FRET-based small-molecule fluorescent probes: rational design and bioimaging applications.

Fluorescence imaging has emerged as a powerful tool for monitoring biomolecules within the context of living systems with high spatial and temporal resolution. Researchers have constructed a large number of synthetic intensity-based fluorescent probes for bio-imaging. However, intensity-based fluorescent probes have some limitations: variations in probe concentration, probe environment, and excitation intensity may influence the fluorescence intensity measurements. In principle, the use of ratiometric fluorescent probes can alleviate this shortcoming. Förster resonance energy transfer (FRET) is one of the most widely used sensing mechanisms for ratiometric fluorescent probes. However, the development of synthetic FRET probes with favorable photophysical properties that are also suitable for biological imaging applications remains challenging. In this Account, we review the rational design and biological applications of synthetic FRET probes, focusing primarily on studies from our laboratory. To construct useful FRET probes, it is a pre-requisite to develop a FRET platform with favorable photophysical properties. The design criteria of a FRET platform include (1) well-resolved absorption spectra of the donor and acceptor, (2) well-separated emission spectra of the donor and acceptor, (3) donors and acceptors with comparable brightness, (4) rigid linkers, and (5) near-perfect efficiency in energy transfer. With an efficient FRET platform in hand, it is then necessary to modulate the donor-acceptor distance or spectral overlap integral in an analyte-dependent fashion for development of FRET probes. Herein, we emphasize our most recent progress on the development of FRET probes by spectral overlap integral, in particular by changing the molar absorption coefficient of the donor dyes such as rhodamine dyes, which undergo unique changes in the absorption profiles during the ring-opening and -closing processes. Although partial success has been obtained in design of first-generation rhodamine-based FRET probes via modulation of acceptor molar absorption coefficient, further improvements in terms of versatility, sensitivity, and synthetic accessibility are required. To address these issues with the first-generation rhodamine-based FRET probes, we have proposed a strategy for the design of second-generation probes. As a demonstration, we have developed FRET imaging probes for diverse targets including Cu²⁺, NO, HOCl, cysteine, and H₂O₂. This discussion of the methods for successfully designing synthetic FRET probes underscores the rational basis for further development of new FRET probes as a molecular toolbox for probing and manipulating a wide variety of biomolecules in living systems.

[1]  T. Muir,et al.  Synthesis of proteins by native chemical ligation. , 1994, Science.

[2]  Juyoung Yoon,et al.  A new trend in rhodamine-based chemosensors: application of spirolactam ring-opening to sensing ions. , 2008, Chemical Society reviews.

[3]  Weiying Lin,et al.  A ratiometric fluorescent probe for thiols based on a tetrakis(4-hydroxyphenyl)porphyrin-coumarin scaffold. , 2011, The Journal of organic chemistry.

[4]  Juyoung Yoon,et al.  Fluorescent chemosensors based on spiroring-opening of xanthenes and related derivatives. , 2012, Chemical reviews.

[5]  Tao Yi,et al.  FRET-based sensor for imaging chromium(III) in living cells. , 2008, Chemical communications.

[6]  Xiaoling Zhang,et al.  A ratiometric fluorescent probe based on FRET for imaging Hg2+ ions in living cells. , 2008, Angewandte Chemie.

[7]  Lin Yuan,et al.  Development of a ratiometric fluorescent sensor for ratiometric imaging of endogenously produced nitric oxide in macrophage cells. , 2011, Chemical communications.

[8]  G. Zlokarnik,et al.  Quantitation of transcription and clonal selection of single living cells with beta-lactamase as reporter. , 1998, Science.

[9]  Lin Yuan,et al.  Development of FRET-based dual-excitation ratiometric fluorescent pH probes and their photocaged derivatives. , 2012, Chemistry.

[10]  Jong Seung Kim,et al.  Metal ion induced FRET OFF-ON in tren/dansyl-appended rhodamine. , 2008, Organic letters.

