Microelectromechanical systems and nephrology: the next frontier in renal replacement technology.
暂无分享,去创建一个
[1] Robert Langer,et al. A BioMEMS review: MEMS technology for physiologically integrated devices , 2004, Proceedings of the IEEE.
[2] W. Wijns,et al. Chronic monitoring of pulmonary artery pressure in patients with severe heart failure: multicentre experience of the monitoring Pulmonary Artery Pressure by Implantable device Responding to Ultrasonic Signal (PAPIRUS) II study , 2009, Heart.
[3] Mark G. Allen,et al. Hollow metal microneedles for insulin delivery to diabetic rats , 2005, IEEE Transactions on Biomedical Engineering.
[4] Edward F Leonard,et al. Membraneless dialysis--is it possible? , 2005, Contributions to nephrology.
[5] Kaweh Mansouri,et al. Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma , 2011, British Journal of Ophthalmology.
[6] G. Kost,et al. Point-of-Care Testing: Millennium Technology for Critical Care , 2000 .
[7] O. Sakowitz,et al. Intracranial pressure telemetry: first experience of an experimental in vivo study using a new device. , 2012, Acta neurochirurgica. Supplement.
[8] Mehmet Fatih Yanik,et al. Microfluidic system for on-chip high-throughput whole-animal sorting and screening at subcellular resolution , 2007, Proceedings of the National Academy of Sciences.
[9] E. Leonard,et al. Innovation in the Treatment of Uremia: Proceedings from the Cleveland Clinic Workshop: Technical Approaches Toward Ambulatory ESRD Therapy , 2009, Seminars in dialysis.
[10] G. Whitesides,et al. Soft Lithography. , 1998, Angewandte Chemie.
[11] L. J. Giling,et al. Anisotropic Etching of Crystalline Silicon in Alkaline Solutions , 2005 .
[12] Shuvo Roy,et al. Development of continuous implantable renal replacement: past and future. , 2007, Translational research : the journal of laboratory and clinical medicine.
[13] Catherine Situma,et al. Merging microfluidics with microarray-based bioassays. , 2006, Biomolecular engineering.
[14] Nigel A. Surridge,et al. The Technology Behind Glucose Meters: Test Strips , 2008 .
[15] F.A. Miranda,et al. RF telemetry system for an implantable bio-MEMS sensor , 2004, 2004 IEEE MTT-S International Microwave Symposium Digest (IEEE Cat. No.04CH37535).
[16] Mark G. Allen,et al. Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies , 2003, Proceedings of the National Academy of Sciences of the United States of America.
[17] M. Mehregany,et al. Integrated fabrication of polysilicon mechanisms , 1988 .
[18] J. Conti,et al. Reducing Events in Patients with Chronic Heart Failure (REDUCEhf ) Study Design: Continuous Hemodynamic Monitoring with an Implantable Defibrillator , 2007, Clinical cardiology.
[19] M. Staples,et al. Long-term Stability and in vitro Release of hPTH(1–34) from a Multi-reservoir Array , 2008, Pharmaceutical Research.
[20] R. Garrick,et al. A wearable haemodialysis device for patients with end-stage renal failure: a pilot study , 2008 .
[21] A. Fleischman,et al. Permeability - Selectivity Analysis for Ultrafiltration: Effect of Pore Geometry. , 2010, Journal of membrane science.
[22] P Wilding,et al. Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzer. , 1993, Clinical chemistry.
[23] Robert Langer,et al. First-in-Human Testing of a Wirelessly Controlled Drug Delivery Microchip , 2012, Science Translational Medicine.
[24] S. Quake,et al. Microfluidic Large-Scale Integration , 2002, Science.
[25] Göran Stemme,et al. Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer , 2003 .
[26] André Mermoud,et al. Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes , 2009, Acta ophthalmologica.
[27] Michael J Cima,et al. Microsystem technologies for medical applications. , 2011, Annual review of chemical and biomolecular engineering.
[28] Rodney A. White,et al. Initial results of wireless pressure sensing for endovascular aneurysm repair: the APEX Trial--Acute Pressure Measurement to Confirm Aneurysm Sac EXclusion. , 2007, Journal of vascular surgery.
