Controller design with model identification approach in wide area power system

Using wide area monitoring systems (WAMS) offers a possibility for an integrated measurement-based and model-based control, which suits to the operation of large electric power system (EPS), along with online analysis. This paper presents studies on a model identification approach with the use of synchronous measurement data to represent an equivalent system. Firstly, in the study, the coherent generators in each area of large EPS are determined by the mutual information theory. Then, state-space two-input two-output models are identified for a single generator representing the coherent area. The model identification algorithms; least-square (LS), instrumental variable (IV) and subspace state-space (N4SID) based generalized Poisson moment function (GPMF) are used. Finally, the controller is designed with the identified model at WAMS level by reducing the H∞ norm of its closed loop transfer function as much as possible. The centralized controller at WAMS level is demonstrated to stabilize the speed deviations of each generator between any two areas in the large EPS. The study is investigated with different input signal variable excited by different pattern of under disturbances.

[1]  I. C. Decker,et al.  Wide-Area Measurements-Based Two-Level Control Design Considering Signal Transmission Delay , 2009, IEEE Transactions on Power Systems.

[2]  Alireza Soroudi,et al.  Probabilistic determination of pilot points for zonal voltage control , 2012 .

[3]  H. Unbehauen,et al.  Identification of continuous-time systems , 1991 .

[4]  Hugues Garnier,et al.  The CONTSID toolbox for Matlab: extensions and latest developments , 2009 .

[5]  Chao Lu,et al.  Optimal Coordinate Design of Multiple HVDC Modulation Controllers based on MIMO System Identification , 2007, 2007 IEEE Power Engineering Society General Meeting.

[6]  Michael L. Overton,et al.  H∞ strong stabilization via HIFOO, a package for fixed-order controller design , 2008, 2008 47th IEEE Conference on Decision and Control.

[7]  Young-Moon Park,et al.  The modal performance measure for parameter optimization of power system stabilizers , 1993 .

[8]  Balarko Chaudhuri,et al.  Wide-area measurement-based stabilizing control of power system considering signal transmission delay , 2004 .

[9]  H. Ghasemi,et al.  Oscillatory stability limit prediction using stochastic subspace identification , 2006, IEEE Transactions on Power Systems.

[10]  Ke Luo,et al.  Wide-area damping controller based on model prediction and sliding mode control , 2010, 2010 8th World Congress on Intelligent Control and Automation.

[11]  Aranya Chakrabortty,et al.  Wide-Area Damping Control of Power Systems Using Dynamic Clustering and TCSC-Based Redesigns , 2012, IEEE Transactions on Smart Grid.

[12]  L. Flores,et al.  Tuning of power system stabilizers using optimization techniques , 1991, IEEE Power Engineering Review.

[13]  Ning Zhou,et al.  Initial results in power system identification from injected probing signals using a subspace method , 2006, IEEE Transactions on Power Systems.

[14]  N.W. Miller,et al.  Identification of equivalent linear power system models from electromagnetic transient time domain simulations using Prony's method , 1996, Proceedings of 35th IEEE Conference on Decision and Control.

[15]  N. W. Miller,et al.  Identifying linear models from time domain simulations , 1997 .

[16]  R. Feuillet,et al.  System protection scheme for mitigation of cascaded voltage collapses , 2009 .

[17]  G. Trudel,et al.  Low-order black-box models for control system design in large power systems , 1995, Proceedings of Power Industry Computer Applications Conference.

[18]  Nand Kishor,et al.  Fuzzy modeling of fuel cell based on mutual information between variables , 2010 .

[19]  R Eriksson,et al.  Wide-Area Measurement System-Based Subspace Identification for Obtaining Linear Models to Centrally Coordinate Controllable Devices , 2011, IEEE Transactions on Power Delivery.

[20]  B. Chaudhuri,et al.  Robust damping of multiple swing modes employing global stabilizing signals with a TCSC , 2004, IEEE Transactions on Power Systems.

[21]  Nand Kishor,et al.  Fixed-order controller for reduced-order model for damping of power oscillation in wide area network , 2013, 2013 IEEE Grenoble Conference.

[22]  Ganesh K. Venayagamoorthy,et al.  Real-time implementation of a measurement-based adaptive wide-area control system considering communication delays , 2008 .

[23]  Pierre Apkarian,et al.  Nonsmooth H∞ synthesis , 2005, IEEE Trans. Autom. Control..

[24]  V. A. Maslennikov,et al.  Method and software for coordinated tuning of power system regulators , 1997 .

[25]  Nilanjan Ray Chaudhuri,et al.  Damping Control in Power Systems Under Constrained Communication Bandwidth: A Predictor Corrector Strategy , 2012, IEEE Transactions on Control Systems Technology.

[26]  I. C. Decker,et al.  Design of power system controllers by nonsmooth, nonconvex optimization , 2009, 2009 IEEE Power & Energy Society General Meeting.

[27]  B. C. Papadias,et al.  Power System Stabilization via Parameter Optimization - Application to the Hellenic Interconnected System , 1987, IEEE Transactions on Power Systems.

[28]  A. Simoes Costa,et al.  Design of decentralized controllers for large power systems considering sparsity , 1997 .

[29]  L. Vanfretti,et al.  Estimation of Radial Power System Transfer Path Dynamic Parameters Using Synchronized Phasor Data , 2008, IEEE Transactions on Power Systems.

[30]  Jukka Turunen,et al.  Controller design with model identification approach in wide area power system , 2014 .

[31]  Peng Zhang,et al.  Adaptive wide-area damping control scheme with stochastic subspace identification and signal time delay compensation , 2012 .

[32]  Vaithianathan Venkatasubramanian,et al.  Wide-area monitoring and control algorithms for large power systems using synchrophasors , 2009, 2010 IREP Symposium Bulk Power System Dynamics and Control - VIII (IREP).

[33]  B. C. Pal,et al.  Robust damping of interarea oscillations with unified power-flow controller , 2002 .

[34]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[35]  Ying-Yi Hong,et al.  A new approach using optimization for tuning parameters of power system stabilizers , 1999 .

[36]  Donald A. Pierre,et al.  Robust power system controller design based on measured models , 1996 .

[37]  Ning Zhou,et al.  Performance of Three Mode-Meter Block-Processing Algorithms for Automated Dynamic Stability Assessment , 2008, IEEE Transactions on Power Systems.

[38]  Innocent Kamwa,et al.  Robust design and coordination of multiple damping controllers using nonlinear constrained optimization , 1999 .

[39]  Adrian S. Lewis,et al.  HIFOO - A MATLAB package for fixed-order controller design and H ∞ optimization , 2006 .

[40]  Tetsuya Iwasaki,et al.  The dual iteration for fixed-order control , 1999, IEEE Trans. Autom. Control..

[41]  W. Marsden I and J , 2012 .

[42]  M. Dehghani,et al.  State-Space Model Parameter Identification in Large-Scale Power Systems , 2008, IEEE Transactions on Power Systems.

[43]  A. Kraskov,et al.  Estimating mutual information. , 2003, Physical review. E, Statistical, nonlinear, and soft matter physics.

[44]  Innocent Kamwa,et al.  State-space system identification-toward MIMO models for modal analysis and optimization of bulk power systems , 2000 .