Investigation of reliability of MEMS gyroscopes under different shock conditions

In this work, the shock survivability of MEMS gyroscopes under different shock conditions are investigated. Both shock experiments and numerical simulations are carried out to study the influences of the shock load level, duration and damping conditions. The simulation results are consistent with the experimental results. The results indicate that the selections of natural frequencies and air-damping conditions are all critical to reach a desired shock resistances of the gyroscopes.

[1]  Jie-ying Tang,et al.  Modeling of MEMS reliability in shock environments , 2004, Proceedings. 7th International Conference on Solid-State and Integrated Circuits Technology, 2004..

[2]  C. Myers,et al.  Strap-down microelectromechanical (MEMS) sensors for high-g munition applications , 2001 .

[3]  S. H. Choa,et al.  Reliability of vacuum packaged MEMS gyroscopes , 2005, Microelectron. Reliab..

[4]  V. T. Srikar,et al.  The reliability of microelectromechanical systems (MEMS) in shock environments , 2002 .

[5]  Jeremy A. Walraven,et al.  MEMS reliability in shock environments , 2000, 2000 IEEE International Reliability Physics Symposium Proceedings. 38th Annual (Cat. No.00CH37059).