Role of intra-operative contrast-enhanced ultrasound (CEUS) in robotic-assisted nephron-sparing surgery

This review examines studies of intra-operative contrast-enhanced ultrasound (CEUS) and its emerging role and advantages in robotic-assisted nephron-sparing surgery. Contrast-enhanced ultrasound is a technology that combines the use of second-generation contrast agents consisting of microbubbles with existent ultrasound techniques. Until now, this novel technology has aided surgeons with procedures involving the liver. However, with recent advances in the CEUS technique and the introduction of robotics in nephron-sparing surgery, CEUS has proven to be efficacious in answering several clinical questions with respect to the kidneys. In addition, the introduction of the microbubble-based contrast agents has increased the image quality and signal uptake by the ultrasound probe. This has led to better, enhanced scanning of the macro and microvasculature of the kidneys, making CEUS a powerful diagnostic modality. This imaging method is capable of further lowering the learning curve and warm ischemia time (WIT) during robotic-assisted nephron-sparing surgery, with its increased level of capillary perfusion and imaging. CEUS has the potential to increase the sensitivity and specificity of intra-operative images, and can significantly improve the outcome of robotic-assisted nephron-sparing surgery by increasing the precision and diagnostic insight of the surgeon. The purpose of this article is to review the practical and potential uses of CEUS as an intra-operative imaging technique during robotic-assisted nephron-sparing surgery.

[1]  Ingolf Schimke,et al.  Does contrast echocardiography with Optison induce myocardial necrosis in humans? , 2002, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[2]  J. Llull,et al.  Human pharmacokinetics and safety evaluation of SonoVue, a new contrast agent for ultrasound imaging. , 2000, Investigative radiology.

[3]  Inderbir S Gill,et al.  Every minute counts when the renal hilum is clamped during partial nephrectomy. , 2010, European urology.

[4]  A. Shalhav,et al.  Chronic kidney disease before and after partial nephrectomy. , 2011, The Journal of urology.

[5]  Tianfu Wu,et al.  Contrast-enhanced ultrasound with SonoVue could accurately assess the renal microvascular perfusion in diabetic kidney damage. , 2012, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[6]  Christian Greis,et al.  Technology overview: SonoVue (Bracco, Milan). , 2004, European radiology.

[7]  M. Menon,et al.  Robotic ultrasound probe for tumor identification in robotic partial nephrectomy: Initial series and outcomes , 2013, International journal of urology : official journal of the Japanese Urological Association.

[8]  M. Sangalli,et al.  Impact of the learning curve on perioperative outcomes in patients who underwent robotic partial nephrectomy for parenchymal renal tumours. , 2010, European urology.

[9]  L Barozzi,et al.  The EFSUMB Guidelines and Recommendations on the Clinical Practice of Contrast Enhanced Ultrasound (CEUS): Update 2011 on non-hepatic applications , 2011, Ultraschall in der Medizin.

[10]  M. Robbin,et al.  Perflenapent emulsion: a US contrast agent for diagnostic radiology--multicenter, double-blind comparison with a placebo. EchoGen Contrast Ultrasound Study Group. , 1998, Radiology.

[11]  B. Oftedal,et al.  Safety of the transpulmonary ultrasound contrast agent NC100100: a clinical and haemodynamic evaluation in patients with suspected or proved coronary artery disease , 1999, Heart.

[12]  A. Rao,et al.  Occlusion angiography using intraoperative contrast-enhanced ultrasound scan (CEUS): a novel technique demonstrating segmental renal blood supply to assist zero-ischaemia robot-assisted partial nephrectomy. , 2013, European urology.

[13]  G M Baxter,et al.  Current and potential renal applications of contrast-enhanced ultrasound. , 2012, Clinical radiology.

[14]  L. Su,et al.  Intraoperative optical imaging and tissue interrogation during urologic surgery , 2014, Current opinion in urology.

[15]  Guang-Zhong Yang,et al.  Intraoperative ultrasound overlay in robot-assisted partial nephrectomy: first clinical experience. , 2014, European urology.

[16]  Akshay Bhandari,et al.  Maximizing console surgeon independence during robot-assisted renal surgery by using the Fourth Arm and TilePro. , 2009, Journal of endourology.

[17]  A. Nilsson Contrast–enhanced ultrasound of the kidneys , 2004, European radiology.

[18]  Georg Bartsch,et al.  Robotic-assisted laparoscopic partial nephrectomy: technique and initial clinical experience with DaVinci robotic system. , 2004, Urology.

[19]  Edward Messing,et al.  Near infrared fluorescence imaging after intravenous indocyanine green: initial clinical experience with open partial nephrectomy for renal cortical tumors. , 2012, Urology.

[20]  F D Scholle,et al.  Acoustic behaviour of current ultrasound contrast agents. , 2000, Ultrasonics.

[21]  S. Bhayani,et al.  Robotic partial nephrectomy with sliding-clip renorrhaphy: technique and outcomes. , 2009, European urology.

[22]  M. Stifelman,et al.  Robot assisted partial nephrectomy versus laparoscopic partial nephrectomy for renal tumors: a multi-institutional analysis of perioperative outcomes. , 2009, The Journal of urology.

[23]  D. Cosgrove,et al.  Liver tumors: evaluation with contrast-enhanced ultrasound. , 2004, Abdominal imaging.

[24]  L. Bolondi,et al.  The safety of Sonovue in abdominal applications: retrospective analysis of 23188 investigations. , 2006, Ultrasound in medicine & biology.

[25]  Jean-Jacques Patard,et al.  EAU guidelines on renal cell carcinoma: the 2010 update. , 2010, European urology.