The influence of bowtie filtration on x-ray photons distribution in cone beam CT

Bowtie filters are used to modulate an incoming x-ray beam as a function of the angle of the x-ray to balance the photon flux on a detector array. Because of their key roles in radiation dose reduction and multi-energy imaging, bowtie filters have attracted a major attention in modern X-ray computed tomography (CT). However, few researches are concerned on the effects of the structure and materials for the bowtie filter in the Cone Beam CT (CBCT). In this study, the influence of bowtie filters’ structure and materials on X-ray photons distribution are analyzed using Monte Carlo (MC) simulations by MCNP5 code. In the current model, the phantom was radiated by virtual X-ray source (its’ energy spectrum calculated by SpekCalc program) filtered using bowtie, then all photons were collected through array photoncounting detectors. In the process above, two bowtie filters’ parameters which include center thickness (B), edge thickness (controlled by A), changed respectively. Two kinds of situation are simulated: 1) A=0.036, B=1, 2, 3, 4, 5, 6mm and the material is aluminum; 2) A=0.016, 0.036, 0.056, 0.076, 0.096, B=2mm and the material is aluminum. All the X-ray photons' distribution are measured through MCNP. The results show that reduction in center thickness and edge thickness can reduce the number of background photons in CBCT. Our preliminary research shows that structure parameters of bowtie filter can influence X-ray photons, furthermore, radiation dose distribution, which provide some evidences in design of bowtie filter for reducing radiation dose in CBCT.

[1]  Variations in cone beam CT numbers as a function of patient size: In vivo demonstration in bladder cancer patients , 2010, Journal of medical imaging and radiation oncology.

[2]  F Verhaegen,et al.  SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes , 2009, Physics in medicine and biology.

[3]  Norbert J Pelc,et al.  The feasibility of a piecewise-linear dynamic bowtie filter. , 2013, Medical physics.

[4]  Wenxiang Cong,et al.  Dynamic Bowtie Filter for Cone-Beam/Multi-Slice CT , 2014, PloS one.

[5]  F Verhaegen,et al.  Spatial frequency spectrum of the x-ray scatter distribution in CBCT projections. , 2013, Medical physics.

[6]  F Verhaegen,et al.  The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT. , 2011, Medical physics.

[7]  D. Jaffray,et al.  The influence of bowtie filtration on cone-beam CT image quality. , 2007, Medical physics.

[8]  Michael Campbell,et al.  Medipix3: A 64 k pixel detector readout chip working in single photon counting mode with improved spectrometric performance , 2011 .

[9]  J H Siewerdsen,et al.  Compensators for dose and scatter management in cone-beam computed tomography. , 2007, Medical physics.

[10]  R. Forster,et al.  MCNP™ Version 5 , 2004 .

[11]  Ge Wang,et al.  Dynamic bowtie for fan-beam CT. , 2013, Journal of X-ray science and technology.

[12]  A. Butler,et al.  Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE , 2010, European Radiology.