An integrated microfluidic analysis microsystems with bacterial capture enrichment and in-situ impedance detection

In this paper, an integrated microfluidic analysis microsystems with bacterial capture enrichment and in-situ impedance detection was purposed based on microfluidic chips dielectrophoresis technique and electrochemical impedance detection principle. The microsystems include microfluidic chip, main control module, and drive and control module, and signal detection and processing modulet and result display unit. The main control module produce the work sequence of impedance detection system parts and achieve data communication functions, the drive and control circuit generate AC signal which amplitude and frequency adjustable, and it was applied on the foodborne pathogens impedance analysis microsystems to realize the capture enrichment and impedance detection. The signal detection and processing circuit translate the current signal into impendence of bacteria, and transfer to computer, the last detection result is displayed on the computer. The experiment sample was prepared by adding Escherichia coli standard sample into chicken sample solution, and the samples were tested on the dielectrophoresis chip capture enrichment and in-situ impedance detection microsystems with micro-array electrode microfluidic chips. The experiments show that the Escherichia coli detection limit of microsystems is 5 × 104 CFU/mL and the detection time is within 6 min in the optimization of voltage detection 10 V and detection frequency 500 KHz operating conditions. The integrated microfluidic analysis microsystems laid the solid foundation for rapid real-time in-situ detection of bacteria.

[1]  Chih-Ching Huang,et al.  Synthesis of fluorescent carbohydrate-protected Au nanodots for detection of Concanavalin A and Escherichia coli. , 2009, Analytical chemistry.

[2]  R. Konrad,et al.  Send Orders of Reprints at Reprints@benthamscience.net Application of Maldi-tof Ms for the Identification of Food Borne Bacteria , 2022 .

[3]  F. L. Singleton,et al.  Survival and viability of nonculturableEscherichia coli andVibrio cholerae in the estuarine and marine environment , 1982, Microbial Ecology.

[4]  P K Surendran,et al.  Evaluation of culture, ELISA and PCR assays for the detection of Salmonella in seafood , 2007, Letters in applied microbiology.

[5]  Junya Suehiro,et al.  Improvement of electric pulse shape for electropermeabilization-assisted dielectrophoretic impedance measurement for high sensitive bacteria detection , 2005 .

[6]  Lukas W. Snyman,et al.  A silicon transconductance light emitting device (TRANSLED) , 2000 .

[7]  Yang Song,et al.  Nicking enzyme-assisted biosensor for Salmonella enteritidis detection based on fluorescence resonance energy transfer. , 2014, Biosensors & bioelectronics.

[8]  G. Gauglitz,et al.  Microarrays of silicon-based light emitters for novel biosensor and lab-on-a-chip applications , 2005 .

[9]  Florence Postollec,et al.  Recent advances in quantitative PCR (qPCR) applications in food microbiology. , 2011, Food microbiology.

[10]  Junya Suehiro,et al.  Selective detection of bacteria by a dielectrophoretic impedance measurement method using an antibody-immobilized electrode chip , 2006 .

[11]  P Atanasov,et al.  Flow-through immunofiltration assay system for rapid detection of E. coli O157:H7. , 1999, Biosensors & bioelectronics.

[12]  Olivier Lazcka,et al.  Pathogen detection: a perspective of traditional methods and biosensors. , 2007, Biosensors & bioelectronics.