Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings.

STATEMENT OF PROBLEM Marginal fit is an important factor for the long-term success of ceramic restorations; however, it is difficult to compare results from studies on marginal accuracy of zirconium oxide-based restorations that used various computer-assisted systems, because different methods were used to obtain the data. PURPOSE The purpose of this study was to analyze the effect of different manufacturing techniques on the marginal adaptation of zirconia ceramic copings. MATERIAL AND METHODS An extracted mandibular first premolar was prepared for a complete coverage restoration and subsequently duplicated 40 times in a liquid crystal polymer (LCP). Ceramic copings (n=10) were fabricated on the LCP models using the following systems: glass-infiltrated zirconia-toughened alumina (In-Ceram Zirconia) and yttrium cation-doped tetragonal zirconia polycrystals (In-Ceram YZ, Cercon, and Procera Zirconia). The absolute marginal discrepancy of the cores was assessed by using an image analysis system. The data were analyzed using 1-way ANOVA and Scheffé's test (α=.05). RESULTS The mean marginal openings were 29.98 ± 3.97 μm for the In-Ceram Zirconia group, 12.24 ± 3.08 μm for the In-Ceram YZ group, 13.15 ± 3.01 μm for the Cercon group, and 8.67 ± 3.96 μm for the Procera group. Significant differences were found among the 4 systems (P<.05). CONCLUSIONS The marginal accuracy achieved for the 4 zirconia-based ceramic crown systems analyzed was within the range of clinical acceptance (120 μm).

[1]  Kyu-Bok Lee,et al.  Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems. , 2008, Dental materials journal.

[2]  Daniel Edelhoff,et al.  Marginal and internal fits of fixed dental prostheses zirconia retainers. , 2009, Dental materials : official publication of the Academy of Dental Materials.

[3]  H Spiekermann,et al.  Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system. , 2001, Operative dentistry.

[4]  Florian Beuer,et al.  Precision of fit: zirconia three-unit fixed dental prostheses , 2009, Clinical Oral Investigations.

[5]  M. S. Jacobs,et al.  An investigation of dental luting cement solubility as a function of the marginal gap. , 1991, The Journal of prosthetic dentistry.

[6]  M. Andersson,et al.  Accuracy of machine milling and spark erosion with a CAD/CAM system. , 1996, The Journal of prosthetic dentistry.

[7]  P Pera,et al.  In vitro marginal adaptation of alumina porcelain ceramic crowns. , 1994, The Journal of prosthetic dentistry.

[8]  Stig Karlsson,et al.  Precision of a CAD/CAM technique for the production of zirconium dioxide copings. , 2004, The International journal of prosthodontics.

[9]  J. Geis-Gerstorfer,et al.  In vitro evaluation of a glass-ceramic restorative material. , 1997, Journal of oral rehabilitation.

[10]  Kazumichi Wakabayashi,et al.  Marginal and internal fit of Cerec 3 CAD/CAM all-ceramic crowns. , 2003, The International journal of prosthodontics.

[11]  L Pröbster,et al.  Determination of the minimum number of marginal gap measurements required for practical in-vitro testing. , 2000, The Journal of prosthetic dentistry.

[12]  T Sato,et al.  A comparison of the marginal fit of three cast ceramic crown systems. , 1988, The Journal of prosthetic dentistry.

[13]  B Bergman,et al.  The accuracy of a high-precision digitizer for CAD/CAM of crowns. , 1995, The Journal of prosthetic dentistry.

[14]  H. Björn,et al.  Marginal fit of restorations and its relation to periodontal bone level. II. Crowns. , 1970, Odontologisk revy.

[15]  Kazumichi Wakabayashi,et al.  In vitro study on marginal and internal fit of CAD/CAM all-ceramic crowns. , 2005, Dental materials journal.

[16]  I. Denry,et al.  State of the art of zirconia for dental applications. , 2008, Dental materials : official publication of the Academy of Dental Materials.

[17]  K. Knoernschild,et al.  Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures. , 2000, The Journal of prosthetic dentistry.

[18]  Emeka Nkenke,et al.  Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. , 2005, European journal of oral sciences.

[19]  B. Reitz,et al.  Zirconia-TZP and alumina--advanced technologies for the manufacturing of single crowns. , 1999, The European journal of prosthodontics and restorative dentistry.

