Insights into the Problem of Alarm Fatigue with Physiologic Monitor Devices: A Comprehensive Observational Study of Consecutive Intensive Care Unit Patients

Purpose Physiologic monitors are plagued with alarms that create a cacophony of sounds and visual alerts causing “alarm fatigue” which creates an unsafe patient environment because a life-threatening event may be missed in this milieu of sensory overload. Using a state-of-the-art technology acquisition infrastructure, all monitor data including 7 ECG leads, all pressure, SpO2, and respiration waveforms as well as user settings and alarms were stored on 461 adults treated in intensive care units. Using a well-defined alarm annotation protocol, nurse scientists with 95% inter-rater reliability annotated 12,671 arrhythmia alarms. Results A total of 2,558,760 unique alarms occurred in the 31-day study period: arrhythmia, 1,154,201; parameter, 612,927; technical, 791,632. There were 381,560 audible alarms for an audible alarm burden of 187/bed/day. 88.8% of the 12,671 annotated arrhythmia alarms were false positives. Conditions causing excessive alarms included inappropriate alarm settings, persistent atrial fibrillation, and non-actionable events such as PVC's and brief spikes in ST segments. Low amplitude QRS complexes in some, but not all available ECG leads caused undercounting and false arrhythmia alarms. Wide QRS complexes due to bundle branch block or ventricular pacemaker rhythm caused false alarms. 93% of the 168 true ventricular tachycardia alarms were not sustained long enough to warrant treatment. Discussion The excessive number of physiologic monitor alarms is a complex interplay of inappropriate user settings, patient conditions, and algorithm deficiencies. Device solutions should focus on use of all available ECG leads to identify non-artifact leads and leads with adequate QRS amplitude. Devices should provide prompts to aide in more appropriate tailoring of alarm settings to individual patients. Atrial fibrillation alarms should be limited to new onset and termination of the arrhythmia and delays for ST-segment and other parameter alarms should be configurable. Because computer devices are more reliable than humans, an opportunity exists to improve physiologic monitoring and reduce alarm fatigue.

[1]  C. Goodman Association for the Advancement of Medical Instrumentation , 1988 .

[2]  W. Rogers,et al.  Preliminary report: effect of encainide and flecainide on mortality in a randomized trial of arrhythmia suppression after myocardial infarction. , 1989, The New England journal of medicine.

[3]  M. Weir,et al.  The Cardiac Arrhythmia Suppression Trial Investigators: Preliminary Report: Effect of Encainide and Flecainide on Mortality in a Randomized Trial of Arrhythmia Suppression After Myocardial Infarction. , 1990 .

[4]  B. Drew,et al.  Bedside diagnosis of myocardial ischemia with ST-segment monitoring technology: measurement issues for real-time clinical decision making and trial designs. , 1998, Journal of electrocardiology.

[5]  J. Alpert,et al.  ACC/AHA Guidelines for Ambulatory Electrocardiography. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Revise the Guidelines for Ambulatory Electrocardiography). Developed in collaboration with the North American Society for P , 1999, Journal of the American College of Cardiology.

[6]  Olle Pahlm,et al.  Twelve-lead electrocardiogram: the advantages of an orderly frontal lead display including lead -aVR. , 2004, Journal of electrocardiology.

[7]  Dan M. Roden,et al.  ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: A report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines , 2006 .

[8]  Mohammed Saeed,et al.  Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform , 2008, J. Biomed. Informatics.

[9]  Matthias Görges,et al.  Improving Alarm Performance in the Medical Intensive Care Unit Using Delays and Clinical Context , 2009, Anesthesia and analgesia.

[10]  Benjamin W Berg,et al.  Alarm limit settings for early warning systems to identify at-risk patients. , 2009, Journal of advanced nursing.

[11]  U. Gather,et al.  Intensive care unit alarms—How many do we need?* , 2010, Critical care medicine.

[12]  Mitochondrial Localization Unveils a Novel Role for Grk2 in the Regulation of Oxidative Metabolism , 2010 .

[13]  Michael J Ackerman,et al.  Prevention of torsade de pointes in hospital settings: a scientific statement from the American Heart Association and the American College of Cardiology Foundation. , 2010, Circulation.

[14]  G. Clifford,et al.  User guide and documentation for the MIMIC II database (version 2, release 1) , 2010 .

[15]  James Welch,et al.  An evidence-based approach to reduce nuisance alarms and alarm fatigue. , 2011, Biomedical instrumentation & technology.

[16]  Li Cui-lan Prevention of Torsade de Pointes in Hospital Settings , 2011 .

[17]  Maarten L. Simoons,et al.  The third universal definition of myocardial infarction , 2013 .

[18]  James P. Keller,et al.  Clinical alarm hazards: a "top ten" health technology safety concern. , 2012, Journal of electrocardiology.

[19]  Fred S Apple,et al.  Third universal definition of myocardial infarction , 2012 .

[20]  Maria M Cvach,et al.  Daily Electrode Change and Effect on Cardiac Monitor Alarms: An Evidence-Based Practice Approach , 2013, Journal of nursing care quality.

[21]  The Joint Commission announces 2014 National Patient Safety Goal. , 2013, Joint Commission perspectives. Joint Commission on Accreditation of Healthcare Organizations.

[22]  Eric T. Carlson,et al.  Development of three methods for extracting respiration from the surface ECG: a review. , 2014, Journal of electrocardiology.

[23]  Deborah Whalen,et al.  Novel Approach to Cardiac Alarm Management on Telemetry Units , 2014, The Journal of cardiovascular nursing.