[11]  Y. Urano,et al.  A novel design method of ratiometric fluorescent probes based on fluorescence resonance energy transfer switching by spectral overlap integral. , 2003, Chemistry.

[12]  G. Shen,et al.  Efficient fluorescence resonance energy transfer-based ratiometric fluorescent cellular imaging probe for Zn(2+) using a rhodamine spirolactam as a trigger. , 2010, Analytical chemistry.

[13]  Lin Yuan,et al.  Construction of a FRET-based ratiometric fluorescent thiol probe. , 2011, Chemical communications.

[14]  D. Domaille,et al.  Corrigendum: Synthetic fluorescent sensors for studying the cell biology of metals , 2008 .

[15]  P. Choyke,et al.  New strategies for fluorescent probe design in medical diagnostic imaging. , 2010, Chemical reviews.

[16]  Igor L. Medintz,et al.  Materials for Fluorescence Resonance Energy Transfer Analysis: Beyond Traditional Donor—Acceptor Combinations , 2006 .

[17]  C. Afonso,et al.  Synthesis and Applications of Rhodamine Derivatives as Fluorescent Probes , 2009 .

[18]  K. Kikuchi,et al.  Recent advances in the design of small molecule-based FRET sensors for cell biology , 2004 .

[19]  T. Nagano,et al.  Fluorescent probes for sensing and imaging , 2011, Nature Methods.

[20]  Lin Yuan,et al.  A Fluorescent Cobalt Probe with a Large Ratiometric Fluorescence Response via Modulation of Energy Acceptor Molar Absorptivity on Metal Ion Binding , 2008 .

[21]  Christopher J. Chang,et al.  A FRET-based approach to ratiometric fluorescence detection of hydrogen peroxide. , 2006, Journal of the American Chemical Society.

[22]  T. Duong,et al.  Fluoro- and chromogenic chemodosimeters for heavy metal ion detection in solution and biospecimens. , 2010, Chemical reviews.

[23]  Lin Yuan,et al.  A native-chemical-ligation-mechanism-based ratiometric fluorescent probe for aminothiols. , 2012, Chemistry.

[24]  Lin Yuan,et al.  Fluorescent detection of hypochlorous acid from turn-on to FRET-based ratiometry by a HOCl-mediated cyclization reaction. , 2012, Chemistry.

[25]  Lin Yuan,et al.  Development of FRET-based ratiometric fluorescent Cu2+ chemodosimeters and the applications for living cell imaging. , 2012, Organic letters.

[26]  A. W. Czarnik,et al.  A LONG-WAVELENGTH FLUORESCENT CHEMODOSIMETER SELECTIVE FOR CU(II) ION IN WATER , 1997 .

[27]  G. Bazan Novel organic materials through control of multichromophore interactions. , 2007, The Journal of organic chemistry.

[28]  Dylan W Domaille,et al.  Synthetic fluorescent sensors for studying the cell biology of metals. , 2008, Nature chemical biology.

[29]  Th. Förster Zwischenmolekulare Energiewanderung und Fluoreszenz , 1948 .

[30]  A. Demchenko The Concept of λ-Ratiometry in Fluorescence Sensing and Imaging , 2010, Journal of Fluorescence.

[31]  Weiying Lin,et al.  Ratio-Au: a FRET-based fluorescent probe for ratiometric determination of gold ions and nanoparticles. , 2011, Chemistry.

[32]  Evan W. Miller,et al.  An ICT-based approach to ratiometric fluorescence imaging of hydrogen peroxide produced in living cells. , 2008, Journal of the American Chemical Society.

[33]  Juyoung Yoon,et al.  Highly selective fluorescent probe for Au3+ based on cyclization of propargylamide. , 2009, Chemical communications.

[34]  Lin Yuan,et al.  Single fluorescent probe responds to H2O2, NO, and H2O2/NO with three different sets of fluorescence signals. , 2012, Journal of the American Chemical Society.