[29] Ming Lei,et al. Hard and soft micromachining for BioMEMS: review of techniques and examples of applications in microfluidics and drug delivery. , 2004, Advanced drug delivery reviews.
[30] D. Menon,et al. Intracranial pressure: why we monitor it, how to monitor it, what to do with the number and what's the future? , 2011, Current opinion in anaesthesiology.
[31] H. C. Fan,et al. Erratum: Non-invasive prenatal measurement of the fetal genome , 2012, Nature.
[32] John T Santini,et al. Electrothermally activated microchips for implantable drug delivery and biosensing. , 2005, Journal of controlled release : official journal of the Controlled Release Society.
[33] William T. Abraham,et al. Direct Left Atrial Pressure Monitoring in Ambulatory Heart Failure Patients: Initial Experience With a New Permanent Implantable Device , 2007, Circulation.
[34] Hans-Dietrich Polaschegg,et al. Continuous Renal Replacement Therapy for End-Stage Renal Disease , 2005 .
[35] Mauro Ferrari,et al. Release of Biologically Functional Interferon-Alpha from a Nanochannel Delivery System , 2005, Biomedical microdevices.
[36] Joachim Boldt,et al. Clinical review: Hemodynamic monitoring in the intensive care unit , 2002, Critical care.
[37] M. Shephard. Point-of-Care Testing and Creatinine Measurement. , 2011, The Clinical biochemist. Reviews.
[38] R. Bourge,et al. A wireless pressure sensor for monitoring pulmonary artery pressure in advanced heart failure: initial experience. , 2007, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.
[39] A. Bhatia,et al. Neuromonitoring in the intensive care unit. , 2012 .
[40] Samuel K Sia,et al. Commercialization of microfluidic point-of-care diagnostic devices. , 2012, Lab on a chip.
[41] Xin Liu,et al. An Inductively Powered Implantable Blood Flow Sensor Microsystem for Vascular Grafts , 2012, IEEE Transactions on Biomedical Engineering.
[42] Stephen R Quake,et al. Microfluidic single-cell mRNA isolation and analysis. , 2006, Analytical chemistry.
[43] M. Zile,et al. Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure: the COMPASS-HF study. , 2008, Journal of the American College of Cardiology.
[44] L. Gervais,et al. Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates. , 2009, Lab on a chip.
[45] Rainer Laur,et al. Advanced hybrid integrated low-power telemetric pressure monitoring system for biomedical applications , 2000, Proceedings IEEE Thirteenth Annual International Conference on Micro Electro Mechanical Systems (Cat. No.00CH36308).
[46] J. Kaufman,et al. Aortic aneurysm sac pressure measurements after endovascular repair using an implantable remote sensor: initial experience and short-term follow-up , 2008, European Radiology.
[47] David B. N. Lee,et al. A peritoneal-based automated wearable artificial kidney , 2008, Clinical and Experimental Nephrology.
[48] H. Coakham,et al. Telemetric Implantable Pressure Sensor for Short- and Long-Term Monitoring of Intracranial Pressure , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[49] Ismail Emre Araci,et al. Microfluidic very large scale integration (mVLSI) with integrated micromechanical valves. , 2012, Lab on a chip.
[50] Yu-Chong Tai,et al. Integrated movable micromechanical structures for sensors and actuators , 1988 .
[51] K. Bean,et al. Anisotropic etching of silicon , 1978, IEEE Transactions on Electron Devices.
[52] E. Chanie,et al. On-line monitoring of urea using enzymatic field effect transistors , 2011 .
[53] Stephen R Quake,et al. Solving the "world-to-chip" interface problem with a microfluidic matrix. , 2003, Analytical chemistry.
[54] Geoffrey T. Manley,et al. VII. Intracranial Pressure Monitoring Technology , 2007 .
[55] M. Addis,et al. First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms. , 2004, Journal of vascular surgery.
[56] Stefan Welschehold,et al. First Clinical Results With a New Telemetric Intracranial Pressure-Monitoring System , 2012, Neurosurgery.
[57] G. Whitesides,et al. Soft lithography in biology and biochemistry. , 2001, Annual review of biomedical engineering.
