Investigation of inverter-fed induction motors under fault conditions
暂无分享,去创建一个
A mathematical model based on space-vector theory is used to analyze inverter-fed induction motors faults. Inverter supply faults like an open phase fault, the failure of a transistor to switch on, the delay in a branch command, or the stand of the branch command are analyzed. These events introduce an asymmetry in the supply voltages, in the current values, and in the spatial field distribution. A detailed investigation of typical inverter supply failures is presented and discussed in order to identify remedial strategies.<<ETX>>
[1] T. J. Sobczyk,et al. Analysis of currents and an electromagnetic torque in steady states of induction squirrel-cage motors with asymmetric stator windings , 1988 .
[2] S. Williamson,et al. Analysis of Cage Induction Motors with Stator Winding Faults , 1985, IEEE Power Engineering Review.