Three-Year Experience Using Near Infrared Spectroscopy Tissue Oximetry Monitoring of Free Tissue Transfers

Early recognition of threatened free-flap failure is paramount to flap salvage. A noninvasive, reproducible, sensitive monitoring tool would be a useful adjunct to clinical examination. The purpose of this study was to examine outcomes using a near-infrared spectroscopy (NIRS) tissue oximeter for postoperative flap monitoring. A total of 128 free flaps were performed in 113 patients over a 3 year period. The patients were divided into 2 cohorts: conventional monitoring (group 1) and conventional monitoring plus NIRS oximetry (group 2). Overall flap survival was 90.6% in group 1 and 98.7% in group 2 (P = 0.05). Overall survival of threatened flaps was 0% (0/5) in the conventional group and 87.5% (6/7) in the oximeter group, P = 0.005. Salvage of operated flaps was significantly improved in group 2: 0% (0/4) in group 1 versus 100% (3/3) in group 2, P = 0.03. The sensitivity, specificity, and predictive values for detecting threatened flap loss were 100%. The NIRS tissue oximeter is a highly reliable, sensitive, and specific, noninvasive method for postoperative free tissue transfer monitoring.

[1]  Haishu Ding,et al.  Evaluation of near infrared spectroscopy in monitoring postoperative regional tissue oxygen saturation for fibular flaps. , 2008, Journal of plastic, reconstructive & aesthetic surgery : JPRAS.

[2]  J C Yuen,et al.  Monitoring Free Flaps Using the Laser Doppler Flowmeter: Five‐Year Experience , 2000, Plastic and reconstructive surgery.

[3]  H G Machens,et al.  Techniques of postoperative blood flow monitoring after free tissue transfer: An overview , 1994, Microsurgery.

[4]  R. J. Fix,et al.  Retrospective Review of the Internal Doppler Probe for Intra- and Postoperative Microvascular Surveillance , 2003, Journal of reconstructive microsurgery.

[5]  D A Hidalgo,et al.  Efficacy of conventional monitoring techniques in free tissue transfer: an 11-year experience in 750 consecutive cases. , 1999, Plastic and reconstructive surgery.

[6]  Alex Keller,et al.  A New Diagnostic Algorithm for Early Prediction of Vascular Compromise in 208 Microsurgical Flaps Using Tissue Oxygen Saturation Measurements , 2009, Annals of plastic surgery.

[7]  Fu-Chan Wei,et al.  Timing of Presentation of the First Signs of Vascular Compromise Dictates the Salvage Outcome of Free Flap Transfers , 2007, Plastic and reconstructive surgery.

[8]  Gregory R. D. Evans,et al.  Timing of Pedicle Thrombosis and Flap Loss after Free‐Tissue Transfer , 1996, Plastic and reconstructive surgery.

[9]  N. Jones,et al.  Intraoperative and postoperative monitoring of microsurgical free tissue transfers. , 1992, Clinics in plastic surgery.

[10]  P. Werker,et al.  Advancements in Free Flap Monitoring in the Last Decade: A Critical Review , 2010, Plastic and reconstructive surgery.

[11]  C. S. Jones,et al.  The role of emergent exploration in free-tissue transfer: a review of 150 consecutive cases. , 1990, Plastic and reconstructive surgery.

[12]  Z. Arnež,et al.  Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy. , 2008, Journal of plastic, reconstructive & aesthetic surgery : JPRAS.

[13]  W. Lineaweaver The implantable Doppler probe. , 1988, Plastic and Reconstructive Surgery.

[14]  P. Butler,et al.  Postoperative monitoring of free flaps in UK plastic surgery units , 2005, Microsurgery.

[15]  S. Mardini,et al.  Flap Monitoring and Patient Management , 2009, Plastic and reconstructive surgery.

[16]  Kan-Zhi Liu,et al.  Assessment of Skin Flaps Using Optically Based Methods for Measuring Blood Flow and Oxygenation , 2005, Plastic and reconstructive surgery.

[17]  C J Green,et al.  Near infra-red spectroscopy: a non-invasive monitor of perfusion and oxygenation within the microcirculation of limbs and flaps. , 1995, British Journal of Plastic Surgery.

[18]  R. Koller,et al.  Continuous Free-Flap Monitoring with Tissue-Oxygen Measurements: Three-Year Experience , 2002, Journal of reconstructive microsurgery.

[19]  Duc T. Bui,et al.  Free Flap Reexploration: Indications, Treatment, and Outcomes in 1193 Free Flaps , 2007, Plastic and reconstructive surgery.

[20]  C J Green,et al.  The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery. , 1998, British journal of plastic surgery.

[21]  Reimer Andresen,et al.  Investigation of TRAM Flap Oxygenation and Perfusion by Near-Infrared Reflection Spectroscopy and Color-Coded Duplex Sonography , 2004, Plastic and reconstructive surgery.

[22]  W. Lineaweaver,et al.  Improved salvage of complicated microvascular transplants monitored with quantitative fluorometry. , 1992, Plastic and reconstructive surgery.

[23]  I. Whitaker,et al.  The efficacy of clinical assessment in the postoperative monitoring of free flaps: a review of 1140 consecutive cases. , 2010, Plastic and reconstructive surgery.

[24]  A. Colwell,et al.  Near-infrared spectroscopy measures tissue oxygenation in free flaps for breast reconstruction. , 2008, Plastic and reconstructive surgery.

[25]  T. Nakatsuka,et al.  Analytic review of 2372 free flap transfers for head and neck reconstruction following cancer resection. , 2003, Journal of reconstructive microsurgery.

[26]  A. Kunselman,et al.  A Prospective Study of Microvascular Free‐Flap Surgery and Outcome , 1998, Plastic and reconstructive surgery.

[27]  Neil F. Jones,et al.  Direct Monitoring of Microvascular Anastomoses with the 20‐MHz Ultrasonic Doppler Probe: An Experimental and Clinical Study , 1988, Plastic and reconstructive surgery.

[28]  Bruno D Fornage,et al.  Monitoring Buried Free Flaps: Limitations of the Implantable Doppler and Use of Color Duplex Sonography as a Confirmatory Test , 2006, Plastic and reconstructive surgery.

[29]  Frank Hölzle,et al.  Free flap monitoring using simultaneous non-invasive laser Doppler flowmetry and tissue spectrophotometry. , 2006, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[30]  Alex Keller,et al.  Noninvasive tissue oximetry for flap monitoring: an initial study. , 2007, Journal of reconstructive microsurgery.

[31]  H J Buncke,et al.  The Effect of an Implantable Doppler Probe on the Salvage of Microvascular Tissue Transplants , 1998, Plastic and reconstructive surgery.

[32]  R. Khouri Avoiding free flap failure. , 1992, Clinics in plastic surgery.

[33]  D. Brooks,et al.  Detection of perfusion disturbances in digit replantation using near-infrared spectroscopy and serial quantitative fluoroscopy. , 2006, The Journal of hand surgery.

[34]  M. Urken,et al.  Continuous Tissue Oxygen Tension Measurement as a Monitor of Free‐Flap Viability , 1997, Plastic and reconstructive surgery.

[35]  L. Levin,et al.  Laser Doppler Flowmeter Monitoring of FreeTissue Transfers: Blood Flow in Normal and Complicated Cases , 2001, Plastic and reconstructive surgery.