IMU Sensor-Based Electronic Goniometric Glove for Clinical Finger Movement Analysis

Arthritis remains a disabling and painful disease, and involvement of finger joints is a major cause of disability and loss of employment. Traditional arthritis measurements require labour intensive examination by clinical staff. These manual measurements are inaccurate and open to observer variation. This paper presents the development and testing of a next generation wireless smart glove to facilitate the accurate measurement of finger movement through the integration of multiple IMU sensors, with bespoke controlling algorithms. Our main objective was to measure finger and thumb joint movement. These dynamic measurements will provide clinicians with a new and accurate way to measure loss of movement in patients with rheumatoid arthritis. Commercially available gaming gloves are not fitted with sufficient sensors for this particular application, and require calibration for each glove wearer. Unlike these state-of-the-art data gloves, the inertial measurement unit glove uses a combination of novel stretchable substrate material and nine degree of freedom inertial sensors in conjunction with complex data analytics to detect joint movement. Our novel iSEG-Glove requires minimal calibration and is therefore particularly suited to the healthcare environment. Inaccuracies may arise for wearers who have varying degrees of movement in their finger joints, variance in hand size or deformities. The developed glove is fitted with sensors to overcome these issues. This glove will help quantify joint stiffness and monitor patient progression during the arthritis rehabilitation process.

[1]  F. A. Hellebrandt,et al.  The Measurement of Joint Motion: Part III—Reliability of Goniometry , 1949 .

[2]  J. Scott Morning Stiffness in Rheumatoid Arthritis * , 1960, Annals of the rheumatic diseases.

[3]  R. J. Johns,et al.  Quantitative and Qualitative Analysis of Joint Stiffness in Normal Subjects and in Patients with Connective Tissue Diseases *† , 1961, Annals of the rheumatic diseases.

[4]  M. Ingpen,et al.  A simple apparatus for assessment of stiffness. , 1968, Annals of physical medicine.

[5]  H. Holman,et al.  Measurement of patient outcome in arthritis. , 1980, Arthritis and rheumatism.

[6]  J. Fries,et al.  The dimensions of health outcomes: the health assessment questionnaire, disability and pain scales. , 1982, The Journal of rheumatology.

[7]  A. Unsworth,et al.  Measurement of stiffness in the metacarpophalangeal joint: the arthrograph. , 1982, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[8]  V. Wright,et al.  Reference values for metacarpophalangeal joint stiffness in normals. , 1985, Annals of the rheumatic diseases.

[9]  M. Liang,et al.  The American Rheumatism Association 1987 revised criteria for the classification of rheumatoid arthritis. , 1988, Arthritis and rheumatism.

[10]  J. Drace,et al.  Evaluation of a fiber optic glove for semi-automated goniometric measurements. , 1990, Journal of rehabilitation research and development.

[11]  van der Heijde Dm,et al.  Development of a disease activity score based on judgment in clinical practice by rheumatologists. , 1993 .

[12]  M. A. van 't Hof,et al.  Development of a disease activity score based on judgment in clinical practice by rheumatologists. , 1993, The Journal of rheumatology.

[13]  Neff Walker,et al.  Evaluation of the CyberGlove as a whole-hand input device , 1995, TCHI.

[14]  D. Hose,et al.  A Goniometric Glove for Clinical Hand Assessment , 2000, Journal of hand surgery.

[15]  L. Kinzl,et al.  Reproduzierbarkeit von Fingergelenkwinkelmessungen mit einem Sensorhandschuh , 2001 .

[16]  N. Wachter,et al.  [Reproducibility of measuring the finger joint angle with a sensory glove]. , 2001, Handchirurgie, Mikrochirurgie, Plastische Chirurgie.

[17]  M. Dougados,et al.  Early referral recommendation for newly diagnosed rheumatoid arthritis: evidence based development of a clinical guide , 2002, Annals of the rheumatic diseases.

[18]  P. Dario,et al.  Evaluation of an instrumented glove for hand-movement acquisition. , 2003, Journal of rehabilitation research and development.

[19]  R. Meals,et al.  Proximal interphalangeal joint stiffness: measurement and analysis. , 2005, The Journal of hand surgery.

[20]  Lisa K Simone,et al.  Design considerations for a wearable monitor to measure finger posture , 2005, Journal of NeuroEngineering and Rehabilitation.

[21]  Derek G. Kamper,et al.  A low cost instrumented glove for extended monitoring and functional hand assessment , 2007, Journal of Neuroscience Methods.

[22]  Giovanni Saggio,et al.  A novel application method for wearable bend sensors , 2009, 2009 2nd International Symposium on Applied Sciences in Biomedical and Communication Technologies.

[23]  Joseph Classen,et al.  Development and evaluation of a low-cost sensor glove for assessment of human finger movements in neurophysiological settings , 2009, Journal of Neuroscience Methods.

[24]  W. Tharion,et al.  Interrater and intrarater reliability of finger goniometric measurements. , 2010, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[25]  Kang Li,et al.  Development of finger-motion capturing device based on optical linear encoder. , 2011, Journal of rehabilitation research and development.

[26]  Kevin Curran,et al.  Wearable rehab technology for automatic measurement of patients with arthritis , 2011, 2011 5th International Conference on Pervasive Computing Technologies for Healthcare (PervasiveHealth) and Workshops.

[27]  Kevin Curran,et al.  Novel smart sensor glove for arthritis rehabiliation , 2013, BSN.

[28]  Brendan O'Flynn,et al.  Novel Smart Glove Technology as a Biomechanical Monitoring Tool , 2015 .