range 0–150 °C and 0–1 kbar , 1975 .

[4]  A. Abdel-azim Fundamentals of Heat and Mass Transfer , 2011 .

[5]  Johan Claesson,et al.  Analytical Studies of the Influence of Regional Groundwater Flow on the Performance of Borehole Heat Exchangers , 2000 .

[6]  S. Rees,et al.  A preliminary assessment of the effects of groundwater flow on closed-loop ground source heat pump systems , 2000 .

[7]  Göran Hellström,et al.  Influence on thermal response test by groundwater flow in vertical fractures in hard rock , 2003 .

[8]  Signhild Gehlin,et al.  Influence of natural convection in water-filled boreholes for GCHP , 2008 .

[9]  Göran Hellström,et al.  Laboratory study of the heat transfer in a water-filled borehole with a single U-pipe , 1997 .

[10]  Peter Lund,et al.  CALORSTOCK '94, 6th International Conference on Thermal Energy Storage, August 22-25, 1994, Espoo, Finland , 1994 .

[11]  Z. Fang,et al.  Heat transfer analysis of boreholes in vertical ground heat exchangers , 2003 .

[12]  G. Hellström Ground heat storage : thermal analyses of duct storage systems , 1991 .

[13]  P. V. Desai,et al.  Buoyant Laminar Convection in a Vertical Cylindrical Annulus , 1986 .

[14]  Groenholland Bv GEOTHERMAL RESPONSE TESTS USING CONTROLLED MULTI-POWER LEVEL HEATING AND COOLING PULSES (MPL-HCP): QUANTIFYING GROUND WATER EFFECTS ON HEAT TRANSPORT AROUND A BOREHOLE HEAT EXCHANGER , 2006 .