Semi-Active Vibration Suppression of Beam Structures Based on Energy-Recycling Method

An innovative method of semi-active vibration suppression based on an energy-recycling approach using piezoelectric transducers is described. Piezoelectric transducers attached to or embedded in structures can convert the mechanical energy of the structure into electrical energy or, conversely, electrical energy into mechanical energy. Conventional methods have focused on how to effectively dissipate the transferred electrical energy. With our new energy-recycling method, the electrical energy is stored in the transducer functioning as a capacitor and is reused to suppress vibration of the structure, instead of simply being dissipated. This paper presents an advanced energy-recycling method to suppress multiple-mode vibration of beam structures with multiple transducers. Several control strategies based on active control theories are derived from formulae on the dynamics of a beam structure with piezoelectric transducers and electricity. We demonstrate the ability to suppress not only transient vibrations but also vibrations excited by sinusoidal and random forces.

[1]  Yohji Okada,et al.  Variable Resistance Type Energy Regenerative Damper Using Pulse Width Modulated Step-up Chopper , 2002 .

[2]  Daniel Guyomar,et al.  Semi-passive damping using continuous switching of a piezoelectric device , 1999, Smart Structures.

[3]  Heath Hofmann,et al.  Adaptive piezoelectric energy harvesting circuit for wireless remote power supply , 2002 .

[4]  William W. Clark,et al.  Comparison of low-frequency piezoceramic shunt techniques for structural damping , 2001, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[5]  Nesbitt W. Hagood,et al.  Damping of structural vibrations with piezoelectric materials and passive electrical networks , 1991 .

[6]  Shu-yau Wu,et al.  Piezoelectric shunts with a parallel R-L circuit for structural damping and vibration control , 1996, Smart Structures.

[7]  Donald Margolis,et al.  Assessing the Potential for Energy Regeneration in Dynamic Subsystems , 1997 .

[8]  Claude Richard,et al.  Enhanced semi-passive damping using continuous switching of a piezoelectric device on an inductor , 2000, Smart Structures.

[9]  W. Clark Vibration Control with State-Switched Piezoelectric Materials , 2000 .

[10]  Kenji Minesugi,et al.  Semiactive Vibration Suppression with Electrorheological-Fluid Dampers , 1997 .

[11]  D. L. Margolis,et al.  Regenerative Systems for Vibration Control , 1997 .

[12]  George A. Lesieutre,et al.  Vibration damping and control using shunted piezoelectric materials , 1998 .

[13]  Kenji Minesugi,et al.  Energy-Recycling Semi-Active Method for Vibration Suppression with Piezoelectric Transducers , 2003 .

[14]  Kanjuro Makihara,et al.  Energy Recycle Semi-Active Vibration Suppression by Voice Coil Transducers , 2002 .