[58] John T Santini,et al. Chronic, programmed polypeptide delivery from an implanted, multireservoir microchip device , 2006, Nature Biotechnology.
[59] P. K. Jensen,et al. In vitro measurement of corneal strain, thickness, and curvature using digital image processing. , 2009, Acta ophthalmologica Scandinavica.
[60] D. Maillefer,et al. A high-performance silicon micropump for an implantable drug delivery system , 1999, Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291).
[61] Yoseph Rozenman,et al. Wireless acoustic communication with a miniature pressure sensor in the pulmonary artery for disease surveillance and therapy of patients with congestive heart failure. , 2007, Journal of the American College of Cardiology.
[62] William T. Abraham,et al. Physician-Directed Patient Self-Management of Left Atrial Pressure in Advanced Chronic Heart Failure , 2010, Circulation.
[63] G. Whitesides,et al. Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.
[64] Sharon Grant,et al. Evaluation of the i-STAT Portable Clinical Analyzer for point-of-care blood testing in the intensive care units of a university children's hospital. , 2002, Annals of clinical and laboratory science.
[65] Joseph A Potkay,et al. Long term, implantable blood pressure monitoring systems , 2008, Biomedical microdevices.
[66] Robert N Weinreb,et al. Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma. , 2012, Archives of ophthalmology.
[67] A. Bhatia,et al. Neuromonitoring in the intensive care unit. I. Intracranial pressure and cerebral blood flow monitoring , 2007, Intensive Care Medicine.
[68] Thomas A Golper,et al. Technical breakthroughs in the wearable artificial kidney (WAK). , 2009, Clinical journal of the American Society of Nephrology : CJASN.
[69] S. Saati,et al. An electrochemical intraocular drug delivery device , 2007 .
[70] Brian K. Paul,et al. Micro Energy and Chemical Systems (MECS) and Multiscale Fabrication , 2006 .
[71] Yu Zhou,et al. Current micropump technologies and their biomedical applications , 2009 .
[72] N. Chronis,et al. A Near-Infrared Optomechanical Intracranial Pressure Microsensor , 2012, Journal of Microelectromechanical Systems.
[73] William H. Grover,et al. Development and evaluation of a microdevice for amino acid biomarker detection and analysis on Mars. , 2005, Proceedings of the National Academy of Sciences of the United States of America.
[74] Shuvo Roy,et al. High-Performance Silicon Nanopore Hemofiltration Membranes. , 2009, Journal of membrane science.
[75] A. Fleischman,et al. Implanted renal replacement for end-stage renal disease. , 2011, Panminerva medica.
[76] G. Kay,et al. Implant Experience with an Implantable Hemodynamic Monitor for the Management of Symptomatic Heart Failure , 2005, Pacing and clinical electrophysiology : PACE.
[77] P. van Damme,et al. Safety and efficacy of a novel microneedle device for dose sparing intradermal influenza vaccination in healthy adults. , 2009, Vaccine.
[78] A. Davenport,et al. Beta2-microglobulin and phosphate clearances using a wearable artificial kidney: a pilot study. , 2009, American journal of kidney diseases : the official journal of the National Kidney Foundation.
[79] R.E. Simons,et al. Wearable Wireless Telemetry System for Implantable Bio-MEMS Sensors , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.
[80] Jessica Melin,et al. Microfluidic large-scale integration: the evolution of design rules for biological automation. , 2007, Annual review of biophysics and biomolecular structure.
[81] G. Whitesides,et al. Fabrication of microfluidic systems in poly(dimethylsiloxane) , 2000, Electrophoresis.
[82] Michael R Pinsky,et al. Hemodynamic evaluation and monitoring in the ICU. , 2007, Chest.
[83] Philip Adamson,et al. Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: a multicenter, 12-month follow-up study of patients with chronic heart failure. , 2002, Journal of cardiac failure.
[84] G. Kovacs,et al. Bulk micromachining of silicon , 1998, Proc. IEEE.
[85] L. Hood,et al. Integrated barcode chips for rapid, multiplexed analysis of proteins in microliter quantities of blood , 2008, Nature Biotechnology.
[86] Kwok-Hung Chan,et al. Dose sparing intradermal trivalent influenza (2010/2011) vaccination overcomes reduced immunogenicity of the 2009 H1N1 strain. , 2012, Vaccine.
