Optimization of X-Ray Computerized Tomography for Polymer Materials

Since polymers mainly consist of the light atomic elements, the transmission of polymers against X-rays is usually too high to be visualized in X-ray microscopy, and hence it has been considered that polymers are not suitable for X-ray computerized tomography (XCT). We calculate the X-ray absorption coefficients of various polymers and find reasonably good conditions for the XCT observations of polymers: the use of 15 KeV X-rays on average can resolve the polystyrene (PS) and poly (methymethacrylate) (PMMA) in 3 µm spatial resolutions. According to this calculation, we build an XCT and experimentally confirm the visualization of the phase-separation structures of PS/PMMA blends.

[1]  Liang Xu,et al.  Effect of Mixing Process and Morphologies on the Electrical Conductivity of PA6/EVA/CB Composites , 2011 .

[2]  W. Yunus,et al.  Morphology, Thermal and Mechanical Properties of Biodegradable Poly(butylene succinate)/Poly(butylene adipate-co-terephthalate)/Clay Nanocomposites , 2010 .

[3]  Wenge Zheng,et al.  The Microcellular Foaming of Polycarbonate/Polystyrene Blends , 2010 .

[4]  A. Bishara,et al.  Thermal, Mechanical and Rheological Properties of Polypropylene/Poly(ethylene-co-methyl acrylate) Blends , 2009 .

[5]  C. Macosko,et al.  Characterizing interface shape evolution in immiscible polymer blends via 3D image analysis. , 2009, Langmuir : the ACS journal of surfaces and colloids.

[6]  M. Dias,et al.  Blends of Poly(hydroxybutyrate) and Poly(ethylene succinate) Prepared in the Presence of Samarium , 2008 .

[7]  C. Macosko,et al.  Synchrotron X-ray microtomography for 3D imaging of polymer blends , 2007 .

[8]  Paolo Ermanni,et al.  Micro-computed tomography determination of glass fibre reinforced polymer meso structure , 2006 .

[9]  Keng S. Liang,et al.  Energy-tunable transmission x-ray microscope for differential contrast imaging with near 60 nm resolution tomography , 2006 .

[10]  Atsushi Momose,et al.  Three-dimensional observation of polymer blend by X-ray phase tomography , 2005 .

[11]  A. Tannenbaum,et al.  The 3D structure of real polymer foams. , 2004, Journal of colloid and interface science.

[12]  Françoise Peyrin,et al.  Three-dimensional quantitative analysis of polymer foams from synchrotron radiation x-ray microtomography , 2003 .

[13]  T. Hashimoto,et al.  Geometrical Properties and Interface Dynamics: Time Evolution of Spinodal Interface in a Binary Polymer Mixture at the Critical Composition , 2000 .

[14]  Peter Wells,et al.  A simple transmission X-ray microtomography instrument , 1992 .

[15]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[16]  Gabor T. Herman,et al.  Image Reconstruction From Projections , 1975, Real Time Imaging.

[17]  E J Burge,et al.  X Rays in Atomic and Nuclear Physics , 1974 .

[18]  S. R. Stock,et al.  X-ray microtomography of materials , 1999 .

[19]  J. H. Hubbell,et al.  Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest , 1995 .