Advantages and disadvantages of a fast fMRI sequence in the context of EEG–fMRI investigation of epilepsy patients: A realistic simulation study

EEG-fMRI is an established technique to allow mapping BOLD changes in response to interictal discharges recorded in the EEG of epilepsy patients. Traditional fMRI experiments rely on an echo planar imaging (EPI) sequence with a time resolution given by its time-to-repetition (TR) of ~2 s. Recently, multiple fast fMRI sequences have been developed to get around the limited temporal resolution of the EPI sequence, and achieved a TR in the 100 ms range or lower. One such sequence is called Magnetic Resonance EncephaloGraphy (MREG). Its high temporal resolution should offer increased detection sensitivity and statistical power in the context of epilepsy studies and in fMRI experiments in general. The aim of this work was to investigate the advantages and disadvantages offered by MREG. This was done by superimposing artificial event-related BOLD responses on EPI and MREG background signals, from 5 epileptic patients, that were free of epileptic discharges (spikes) on simultaneously recorded EEG. These functional datasets simulated different spiking rates and hemodynamic response amplitudes, and were analyzed with the commonly used General Linear Model (GLM) with the canonical hemodynamic response function (HRF) as a fixed model of the response. Robustness to violation of the assumptions of the GLM was additionally assessed with similar simulations using variable spike-to-spike response amplitudes and 8 non-canonical HRFs. Consistent with previous work, MREG yields higher maximum statistical t-values than EPI, but our simulations showed these statistics to be inflated, as the false positive rate at a standard threshold was high. At thresholds set to appropriately control specificity, EPI showed better true positive rate and larger cluster size than MREG. However, the lack of an appropriate calibration of the amplitude of the responses across the sequences precludes definitive judgment on their relative sensitivity. In addition, we show that a mismatch between the assumed and actual HRF impairs more MREG detection performance, but that EPI is more affected by non-modeled spike-to-spike variations of response amplitude. Filtering-out physiological noise, which is not aliased at the fast sampling rate of MREG, and the modeling of temporal autocorrelation are advantageous in increasing the detection power of MREG. This simulation study 1) warrants care when interpreting statistical t-values from fast fMRI sequences, 2) proposes thresholds for valid inferences and processing methods for maximal sensitivities, and 3) demonstrates the relative robustness/susceptibility of MREG and EPI to violation of the GLM's assumptions.

[1]  Catie Chang,et al.  Effects of model-based physiological noise correction on default mode network anti-correlations and correlations , 2009, NeuroImage.

[2]  Jean Gotman,et al.  Increased sensitivity of fast BOLD fMRI with a subject-specific hemodynamic response function and application to epilepsy , 2014, NeuroImage.

[3]  Stephen M. Smith,et al.  Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging , 2010, PloS one.

[4]  Jürgen Hennig,et al.  Single shot whole brain imaging using spherical stack of spirals trajectories , 2013, NeuroImage.

[5]  S. Petersen,et al.  Characterizing the Hemodynamic Response: Effects of Presentation Rate, Sampling Procedure, and the Possibility of Ordering Brain Activity Based on Relative Timing , 2000, NeuroImage.

[6]  Christoph M. Michel,et al.  The spatio-temporal mapping of epileptic networks: Combination of EEG–fMRI and EEG source imaging , 2009, NeuroImage.

[7]  J. Gotman,et al.  fMRI Activation in Continuous and Spike‐triggered EEG–fMRI Studies of Epileptic Spikes , 2003, Epilepsia.

[8]  Jean Gotman,et al.  EEG‐fMRI of focal epileptic spikes: Analysis with multiple haemodynamic functions and comparison with gadolinium‐enhanced MR angiograms , 2004, Human brain mapping.

[9]  J. Polimeni,et al.  Physiological noise reduction using volumetric functional magnetic resonance inverse imaging , 2012, Human brain mapping.

[10]  Kawin Setsompop,et al.  Ultra-fast MRI of the human brain with simultaneous multi-slice imaging. , 2013, Journal of magnetic resonance.

[11]  Frédéric Grouiller,et al.  Characterization of the hemodynamic modes associated with interictal epileptic activity using a deformable model‐based analysis of combined EEG and functional MRI recordings , 2010, Human brain mapping.

[12]  M. D’Esposito,et al.  The Variability of Human, BOLD Hemodynamic Responses , 1998, NeuroImage.