[87] Yu-Chong Tai,et al. Surface micromachined mechanisms and micromotors , 1991 .
[88] J. Bustillo,et al. Surface micromachining for microelectromechanical systems , 1998, Proc. IEEE.
[89] F. Olasagasti,et al. Miniaturized technology for protein and nucleic acid point-of-care testing , 2012, Translational Research.
[90] S. Quake,et al. Monolithic microfabricated valves and pumps by multilayer soft lithography. , 2000, Science.
[91] Mauro Ferrari,et al. Tailoring width of microfabricated nanochannels to solute size can be used to control diffusion kinetics. , 2005, Journal of controlled release : official journal of the Controlled Release Society.
[92] James H. Smith,et al. Micromachined pressure sensors: review and recent developments , 1997, Smart Structures.
[93] M. Allon,et al. Current management of vascular access. , 2007, Clinical journal of the American Society of Nephrology : CJASN.
[94] L. Stevenson,et al. Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial , 2011, The Lancet.
[95] M. Staples,et al. Dosage Form Development, in Vitro Release Kinetics, and in Vitro–in Vivo Correlation for Leuprolide Released from an Implantable Multi-reservoir Array , 2007, Pharmaceutical Research.
[96] Shuvo Roy,et al. Biomolecular Transport Through Hemofiltration Membranes , 2008, Annals of Biomedical Engineering.
[97] H. Polaschegg,et al. Continuous renal replacement therapy for end-stage renal disease. The wearable artificial kidney (WAK). , 2005, Contributions to nephrology.
[98] A. Fleischman,et al. Silicon nanopore membrane technology for an implantable artificial kidney , 2009, TRANSDUCERS 2009 - 2009 International Solid-State Sensors, Actuators and Microsystems Conference.
[99] M. Schmidt. Wafer-to-wafer bonding for microstructure formation , 1998, Proc. IEEE.
[100] Nader Najafi,et al. Initial Animal Studies of a Wireless, Batteryless, MEMS Implant for Cardiovascular Applications , 2004, Biomedical microdevices.
[101] S. N. Kundra,et al. Microelectromechanical systems and neurosurgery: a new era in a new millennium. , 2002, Neurosurgery.
[102] G. Whitesides,et al. Flexible Methods for Microfluidics , 2001 .
[103] M. Lysaght,et al. A wearable hemofilter for continuous ambulatory ultrafiltration. , 2008, Kidney international.
[104] G. Holzapfel,et al. Penetration-Enhanced Ultrasharp Microneedles and Prediction on Skin Interaction for Efficient Transdermal Drug Delivery , 2007, Journal of Microelectromechanical Systems.
[105] N. F. de Rooij,et al. Microfluidics meets MEMS , 2003, Proc. IEEE.
[106] William T. Abraham,et al. Direct Left Atrial Pressure Monitoring in Severe Heart Failure: Long-Term Sensor Performance , 2010, Journal of cardiovascular translational research.
[107] Shuvo Roy,et al. Innovation in the Treatment of Uremia: Proceedings from the Cleveland Clinic Workshop: The Implantable Artificial Kidney , 2009, Seminars in dialysis.
[108] J. Bonventre,et al. Biomarkers of acute kidney injury. , 2008, Annual review of pharmacology and toxicology.
[109] W A Douthwaite,et al. The effect of an artificially elevated intraocular pressure on the central corneal curvature. , 1997, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.
[110] Steffen Leonhardt,et al. Telemetric ICP measurement with the first CE-approved device: data from animal experiments and initial clinical experiences. , 2012, Acta neurochirurgica. Supplement.
[111] S. Gamper,et al. A high-performance silicon micropump for disposable drug delivery systems , 2001, Technical Digest. MEMS 2001. 14th IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.01CH37090).
[112] David W Wright,et al. Guidelines for the management of severe traumatic brain injury. VII. Intracranial pressure monitoring technology. , 2007, Journal of neurotrauma.
[113] R. Howe. Surface micromachining for microsensors and microactuators , 1988 .
[114] P. Renaud,et al. First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens. , 2004, Investigative ophthalmology & visual science.