Single-angle reflectance spectroscopy to determine the optical constants n and k: considerations in the far-infrared domain.

Single-angle infrared (IR) reflectance spectroscopy is a proven and effective method for determining the complex optical constants n and k of condensed matter. The modern method uses a Fourier transform IR spectrometer to record the quantitative reflectance R(ν) spectra followed by application of the Kramers-Kronig transform (KKT) to obtain the complex optical constants. In order to carry out the KKT, it is essential to measure the reflectance spectra to as high and low a frequency (wavenumber) as possible. Traditionally, the reflectance spectra of solid specimens consist of large (typically>10  mm diameter) polished single-crystal faces free of defects or voids. The requirement of a large polished face, however, is not a realistic expectation for many synthetic, geologic, or rare specimens where the size is usually small and the morphology can vary. In this paper we discuss several improvements and considerations to both the hardware and far-IR measurement protocols that lead to more accurate R(ν) values and thus to more accurate n/k values, especially for small (millimeter-sized) specimens where the R(ν) spectrum is concatenated from multiple independent R(ν) spectra from overlapping hardware/spectral domains. Specifically, the improved hardware and analyses introduced here include the following: (1) providing a set of far-IR calibration standards; (2) custom-designing and manufacturing low reflectivity, stray-light reducing sample masks for small specimens; (3) minimizing stray light interaction between the sample mask, the interferometer Jacquinot stop, and the detector; (4) optimizing the methods to "splice" together the spectra from independent domains; (5) discussing what methods one can use to obtain or calculate the important R(0  cm-1) value; (6) using a quartic relationship to extrapolate from the measured R data to R(0); and (7) accounting for the limiting effects of diffraction for the spot size at the sample mask and detector for millimeter-sized specimens, especially at the very long wavelengths. These seven considerations are all highly interconnected and are discussed in turn, as well as their strong interdependencies. This paper presents a holistic approach for determining reliable n/k values of millimeter-sized samples using single-angle reflectance in the mid- and far-IR.

[1]  Toya N. Beiswenger,et al.  Identification of Uranium Minerals in Natural U-Bearing Rocks Using Infrared Reflectance Spectroscopy , 2018, Applied spectroscopy.

[2]  Hiroshi Suga,et al.  Dielectric study of CH3NH3PbX3 (X = Cl, Br, I) , 1992 .

[3]  C E Lund Myhre,et al.  Optical constants of HNO3/H2O and H2SO4/HNO3/H2O at low temperatures in the infrared region. , 2005, The journal of physical chemistry. A.

[4]  T. Johnson,et al.  Gas-Phase Databases for Quantitative Infrared Spectroscopy , 2004, Applied spectroscopy.

[5]  S. Twomey,et al.  Spectral Reflectance of Clouds in the Near-Infrared: Comparison of Measurements and Calculations , 1982 .

[6]  Thomas A Blake,et al.  Absolute integrated intensities of vapor-phase hydrogen peroxide (H2O2) in the mid-infrared at atmospheric pressure , 2009, Analytical and bioanalytical chemistry.

[7]  R. A. Parker,et al.  Static Dielectric Constant of Rutile (TiO2), 1.6-1060°K , 1961 .

[8]  M. J. Persky Review of black surfaces for space-borne infrared systems , 1999 .

[9]  Timothy J. Johnson,et al.  Quantitative infrared intensity studies of vapor-phase glyoxal, methylglyoxal, and 2,3-butanedione (diacetyl) with vibrational assignments. , 2011, The journal of physical chemistry. A.

[10]  Claus J. Nielsen,et al.  Spectroscopic Study of Aqueous H2SO4 at Different Temperatures and Compositions: Variations in Dissociation and Optical Properties , 2003 .

[11]  D. Smith,et al.  Optical constants of far infrared materials. 2: crystalline solids. , 1973, Applied optics.

[12]  Yin-Fong Su,et al.  Intensity-Value Corrections for Integrating Sphere Measurements of Solid Samples Measured behind Glass , 2014, Applied spectroscopy.

[13]  Ely E. Bell,et al.  Measurement of the optical constants of crystal quartz in the far infrared with the asymmetric Fourier-transform method , 1967 .

