Comparison of gated PET with MRI for evaluation of left ventricular function in patients with coronary artery disease.

UNLABELLED The aim of this study was to compare left ventricular (LV) volumes and regional wall motion determined by PET with those determined by the reference technique, cardiovascular MRI. METHODS LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), and LV ejection fraction (LVEF) were measured and regional wall motion was scored in 38 patients with chronic coronary artery disease by both gated (18)F-FDG PET and MRI. A 9-segment model was used for PET and MRI to assess regional wall motion. RESULTS Good correlations were observed between MRI and gated PET for all parameters (r values ranging from 0.91 to 0.96). With PET, there was a significant but small underestimation of LVEDV and LVEF. Mean +/- SD LVEDV, LVESV, and LVEF for MRI were 131 +/- 57 mL, 91 +/- 12 mL, and 33% +/- 12%, respectively, and those for gated PET were 117 +/- 56 mL, 85 +/- 51 mL, and 30% +/- 11%, respectively. For regional wall motion, an agreement of 85% was found, with a kappa-statistic of 0.79 (95% confidence interval, 0.70-0.89; SE, 0.049). CONCLUSION LV volumes, LVEF, and regional wall motion can be assessed with gated (18)F-FDG PET and correlate well with these parameters assessed by MRI.

[1]  M. Hori,et al.  Myocardial viability assessment with gated SPECT Tc-99m tetrofosmin % wall thickening: Comparison with F-18 FDG-PET , 2002, Annals of nuclear medicine.

[2]  D. Berman,et al.  Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. , 1997, Journal of the American College of Cardiology.

[3]  U. Ruotsalainen,et al.  Euglycemic hyperinsulinemic clamp and oral glucose load in stimulating myocardial glucose utilization during positron emission tomography. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  A. Paans,et al.  Automated ejection fraction determination from gated myocardial FDG-PET data , 1999, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[5]  Diao Mf Predicting improved function after myocardial revascularization. , 1998 .

[6]  Thomas A Trikalinos,et al.  Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: a meta-analysis. , 2002, Journal of the American College of Cardiology.

[7]  F. Maul,et al.  Gated metabolic positron emission tomography (GAPET) of the myocardium: 18F-FDG-PET to optimize recognition of myocardial hibernation. , 1998, Nuclear medicine communications.

[8]  A de Roos,et al.  Left ventricular measurements with cine and spin-echo MR imaging: a study of reproducibility with variance component analysis. , 1993, Radiology.

[9]  T W Redpath,et al.  Regional myocardial wall thickening assessed at rest by ECG gated (18)F-FDG positron emission tomography and by magnetic resonance imaging. , 2000, Heart.

[10]  R. O'rourke,et al.  Comparative Accuracy of Apical Biplane Cross‐sectional Echocardiography and Gated Equilibrium Radionuclide Angiography for Estimating Left Ventricular Size and Performance , 1981, Circulation.

[11]  L Goldman,et al.  Multiple gated cardiac blood pool imaging for left ventricular ejection fraction: validation of the technique and assessment of variability. , 1979, The American journal of cardiology.

[12]  Roger N. Gunn,et al.  Non-invasive measurement of left ventricular volumes and function by gated positron emission tomography , 1996, European Journal of Nuclear Medicine.

[13]  R. Bares,et al.  ECG-gated 18F-FDG positron emission tomography , 2002, The International Journal of Cardiovascular Imaging.

[14]  D. Berman,et al.  Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  Hubert W. Vliegen,et al.  Magnetic Resonance Imaging in Coronary Artery Disease , 1991, Developments in Cardiovascular Medicine.

[16]  R M Whitlock,et al.  Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. , 1987, Circulation.

[17]  R. DeFronzo,et al.  Glucose clamp technique: a method for quantifying insulin secretion and resistance. , 1979, The American journal of physiology.

[18]  Daniel S. Berman,et al.  An automatic approach to the analysis, quantitation and review of perfusion and function from myocardial perfusion SPECT images , 1997, The International Journal of Cardiac Imaging.

[19]  D. Pennell,et al.  Measurement of ventricular volumes and function: a comparison of gated PET and cardiovascular magnetic resonance. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[20]  J.H.C. Reiber,et al.  Automated detection of left ventricular epi- and endocardial contours in short-axis MR images , 1994, Computers in Cardiology 1994.

[21]  G. Wright,et al.  Quantitative gated SPECT: the effect of reconstruction filter on calculated left ventricular ejection fractions and volumes. , 2002, Physics in medicine and biology.

[22]  J. Fleiss Statistical methods for rates and proportions , 1974 .

[23]  W. Grove Statistical Methods for Rates and Proportions, 2nd ed , 1981 .

[24]  M. Verani,et al.  Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: A comparison with cine magnetic resonance imaging , 1999, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[25]  K. Ishii,et al.  Global and regional functional measurements with gated FDG PET in comparison with left ventriculography , 2001, European Journal of Nuclear Medicine.

[26]  Y. Yonekura,et al.  Prediction of reversible ischemia after revascularization. Perfusion and metabolic studies with positron emission tomography. , 1995, Circulation.

[27]  A. Buecker,et al.  Validation of an evaluation routine for left ventricular volumes, ejection fraction and wall motion from gated cardiac FDG PET: a comparison with cardiac magnetic resonance imaging , 2003, European Journal of Nuclear Medicine and Molecular Imaging.