Impact of mechanical and biological aortic valve replacement on coronary perfusion: a prospective, randomized study.

BACKGROUND AND AIM OF THE STUDY Coronary perfusion is impaired in patients with aortic stenosis (AS). Aortic valve replacement (AVR) leads to improvement, but not complete restoration, of coronary flow. Previous studies have shown that postoperative coronary flow rate and coronary reserve in mechanical valves is dependent on valve design and orientation. The study aim was to investigate acute changes in coronary perfusion in patients undergoing mechanical or biological valve replacement in a prospective, randomized clinical study. METHODS Forty patients undergoing AVR for AS underwent MRI scanning to measure coronary flow preoperatively and at five days after surgery. Patients scheduled for mechanical AVR (n = 20) were randomized to a tilting disc (Medtronic Hall) or bileaflet (Medtronic ADVANTAGE) prosthesis; the biological-valve group (n = 20) received a stented (Medtronic Mosaic) or stentless (Medtronic Freestyle) valve. Valve sizes were comparable in all groups. Patients also underwent echocardiography both preoperatively and postoperatively to measure transvalvular pressure gradients. The rate-pressure product (RPP) was calculated as a marker of myocardial oxygen demand and cardiac workload. RESULTS The mean preoperative coronary flow rate was 90 +/- 32 ml/min, and this increased after AVR in all patients. The rise in the mechanical-valve groups was comparable for the two tested valves, whereas in the biological-valve groups a significantly higher increase for stentless valves was present (p < 0.05). Mean pressure gradients for the Hall and ADVANTAGE valves were equal; for biological valves, the Mosaic demonstrated a higher mean gradient (19 +/- 6 mmHg) than the Freestyle (10 +/- 4 mmHg) (p < 0.05). The RPP was lower for ADVANTAGE (mechanical group) and for Freestyle valves (biological group). CONCLUSION Coronary artery flow was increased following AVR in all valve groups. The rise was significantly more distinct for Medtronic Freestyle stentless valves compared to the three other valve substitutes. As the stentless design also demonstrated superior hemodynamics and a lower myocardial oxygen demand with lower pressure gradients and lower RPP, this may have a positive impact on the clinical long-term outcome of this valve.

[1]  G. Grunkemeier,et al.  Twenty years' experience with the Medtronic Hall valve. , 2001, The Journal of thoracic and cardiovascular surgery.

[2]  Komarakshi R Balakrishnan,et al.  Further insights into normal aortic valve function: role of a compliant aortic root on leaflet opening and valve orifice area. , 2004, The Annals of thoracic surgery.

[3]  S. Armstrong,et al.  Late results of heart valve replacement with the Hancock II bioprosthesis. , 2001, The Journal of thoracic and cardiovascular surgery.

[4]  C. Higgins,et al.  Assessment of coronary flow velocity reserve using fast velocity-encoded cine MRI for noninvasive detection of restenosis after coronary stent implantation. , 2001, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[5]  P K Paulsen,et al.  Quantitation of the turbulent stress distribution downstream of normal, diseased and artificial aortic valves in humans. , 1992, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.