Detecting subtle plasma membrane perturbation in living cells using second harmonic generation imaging.

The requirement of center asymmetry for the creation of second harmonic generation (SHG) signals makes it an attractive technique for visualizing changes in interfacial layers such as the plasma membrane of biological cells. In this article, we explore the use of lipophilic SHG probes to detect minute perturbations in the plasma membrane. Three candidate probes, Di-4-ANEPPDHQ (Di-4), FM4-64, and all-trans-retinol, were evaluated for SHG effectiveness in Jurkat cells. Di-4 proved superior with both strong SHG signal and limited bleaching artifacts. To test whether rapid changes in membrane symmetry could be detected using SHG, we exposed cells to nanosecond-pulsed electric fields, which are believed to cause formation of nanopores in the plasma membrane. Upon nanosecond-pulsed electric fields exposure, we observed an instantaneous drop of ~50% in SHG signal from the anodic pole of the cell. When compared to the simultaneously acquired fluorescence signals, it appears that the signal change was not due to the probe diffusing out of the membrane or changes in membrane potential or fluidity. We hypothesize that this loss in SHG signal is due to disruption in the interfacial nature of the membrane. The results show that SHG imaging has great potential as a tool for measuring rapid and subtle plasma membrane disturbance in living cells.

[1]  Douglas L. Miller,et al.  Sonoporation: Mechanical DNA Delivery by Ultrasonic Cavitation , 2002, Somatic cell and molecular genetics.

[2]  Laura Marcu,et al.  Calcium bursts induced by nanosecond electric pulses. , 2003, Biochemical and biophysical research communications.

[3]  Leslie M Loew,et al.  Characterization and application of a new optical probe for membrane lipid domains. , 2006, Biophysical journal.

[4]  B. Salzberg,et al.  Novel naphthylstyryl-pyridinium potentiometric dyes offer advantages for neural network analysis , 2004, Journal of Neuroscience Methods.

[5]  Winfried Denk,et al.  Second-harmonic generation imaging of membrane potential with retinal analogues. , 2011, Biophysical journal.

[6]  Enrico Gratton,et al.  Laurdan and Prodan as Polarity-Sensitive Fluorescent Membrane Probes , 1998, Journal of Fluorescence.

[7]  J Mertz,et al.  Coherent scattering in multi-harmonic light microscopy. , 2001, Biophysical journal.

[8]  Dobryna Zalvidea,et al.  Second Harmonic Generation for time-resolved monitoring of membrane pore dynamics subserving electroporation of neurons , 2011, Biomedical optics express.

[9]  E. Neumann,et al.  Gene transfer into mouse lyoma cells by electroporation in high electric fields. , 1982, The EMBO journal.

[10]  Bennett L Ibey,et al.  Lipid nanopores can form a stable, ion channel-like conduction pathway in cell membrane. , 2009, Biochemical and biophysical research communications.

[11]  Dustin G. Mixon,et al.  Plasma membrane permeabilization by trains of ultrashort electric pulses. , 2010, Bioelectrochemistry.

[12]  L M Loew,et al.  High-resolution nonlinear optical imaging of live cells by second harmonic generation. , 1999, Biophysical journal.

[13]  L Sacconi,et al.  Overcoming photodamage in second-harmonic generation microscopy: real-time optical recording of neuronal action potentials. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[14]  Caleb C Roth,et al.  Resolving the spatial kinetics of electric pulse-induced ion release. , 2012, Biochemical and biophysical research communications.