Micromechanical mass sensors for biomolecular detection in a physiological environment.

Micromechanical cantilever arrays are used to measure time-resolved adsorption of tiny masses based on protein-ligand interactions. Here, streptavidin-biotin interactions are investigated in a physiological environment. A measurement method is introduced using higher flexural modes of a silicon cantilever in order to enhance the sensitivity of mass detection. Modeling the cantilever vibration in liquid allows the measurement of absolute mass changes. We show time-resolved mass adsorption of final 7+/-0.7 ng biotinylated latex beads. The sensitivity obtained is about 2.5 pg/Hz measuring at a center frequency of 750 kHz.

[1]  H. Rothuizen,et al.  Translating biomolecular recognition into nanomechanics. , 2000, Science.

[2]  M. Schönhoff,et al.  The influence of a viscous fluid on the vibration dynamics of scanning near-field optical microscopy fiber probes and atomic force microscopy cantilevers , 1998 .

[3]  Viola Vogel,et al.  Shear‐dependent ‘stick‐and‐roll’ adhesion of type 1 fimbriated Escherichia coli , 2004, Molecular microbiology.

[4]  Günter Gauglitz,et al.  Surface plasmon resonance sensors: review , 1999 .

[5]  E. Bamberg,et al.  Scan speed limit in atomic force microscopy , 1993 .

[6]  M. Miles,et al.  Chemical sensors and biosensors in liquid environment based on microcantilevers with amplified quality factor. , 2001, Ultramicroscopy.

[7]  R. Corn,et al.  Surface plasmon resonance imaging measurements of DNA and RNA hybridization adsorption onto DNA microarrays. , 2001, Analytical chemistry.

[8]  M. Hegner,et al.  Optical tweezers system measuring the change in light momentum flux , 2002 .

[9]  Thomas Thundat,et al.  RESONANCE RESPONSE OF SCANNING FORCE MICROSCOPY CANTILEVERS , 1994 .

[10]  Wolfgang Knoll,et al.  Surface plasmon resonance spectroscopy and quartz crystal microbalance study of streptavidin film structure effects on biotinylated DNA assembly and target DNA hybridization. , 2005, Langmuir : the ACS journal of surfaces and colloids.

[11]  James K. Gimzewski,et al.  A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout , 2001 .

[12]  H. Lang,et al.  Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever array , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[13]  M. Hegner,et al.  Covalent anchoring of proteins onto gold‐directed NHS‐terminated self‐assembled monolayers in aqueous buffers: SFM images of clathrin cages and triskelia , 1994, FEBS letters.

[14]  James K. Gimzewski,et al.  Observation of a chemical reaction using a micromechanical sensor , 1994 .

[15]  Johannes D. Seelig,et al.  Label-free protein assay based on a nanomechanical cantilever array , 2002 .

[16]  J. Therasse,et al.  Validation of antibody-based recognition by piezoelectric transducers through electroacoustic admittance analysis. , 1998, Biosensors & bioelectronics.

[17]  Martin Hegner,et al.  Rapid Biosensor for Detection of Antibiotic-Selective Growth of Escherichia coli , 2005, Applied and Environmental Microbiology.

[18]  Stefan Weigert,et al.  Frequency shifts of cantilevers vibrating in various media , 1996 .

[19]  Amit K. Gupta,et al.  Single virus particle mass detection using microresonators with nanoscale thickness , 2004 .

[20]  M. Hegner,et al.  Covalent immobilization of native biomolecules onto Au(111) via N-hydroxysuccinimide ester functionalized self-assembled monolayers for scanning probe microscopy. , 1996, Biophysical journal.

[21]  宁北芳,et al.  疟原虫var基因转换速率变化导致抗原变异[英]/Paul H, Robert P, Christodoulou Z, et al//Proc Natl Acad Sci U S A , 2005 .

[22]  F. Elmer,et al.  Eigenfrequencies of a rectangular atomic force microscope cantilever in a medium , 1997 .

[23]  P. Vettiger,et al.  Wafer-scale microdevice transfer/interconnect: its application in an AFM-based data-storage system , 2004, Journal of Microelectromechanical Systems.

[24]  Applied Scanning Probe Methods VII , 2007 .

[25]  J. Gilman,et al.  Nanotechnology , 2001 .

[26]  Thomas Thundat,et al.  Thermal and ambient-induced deflections of scanning force microscope cantilevers , 1994 .