[13]  Matti S Hämäläinen,et al.  Dynamic magnetic resonance inverse imaging of human brain function , 2006, Magnetic resonance in medicine.

[14]  J. Gotman,et al.  Combining EEG and fMRI: A multimodal tool for epilepsy research , 2006, Journal of magnetic resonance imaging : JMRI.

[15]  Oliver Speck,et al.  MR-Encephalography: Fast multi-channel monitoring of brain physiology with magnetic resonance , 2007, NeuroImage.

[16]  Robert Turner,et al.  A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI , 2000, NeuroImage.

[17]  L. Lemieux,et al.  With or without spikes: localization of focal epileptic activity by simultaneous electroencephalography and functional magnetic resonance imaging. , 2011, Brain : a journal of neurology.

[18]  R. Turner,et al.  Event-Related fMRI: Characterizing Differential Responses , 1998, NeuroImage.

[19]  J. Hennig,et al.  Three‐dimensional MR‐encephalography: Fast volumetric brain imaging using rosette trajectories , 2011, Magnetic resonance in medicine.

[20]  J. Hennig,et al.  Fast functional brain imaging using constrained reconstruction based on regularization using arbitrary projections , 2009, Magnetic resonance in medicine.

[21]  J. Polimeni,et al.  Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penalty , 2012, Magnetic resonance in medicine.

[22]  J. Gotman,et al.  Quality of EEG in simultaneous EEG-fMRI for epilepsy , 2003, Clinical Neurophysiology.

[23]  G. Glover Deconvolution of Impulse Response in Event-Related BOLD fMRI1 , 1999, NeuroImage.

[24]  G. Srivastava,et al.  ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner , 2005, NeuroImage.

[25]  Maxim Zaitsev,et al.  Enhancement of temporal resolution and BOLD sensitivity in real-time fMRI using multi-slab echo-volumar imaging , 2012, NeuroImage.

[26]  Jean Gotman,et al.  Limits of 2D-TCA in detecting BOLD responses to epileptic activity , 2011, Epilepsy Research.

[27]  Radu Mutihac,et al.  High-Speed Real-Time Resting-State fMRI Using Multi-Slab Echo-Volumar Imaging , 2013, Front. Hum. Neurosci..

[28]  Jonathan R. Polimeni,et al.  Whole-head rapid fMRI acquisition using echo-shifted magnetic resonance inverse imaging , 2013, NeuroImage.

[29]  Maxim Zaitsev,et al.  Single shot concentric shells trajectories for ultra fast fMRI , 2012, Magnetic resonance in medicine.

[30]  Jean Gotman,et al.  Hemodynamic changes preceding the interictal EEG spike in patients with focal epilepsy investigated using simultaneous EEG-fMRI , 2009, NeuroImage.

[31]  Peter A. Bandettini,et al.  The respiration response function: The temporal dynamics of fMRI signal fluctuations related to changes in respiration , 2008, NeuroImage.

[32]  Timothy D. Verstynen,et al.  Using pulse oximetry to account for high and low frequency physiological artifacts in the BOLD signal , 2011, NeuroImage.

[33]  Jürgen Hennig,et al.  Tracking dynamic resting-state networks at higher frequencies using MR-encephalography , 2013, NeuroImage.

[34]  G H Glover,et al.  Image‐based method for retrospective correction of physiological motion effects in fMRI: RETROICOR , 2000, Magnetic resonance in medicine.

[35]  Mark D'Esposito,et al.  Variation of BOLD hemodynamic responses across subjects and brain regions and their effects on statistical analyses , 2004, NeuroImage.

[36]  Andreas Schulze-Bonhage,et al.  Fast fMRI provides high statistical power in the analysis of epileptic networks , 2014, NeuroImage.

[37]  Louis Lemieux,et al.  Comparison of Spike-Triggered Functional MRI BOLD Activation and EEG Dipole Model Localization , 2001, NeuroImage.

[38]  Jean Gotman,et al.  Independent component analysis reveals dynamic ictal BOLD responses in EEG-fMRI data from focal epilepsy patients , 2010, NeuroImage.

[39]  Peter A. Bandettini,et al.  Separating respiratory-variation-related fluctuations from neuronal-activity-related fluctuations in fMRI , 2006, NeuroImage.

[40]  Alan C. Evans,et al.  A general statistical analysis for fMRI data , 2000, NeuroImage.

[41]  Karl J. Friston,et al.  Analysis of fMRI Time-Series Revisited , 1995, NeuroImage.