Ring-Shaped Pulse Oximeter and Its Application: Measurement of SpO2 and Blood Pressure During Sleep and During Flight

Respiratory and cardiovascular functions show circadian and day-to-day changes. We have developed a wireless ring-shaped pulse oximeter in collaboration with MC Medical Inc. and Advanced Medical Inc. We investigated the accuracy of this pulse oximeter and its application in daily life. Percutaneous arterial oxygen saturation (SpO2) of 47 volunteers was measured simultaneously with the ring-shaped pulse oximeter and a standard pulse oximeter. A total of 103 volunteers underwent measurement of SpO2 for 24 hr, and 11 healthy volunteers underwent measurement of SpO2 and blood pressure (BP) during flight. SpO2 and heart rate (HR) were measured and recorded every 20 sec, cabin barometric pressure and cabin oxygen concentration equivalent to sea level were measured minute-to-minute, and BP was measured every 3 min with a portable BP recorder during each flight. The SpO2 values measured with the ring-shaped pulse oximeter were similar to those measured with the standard method. The mean SpO2 during sleep was significantly lower in the group with high-normal BP or mild hypertension than in the group with normal BP. During flight, the mean change in SpO2 was − 2.4 ± 1.7% during nose-up flight, and 2.1 ± 2.6% during nose-down flight. There was a significant correlation between change in SpO2 and change in systolic BP during nose-up flight. The wireless ring-shaped pulse oximeter was useful for investigating changes in SpO2 and its effect on BP in daily life during sleep and during air travel.

[1]  F. García-Río,et al.  Sleep apnea and hypertension. , 2000, Chest.

[2]  G. Brundrett,et al.  Comfort and health in commercial aircraft: a literature review , 2001, The journal of the Royal Society for the Promotion of Health.

[3]  W. Nachbauer,et al.  Effects of Aspirin During Exercise on the Incidence of High‐Altitude Headache: A Randomized, Double‐Blind, Placebo‐Controlled Trial , 2001, Headache.

[4]  T. Hayakawa,et al.  Changes in cerebral oxygenation and hemodynamics during obstructive sleep apneas. , 1996, Chest.

[5]  P. Lanfranchi,et al.  Obstructive sleep apnea and vascular disease , 2001, Respiratory research.

[6]  M Ishii,et al.  Effects of insufficient sleep on blood pressure monitored by a new multibiomedical recorder. , 1996, Hypertension.

[7]  B. Berg,et al.  Hypoxemia during air travel in patients with chronic obstructive pulmonary disease. , 1989, Annals of internal medicine.

[8]  J. J. Cottrell Altitude exposures during aircraft flight. Flying higher. , 1988, Chest.

[9]  D. de Bruijn,et al.  Air travel and adults with cyanotic congenital heart disease. , 1996, Circulation.

[10]  O. Tochikubo,et al.  Base heart rate during sleep in hypertensive and normotensive subjects , 2001, Journal of hypertension.

[11]  T. Rabben,et al.  Sleep-disordered breathing and myocardial ischemia in patients with coronary artery disease. , 2000, Chest.

[12]  N. Thomson,et al.  Predictors of nocturnal oxygen desaturation in patients with COPD. , 1999, Respiratory medicine.

[13]  A. Thilmann,et al.  [Pulse oximetry screening for sleep-disordered breathing in stroke]. , 2002, Pneumologie.

[14]  T S Eligulashvili,et al.  [Sleep apnea syndrome]. , 1997, Klinicheskaia meditsina.

[15]  Bruce Neal,et al.  1999 World Health Organization-International Society of Hypertension Guidelines for the Management of Hypertension. Guidelines Subcommittee. , 1999, Journal of hypertension.

[16]  D. Hillman,et al.  Association of sleep apnoea with myocardial infarction in men , 1990, The Lancet.

[17]  K. Strohl,et al.  Extended monitoring of oxygen saturation in chronic lung disease. , 1992, Chest.

[18]  K. Tremper,et al.  Pulse oximetry. , 1989, Anesthesiology.

[19]  A. Gandsas,et al.  In-flight continuous vital signs telemetry via the Internet. , 2000, Aviation, space, and environmental medicine.

[20]  O. Ferrer-Roca,et al.  Aviation medicine: challenges for telemedicine , 2002, Journal of telemedicine and telecare.

[21]  A. Miller,et al.  Lung function testing: selection of reference values and interpretative strategies. , 1992, The American review of respiratory disease.

[22]  E. Bennett,et al.  Changes in cardiac output during air ambulance repatriation , 1996, Intensive Care Medicine.

[23]  K. Woo,et al.  Obstructive sleep apnea presenting with nocturnal angina, heart failure, and near-miss sudden death. , 1991, Chest.

[24]  K. Moser,et al.  Air travel hypoxemia with chronic obstructive pulmonary disease. , 1984, Annals of internal medicine.

[25]  M. Hirshkowitz,et al.  Effect of the new Medicare guideline on patient qualification for positive airway pressure therapy. , 2003, Sleep medicine.

[26]  C. Naspitz,et al.  Pulse oximetry in the evaluation of the severity of acute asthma and/or wheezing in children. , 1999, The Journal of asthma : official journal of the Association for the Care of Asthma.

[27]  F. Yasuma,et al.  Twenty‐four‐hour ambulatory oxygen desaturation and electrocardiographic recording in obstructive sleep apnea syndrome , 1998, Clinical cardiology.