Alternative quality control of steel fibre reinforced sprayed concrete (SFRSC)

Abstract Steel fibre reinforced sprayed concrete (SFRSC) is used in applications with high structural capacity requirements. The quality control of SFRSC typically includes the assessment of toughness-related properties and measurement of the fibre content. The toughness may be measured with the beam test to EN 14488-3:2006, whereas the fibre content is generally measured by manual methods, such as collecting and weighing the fibres. Both procedures are time-consuming, difficult to perform and challenging to conduct with specimens extracted from the in-situ structure. These difficulties can therefore limit the frequency of characterization and hence potentially compromise the reliability of the information obtained, thus hindering the capacity of engineers to either detect potential problems or to optimize the material. The objective of this work therefore is to explore a simpler SFRSC quality control system that includes the inductive method for the assessment of fibre content and the Barcelona test for the assessment of toughness. Dry-mix SFRSC with five fibre contents were sprayed and tested with beam, Barcelona and inductive tests. Results confirm the greater sensitivity of the Barcelona test and the advantages of combining it with the inductive method for an enhanced quality control. Furthermore, equations are proposed to predict the beam test results using the Barcelona test results. These equations provide a good fit (R2 = 0.97) regardless of the fibre content in the mix, thus confirming the robustness of the approach both for the classification and for the quality control of SFRSC.

[1]  S. Austin,et al.  Material and fibre losses with fibre reinforced sprayed concrete , 1997 .

[2]  A. Figueiredo,et al.  Influence of the instability of the double punch test on the post-crack response of fiber-reinforced concrete , 2019, Construction and Building Materials.

[3]  Antonio Aguado,et al.  Improved assessment of fibre content and orientation with inductive method in SFRC , 2015 .

[4]  I. Galobardes,et al.  Estimation of the modulus of elasticity for sprayed concrete , 2014 .

[5]  S. Cavalaro,et al.  Correlation between the Barcelona test and the bending test in fibre reinforced concrete , 2017 .

[6]  J. M. Torrents,et al.  Assessment of fibre content and 3D profile in cylindrical SFRC specimens , 2016 .

[7]  Christopher K.Y. Leung,et al.  Properties of wet-mixed fiber reinforced shotcrete and fiber reinforced concrete with similar composition , 2005 .

[8]  Renata Monte,et al.  Avaliação da tenacidade de concretos reforçados com fibras através de ensaios com sistema aberto , 2014 .

[9]  Simon A. Austin,et al.  Flexural strain and crack width measurement of steel-fibre-reinforced concrete by optical grid and electrical gauge methods , 2001 .

[10]  S. W. Dean,et al.  Influence of Test Machine Control Method on Flexural Performance of Fiber Reinforced Concrete Beams , 2009 .

[11]  C. Molins,et al.  Use of BCN test for controlling tension capacity of fiber reinforced shotcrete in mining works , 2019, Construction and Building Materials.

[12]  Jorge J. Moré,et al.  The Levenberg-Marquardt algo-rithm: Implementation and theory , 1977 .

[13]  Alejandro Josa,et al.  Bi-layer diaphragm walls: Experimental and numerical structural analysis , 2013 .

[14]  H. Armelin STEEL FIBRE REINFORCED DRY-MIX SHOTCRETE: FIBRE ORIENTATION AND ITS EFFECT ON MECHANICAL PROPERTIES , 1992 .

[15]  Antonio Aguado,et al.  Multidirectional double punch test to assess the post-cracking behaviour and fibre orientation of FRC , 2014 .

[16]  Sprayed Concrete Technology , 2002 .

[17]  Antonio Aguado,et al.  Inductive method for assessing the amount and orientation of steel fibers in concrete , 2012 .

[18]  W. F. Chen,et al.  Double punch test for tensile strength of concrete, Sept. 1969 (70-18) PB224770/AS (NTIS) , 1969 .

[19]  Climent Molins i Borrell,et al.  Control de la tenacidad de los hormigones reforzados con fibras usando el ensayo de doble punzonamiento (ensayo barcelona) , 2009 .

[20]  Chris I. Goodier,et al.  Maturity method to predict the evolution of the properties of sprayed concrete , 2015 .

[21]  S. Cavalaro,et al.  Intrinsic scatter of FRC: an alternative philosophy to estimate characteristic values , 2015 .

[22]  Antonio Aguado,et al.  Constitutive model for fibre reinforced concrete based on the Barcelona test , 2014 .