[14]  Eunja Kim,et al.  Time-Resolved Infrared Reflectance Studies of the Dehydration-Induced Transformation of Uranyl Nitrate Hexahydrate to the Trihydrate Form. , 2015, The journal of physical chemistry. A.

[15]  W. S. Graswinckel,et al.  Optical Response of High-Dielectric-Constant Perovskite-Related Oxide , 2001, Science.

[16]  T. L. Myers,et al.  Accurate Measurement of the Optical Constants n and k for a Series of 57 Inorganic and Organic Liquids for Optical Modeling and Detection , 2017, Applied spectroscopy.

[17]  Jerzy Krupka,et al.  Dielectric characterization of low-loss materials a comparison of techniques , 1998 .

[18]  Thomas A Blake,et al.  Removing aperture-induced artifacts from Fourier transform infrared intensity values. , 2002, Applied optics.

[19]  Tanya L. Myers,et al.  Complex refractive index measurements for BaF 2 and CaF 2 via single-angle infrared reflectance spectroscopy , 2017 .

[20]  Timothy J. Johnson,et al.  An infrared spectral database for detection of gases emitted by biomass burning , 2010 .

[21]  Timothy J. Johnson,et al.  The quantitative infrared and NIR spectrum of CH 2 I 2 vapor: vibrational assignments and potential for atmospheric monitoring , 2006 .

[22]  K. F. Young,et al.  Compilation of the Static Dielectric Constant of Inorganic Solids , 1973 .

[23]  D. Aspnes Chapter 5 – The Accurate Determination of Optical Properties by Ellipsometry , 1985 .

[24]  D. Roessler,et al.  Kramers-Kronig analysis of reflection data , 1965 .

[25]  Tanya L. Myers,et al.  Infrared reflectance spectra: effects of particle size, provenance and preparation , 2014, Security and Defence.

[26]  J. H. Weaver,et al.  Optical constants of Cu, Ag, and Au revisited , 2015 .

[27]  P. Maddalena,et al.  Optical properties of graphene oxide and reduced graphene oxide determined by spectroscopic ellipsometry , 2017 .

[28]  J. Woollam,et al.  Determination of the mid-IR optical constants of water and lubricants using IR ellipsometry combined with an ATR cell , 1998 .

[29]  L. Mertz Correction of Phase Errors in Interferograms , 1963 .

[30]  U. Waghmare,et al.  Effects of Zr and Ti doping on the dielectric response of CeO2: A comparative first-principles study , 2010 .

[31]  E. V. Loewenstein,et al.  Optical constants of far infrared materials. 3: plastics. , 1975, Applied optics.

[32]  S. Hook,et al.  The ASTER spectral library version 2.0 , 2009 .

[33]  Alfredo Pasquarello,et al.  Dielectric constants of Zr silicates: a first-principles study. , 2002, Physical review letters.

[34]  Yin-Fong Su,et al.  Quantitative reflectance spectra of solid powders as a function of particle size. , 2015, Applied optics.

[35]  Toya N. Beiswenger,et al.  Synthesis, electronic transport and optical properties of Si:α-Fe2O3 single crystals , 2016 .

[36]  Timothy J. Johnson,et al.  Quantitative infrared and near-infrared gas-phase spectra for pyridine: Absolute intensities and vibrational assignments , 2018 .

[37]  Timothy J. Johnson,et al.  Mid-infrared versus far-infrared (THz) relative intensities of room-temperature Bacillus spores , 2005 .

[38]  D. Smith,et al.  Optical constants of far infrared materials. I: analysis of channeled spectra and application to mylar. , 1971, Applied optics.

[39]  S M Smith,et al.  Specular reflectance of optical-black coatings in the far infrared. , 1984, Applied optics.

[40]  James N. Hilfiker,et al.  Survey of methods to characterize thin absorbing films with Spectroscopic Ellipsometry , 2008 .

[41]  Bruce Hapke,et al.  Applications of an Energy Transfer Model to Three Problems in Planetary Regoliths: The Solid-State Greenhouse, Thermal Beaming, and Emittance Spectra , 1996 .

[42]  R. Kleim,et al.  Systematic errors in rotating-compensator ellipsometry , 1994 .