Utilisation d'un système d'imagerie en temps réel dans le contrôle quotidien de patients traités par irradiation pour un cancer thoracique

PURPOSE: Retrospective analysis of the results obtained with daily interactive use of portal imaging for monitoring thoracic cancer radiotherapy. MATERIALS AND METHODS: A Siemens electronic portal imaging system called Beamviewplus was used daily in 15 lung cancer patients for each X-ray field. Out of the 714 expected portal images, 585 (82%), were obtained and printed. RESULTS: We counted 94 errors in the 585 successful controls (16%). Four main classes of errors were identified: irradiation field placement (47 cases, 50%), shielding placement (30 cases, 32%) patient's position on the till examining table (14 cases, 15%), and selection of the energy (3 cases, 3%). Forty percent of these errors were potentially serious in terms of treatment volume and vital organ protection. CONCLUSION: Only portal imaging control could easily detect errors because they occurred randomly. We thus consider the use of this daily system helpful for patient management.

[1]  A Fenster,et al.  Daily monitoring and correction of radiation field placement using a video-based portal imaging system: a pilot study. , 1992, International journal of radiation oncology, biology, physics.

[2]  L. Vanuytsel,et al.  Localization errors in mantle-field irradiation for Hodgkin's disease. , 1989, International journal of radiation oncology, biology, physics.

[3]  A G Visser,et al.  Performance of a prototype fluoroscopic radiotherapy imaging system. , 1990, International journal of radiation oncology, biology, physics.

[4]  A G Haus,et al.  The value of frequent treatment verification films in reducing localization error in the irradiation of complex fields , 1976, Cancer.

[5]  R. Trouette,et al.  Utilisation en routine du portal imaging électronique. Vérification de mise en place de 922 champs pelviens successifs , 1995 .

[6]  G E Hanks,et al.  Patterns of care study: Hodgkin's disease relapse rates and adequacy of portals , 1983, Cancer.

[7]  M van Herk,et al.  First clinical experience with a newly developed electronic portal imaging device. , 1990, International journal of radiation oncology, biology, physics.

[8]  W. De Neve,et al.  Clinical implementation of electronic portal imaging: correction strategies and set-up errors. , 1996, Bulletin du cancer. Radiotherapie : journal de la Societe francaise du cancer : organe de la societe francaise de radiotherapie oncologique.

[9]  M. Goitein,et al.  Accuracy of radiation field alignment in clinical practice. , 1985, International journal of radiation oncology, biology, physics.

[10]  A G Haus,et al.  Localization error in the radiotherapy of Hodgkin's disease and malignant lymphoma with extended mantle fields , 1974, Cancer.

[11]  Michael G. Herman,et al.  CLINICAL USE OF ON-LINE PORTAL IMAGING FOR DAILY PATIENT TREATMENT VERIFICATION , 1994 .

[12]  N. Mendenhall,et al.  Reproducibility of mantle irradiation with daily imaging films. , 1990, International journal of radiation oncology, biology, physics.

[13]  S. Pizer,et al.  Portal film enhancement: technique and clinical utility. , 1993, International journal of radiation oncology, biology, physics.

[14]  P. Munro,et al.  A review of electronic portal imaging devices (EPIDs). , 1992, Medical physics.

[15]  J W Denham,et al.  Objective decision-making following a portal film: the results of a pilot study. , 1993, International journal of radiation oncology, biology, physics.

[16]  M Coghe,et al.  Routine clinical on-line portal imaging followed by immediate field adjustment using a tele-controlled patient couch. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  F. Mornex L'imagerie portale, pour quoi faire ? , 1996 .

[18]  Imagerie portale. Etat de l'art en 1996. , 1996 .

[19]  P. Levendag,et al.  Accuracy of patient positioning in mantle field irradiation. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[20]  J. Cox,et al.  Weekly localization films and detection of field placement errors. , 1978, International journal of radiation oncology, biology, physics.

[21]  R K Valicenti,et al.  Is weekly port filming adequate for verifying patient position in modern radiation therapy? , 1994, International journal of radiation oncology, biology, physics.

[22]  K S Lam,et al.  On-line measurement of field placement errors in external beam radiotherapy. , 1987, The British journal of radiology.