Measuring 3D indoor air velocity via an inexpensive low-power ultrasonic anemometer
暂无分享,去创建一个
Therese Peffer | Hui Zhang | Paul Raftery | Michael P. Andersen | Edward Arens | Ali Ghahramani | Megan Zhu | Richard Przybyla | Syung Min | Richard J. Przybyla | Michael P. Andersen | Vy Luu | Hui Zhang | E. Arens | P. Raftery | A. Ghahramani | Therese E. Peffer | Syung Min | M. Zhu | V. Luu
[1] A. Smedman,et al. Accuracy of Sonic Anemometers: Laminar Wind-Tunnel Calibrations Compared to Atmospheric In Situ Calibrations Against a Reference Instrument , 2004 .
[2] T. Meyers,et al. Reply to the Comment by Mauder on “How Well Can We Measure the Vertical Wind Speed? Implications for Fluxes of Energy and Mass” , 2013, Boundary-Layer Meteorology.
[3] Baisong Ning,et al. Ceiling fan air speeds around desks and office partitions , 2017 .
[4] Manuel Gameiro da Silva,et al. Accuracy Limitations for Low-Velocity Measurements and Draft Assessment in Rooms , 2007 .
[5] Chao Guo,et al. Ultrasonic Wind Velocity Measurement Based on Phase Discrimination Technique , 2012 .
[6] Edward Arens,et al. Detailed experimental investigation of air speed field induced by ceiling fans , 2018, Building and Environment.
[7] D.V. Thiel,et al. Self Heated Thermo-Resistive Element Hot Wire Anemometer , 2010, IEEE Sensors Journal.
[8] H. H. Bruun,et al. Hot-Wire Anemometry: Principles and Signal Analysis , 1996 .
[9] M. Zeeman,et al. Field intercomparison of prevailing sonic anemometers , 2017 .
[10] Bernhard E. Boser,et al. 3D Ultrasonic Rangefinder on a Chip , 2015, IEEE Journal of Solid-State Circuits.
[11] Arsen Krikor Melikov,et al. Indoor Environmental Quality ( IEQ ) Title Energy saving and improved comfort by increased air movement , 2008 .
[12] Alex Parkinson,et al. Continuous IEQ monitoring system: Context and development , 2019, Building and Environment.
[13] Edward Arens,et al. Eliminating Overcooling Discomfort While Saving Energy , 2019 .
[14] Richard J. Przybyla,et al. In-Air Rangefinding With an AlN Piezoelectric Micromachined Ultrasound Transducer , 2011, IEEE Sensors Journal.
[15] David E. Culler,et al. System Architecture Directions for Post-SoC/32-bit Networked Sensors , 2018, SenSys.
[16] William J. Massman,et al. All Sonic Anemometers Need to Correct for Transducer and Structural Shadowing in Their Velocity Measurements , 2016 .
[17] Edward Arens,et al. Indoor environmental quality assessment models: A literature review and a proposed weighting and classification scheme , 2013 .
[18] T. W. Horst,et al. Correction of a Non-orthogonal, Three-Component Sonic Anemometer for Flow Distortion by Transducer Shadowing , 2015, Boundary-Layer Meteorology.
[19] Gail Brager,et al. Air movement preferences observed in office buildings , 2007, International journal of biometeorology.
[20] Alex Parkinson,et al. Continuous IEQ monitoring system: Performance specifications and thermal comfort classification , 2019, Building and Environment.
[21] A K Melikov,et al. Advanced air distribution: improving health and comfort while reducing energy use. , 2016, Indoor air.
[22] Sekwang Park,et al. Two-dimensional ultrasonic anemometer using the directivity angle of an ultrasonic sensor , 2008, Microelectron. J..
[23] J. Toftum,et al. Air movement--good or bad? , 2004, Indoor air.
[24] F. Fiedler,et al. The Influence of the Sensor Design on Wind Measurements with Sonic Anemometer Systems , 2001 .
[25] Hui Zhang,et al. Measuring Air Speed With a Low-Power MEMS Ultrasonic Anemometer via Adaptive Phase Tracking , 2019, IEEE Sensors Journal.