An intrafascicular electrode for recording of action potentials in peripheral nerves

We are developing a new type of bipolar recording electrode intended for implantation within individual fascicles of mammalian peripheral nerves. In the experiments reported here we used electrodes fabricated from 25 μm diameter Pt wire, 50 μm 90% Pt-10% Ir wire and 7 μm carbon fibers. The electrodes were implanted in the sciatic nerves of rats and in the ulnar nerves of cats. The signal-to-noise ratio of recorded activity induced by nonnoxious mechanical stimulation of the skin and joints was studied as a function of the type of electrode material used, the amount of insulation removed from the recording zone, and the longitudinal separation of the recording zones of bipolar electrode pairs. Both acute and short term (two day) chronic experiments were performed.The results indicate that a bipolar electrode made from Teflon™-insulated, 25 μm diameter, 90% Pt-10% Ir wire, having a 1–2 mm long recording zone, can be used for recording of peripheral nerve activity when implanted with one wire inside the fascicle and the other lead level with the first lead, but outside the fascicle. No insulating cuff needs to be placed around the nerve trunk.

[1]  R. FitzHugh,et al.  Computation of impulse initiation and saltatory conduction in a myelinated nerve fiber. , 1962, Biophysical journal.

[2]  I. Tasaki,et al.  A NEW MEASUREMENT OF ACTION CURRENTS DEVELOPED BY SINGLE NODES OF RANVIER. , 1964, Journal of neurophysiology.

[3]  R. Plonsey,et al.  A mathematical evaluation of the core conductor model. , 1966, Biophysical journal.

[4]  R. Plonsey,et al.  The extracellular potential field of the single active nerve fiber in a volume conductor. , 1968, Biophysical journal.

[5]  G. J. Romanes,et al.  Current Problems of Lower Vertebrate Phylogeny. , 1969 .

[6]  R. E. Pattle,et al.  The external action potential of a nerve or muscle fibre in an extended medium. , 1971, Physics in medicine and biology.

[7]  R. Stein,et al.  Principles Underlying New Methods for Chronic Neural Recording , 1975, Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques.

[8]  W. B. Marks,et al.  Action currents, internodal potentials, and extracellular records of myelinated mammalian nerve fibers derived from node potentials. , 1976, Biophysical journal.

[9]  G. Loeb,et al.  Parylene as a Chronically Stable, Reproducible Microelectrode Insulator , 1977, IEEE Transactions on Biomedical Engineering.

[10]  S. Sunderland Nerves and nerve injuries , 1978 .

[11]  G. Vantrappen,et al.  A new technique for the recording of single unit activity in small peripheral nerves , 1979, Brain Research.

[12]  F T Hambrecht Neural prostheses. , 1979, Annual review of biophysics and bioengineering.

[13]  F T Hambrecht Clinical application of neural prosthetic techniques. , 1982, Applied neurophysiology.

[14]  Hambrecht Ft Clinical application of neural prosthetic techniques. , 1982 .

[15]  L. Lubińska Patterns of Wallerian degeneration of myelinated fibres in short and long peripheral stumps and in isolated segments of rat phrenic nerve. Interpretation of the role of axoplasmic flow of the trophic factor , 1982, Brain Research.

[16]  T. Bajd,et al.  Gait restoration in paraplegic patients: a feasibility demonstration using multichannel surface electrode FES. , 1983, Journal of rehabilitation R&D.

[17]  H Thoma,et al.  Functional electrostimulation of paraplegics: experimental investigations and first clinical experience with an implantable stimulation device. , 1984, Orthopedics.

[18]  A. Oosterom,et al.  Electrical properties of platinum electrodes: Impedance measurements and time-domain analysis , 2006, Medical and Biological Engineering and Computing.

[19]  P. H. Peckham,et al.  Controlled prehension and release in the C5 quadriplegic elicited by functional electrical stimulation of the paralyzed forearm musculature , 2006, Annals of Biomedical Engineering.

[20]  J. Weinman,et al.  An analysis of electrical properties of metal electrodes , 1964, Medical electronics and biological engineering.