[20]  D J Setchell,et al.  Influence of marginal configuration and porcelain addition on the fit of In-Ceram crowns. , 1996, Biomaterials.

[21]  M I MacEntee,et al.  Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study. , 1985, The Journal of prosthetic dentistry.

[22]  Wael Att,et al.  Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses. , 2009, The Journal of prosthetic dentistry.

[23]  J. Strub,et al.  Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth. , 1999, Journal of oral rehabilitation.

[24]  S. Bayne,et al.  Considerations in measurement of marginal fit. , 1989, The Journal of prosthetic dentistry.

[25]  Van P Thompson,et al.  Marginal fit of leucite-glass pressable ceramic restorations and ceramic-pressed-to-metal restorations. , 2005, The Journal of prosthetic dentistry.

[26]  G. Christensen Marginal fit of gold inlay castings. , 1966, The Journal of prosthetic dentistry.

[27]  Ariel J Raigrodski,et al.  Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature. , 2004, The Journal of prosthetic dentistry.

[28]  In-Sung Yeo,et al.  In vitro marginal fit of three all-ceramic crown systems. , 2003, The Journal of prosthetic dentistry.

[29]  B. Lang,et al.  Precision of fit: the Procera AllCeram crown. , 1998, The Journal of prosthetic dentistry.

[30]  P. Nicholson,et al.  Phase Analysis in Zirconia Systems , 1972 .

[31]  K. Boening,et al.  Clinical fit of Procera AllCeram crowns. , 2000, The Journal of prosthetic dentistry.

[32]  M. Bottino,et al.  Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents: an in vitro evaluation. , 2004, The Journal of prosthetic dentistry.

[33]  W H Douglas,et al.  Nondestructive, in vitro quantification of crown margins. , 2001, The Journal of prosthetic dentistry.

[34]  José F L Lozano,et al.  Comparative analysis of two measurement methods for marginal fit in metal-ceramic and zirconia posterior FPDs. , 2009, The International journal of prosthodontics.

[35]  J Chai,et al.  A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns. , 1997, The International journal of prosthodontics.

[36]  Patrick M. Kelly,et al.  Transformation Toughening in Zirconia‐Containing Ceramics , 2004 .

[37]  Agneta Oden,et al.  A three-dimensional evaluation of a laser scanner and a touch-probe scanner. , 2006, The Journal of prosthetic dentistry.

[38]  R G Luthardt,et al.  Accuracy of mechanical digitizing with a CAD/CAM system for fixed restorations. , 2001, The International journal of prosthodontics.

[39]  Lothar Borchers,et al.  Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems. , 2009, European journal of oral sciences.

[40]  Gianfranco Gassino,et al.  Marginal adaptation of fixed prosthodontics: a new in vitro 360-degree external examination procedure. , 2004, The International journal of prosthodontics.

[41]  Mehmet Cudi Balkaya,et al.  Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems. , 2005, The Journal of prosthetic dentistry.

[42]  Pablo González de Villaumbrosia,et al.  Comparison of the marginal fit of Procera AllCeram crowns with two finish lines. , 2003, The International journal of prosthodontics.

[43]  Igor J Pesun,et al.  Current ceramic materials and systems with clinical recommendations: a systematic review. , 2007, The Journal of prosthetic dentistry.

[44]  W. Mörmann,et al.  Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations. , 2005, Journal of oral rehabilitation.

[45]  José F L Lozano,et al.  A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation. , 2009, The Journal of prosthetic dentistry.

[46]  Irena Sailer,et al.  Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. , 2007, The International journal of prosthodontics.

[47]  L Pröbster,et al.  Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light and scanning electron microscopic analysis in vitro. , 1997, Journal of oral rehabilitation.

[48]  J. Mclean,et al.  The estimation of cement film thickness by an in vivo technique , 1971, British Dental Journal.

[49]  Francesca Monticelli,et al.  Influence of CAM vs. CAD/CAM scanning methods and finish line of tooth preparation in the vertical misfit of zirconia bridge structures. , 2009, American journal of dentistry.

[50]  José F L Lozano,et al.  Marginal fit of Zirconia posterior fixed partial dentures. , 2008, The International journal of prosthodontics.