Frequency-comb-referenced mid-IR sources for next-generation environmental sensors

We report on recent development of IR spectrometers based on non-linear optical generation and quantum-cascade lasers. Frequency stabilization and referencing to optical frequency-comb synthesizers is described. Their characteristics for spectroscopic as well as metrological applications are pointed out. The potential of the combination of mid-IR sources with enhancement cavities for high-resolution and sensitive measurements of gas spectra is illustrated. Finally, we describe wave-front engineering of long wavelength beams for spatial control and imaging applications.

[1]  R W Eason,et al.  Tunable two-dimensional hexagonal phase array in domain-engineered Z-cut lithium niobate crystal. , 2006, Optics letters.

[2]  Jun Ye,et al.  Ultrasensitive detections in atomic and molecular physics: demonstration in molecular overtone spectroscopy , 1998 .

[3]  Rui Q. Yang,et al.  Formaldehyde sensor using interband cascade laser based quartz-enhanced photoacoustic spectroscopy , 2004 .

[4]  D. Romanini,et al.  CW cavity ring down spectroscopy , 1997 .

[5]  A Peters,et al.  Combination of a continuous-wave optical parametric oscillator and a femtosecond frequency comb for optical frequency metrology. , 2005, Optics letters.

[6]  Guilherme de Andrade Garcia,et al.  Stable isotopic analysis of atmospheric methane by infrared spectroscopy by use of diode laser difference-frequency generation. , 2006, Applied optics.

[7]  J G Anderson,et al.  Ultrasensitive absorption spectroscopy with a high-finesse optical cavity and off-axis alignment. , 2001, Applied optics.

[8]  J. B. Paul,et al.  Sensitive absorption measurements in the near-infrared region using off-axis integrated-cavity-output spectroscopy , 2002 .

[9]  Tso Yee Fan,et al.  Beam combining of ytterbium fiber amplifiers (Invited) , 2007 .

[10]  P. De Natale,et al.  Sensitive detection of methane and nitrous oxide isotopomers using a continuous wave quantum cascade laser , 2002 .

[11]  R. Zare,et al.  Cavity ringdown spectroscopy using mid-infrared quantum-cascade lasers. , 2000, Optics letters.

[12]  P. Maddaloni,et al.  Mid-infrared fibre-based optical comb , 2006 .

[13]  Masaki Asobe,et al.  High-power, tunable difference frequency generation source for absorption spectroscopy based on a ridge waveguide periodically poled lithium niobate crystal. , 2007, Optics express.

[14]  Dirk Richter,et al.  First demonstration of a high performance difference frequency spectrometer on airborne platforms. , 2007, Optics express.

[15]  L. Hollberg,et al.  420-MHz Cr:forsterite femtosecond ring laser and continuum generation in the 1-2-μm range , 2003 .

[16]  Daniel Halmer,et al.  Parts per trillion sensitivity for ethane in air with an optical parametric oscillator cavity leak-out spectrometer. , 2004, Optics letters.

[17]  K. Vodopyanov,et al.  Solid-state mid-infrared laser sources , 2003 .

[18]  Rajarshi Roy,et al.  Extracavity laser band-shape and bandwidth modification , 1982 .

[19]  S. Borri,et al.  Power-boosted difference-frequency source for high-resolution infrared spectroscopy , 2003 .

[20]  Simone Borri,et al.  Low-power Lamb-dip spectroscopy of very weak CO(2) transitions near 4.25 mum. , 2002, Optics letters.

[21]  S. Borri,et al.  Saturated-absorption cavity ring-down spectroscopy. , 2009, Physical review letters.

[22]  L. Goldberg,et al.  Second harmonic generation in field poled, quasi-phase-matched, bulk LiNbO/sub 3/ , 1994, IEEE Photonics Technology Letters.

[23]  P. Natale,et al.  Frequency-comb-based absolute frequency measurements in the mid-infrared with a difference-frequency spectrometer. , 2005, Optics letters.

[24]  Frank K. Tittel,et al.  Mid-Infrared Laser Applications in Spectroscopy , 2003 .

[25]  P. De Natale,et al.  A 3.5-mW continuous-wave difference-frequency source around 3 μm for sub-Doppler molecular spectroscopy , 2005, EQEC '05. European Quantum Electronics Conference, 2005..

[26]  P. Hering,et al.  Widely tunable diffraction limited 1000 mW external cavity diode laser in Littman/Metcalf configuration for cavity ring-down spectroscopy , 2006 .

[27]  Katsuaki Magari,et al.  CH4 monitoring in ambient air by communication band laser diode based difference frequency generation in a quasi-phase-matched LiNbO3 waveguide , 2006 .

[28]  Da Chen,et al.  Continuous-wave tunable midwave infrared generation near 4.5 μm with an intracavity optical parametric oscillator and difference frequency generation , 2003 .

[29]  Majid Ebrahim-Zadeh,et al.  Mid-Infrared Ultrafast and Continuous- Wave Optical Parametric Oscillators , 2003 .

[30]  F. Capasso,et al.  Cavity ringdown spectroscopic detection of nitric oxide with a continuous-wave quantum-cascade laser. , 2001, Applied optics.

[31]  Jun Ye,et al.  Precise measurements of optical cavity dispersion and mirror coating properties via femtosecond combs. , 2005, Optics express.

[32]  Frank K. Tittel,et al.  Widely tunable mode-hop free external cavity quantum cascade laser for high resolution spectroscopic applications , 2005 .

[33]  Melania Paturzo,et al.  Mid-infrared tunable two-dimensional Talbot array illuminator , 2009 .

[34]  S. Borri,et al.  Doppler-free polarization spectroscopy with a quantum cascade laser at 4.3 microm. , 2009, Optics express.

[35]  F. Tittel,et al.  Measurements of benzene concentration by difference-frequency laser absorption spectroscopy. , 2000, Applied optics.

[36]  G. Giusfredi,et al.  Ultra-stable, widely tunable and absolutely linked mid-IR coherent source. , 2009, Optics express.

[37]  P. De Natale,et al.  Two-tone frequency modulation spectroscopy for ambient-air trace gas detection using a portable difference-frequency source around 3 μm , 2006 .

[38]  T. L. Myers,et al.  Stabilization, injection and control of quantum cascade lasers, and their application to chemical sensing in the infrared. , 2004, Spectrochimica Acta Part A - Molecular and Biomolecular Spectroscopy.

[39]  E. J. Moyer,et al.  Design considerations in high-sensitivity off-axis integrated cavity output spectroscopy , 2008 .

[40]  S. Corzine,et al.  Widely tunable mode-hop free external cavity quantum cascade lasers for high resolution spectroscopy and chemical sensing , 2008 .

[41]  D. Richter,et al.  13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 μm , 2002, Applied physics. B, Lasers and optics.

[42]  K. Fujita,et al.  Theory of the Intrinsic Linewidth of Quantum-Cascade Lasers: Hidden Reason for the Narrow Linewidth and Line-Broadening by Thermal Photons , 2008, IEEE Journal of Quantum Electronics.

[43]  M. Sigrist,et al.  High-temperature multipass cell for infrared spectroscopy of heated gases and vapors , 2006, 2006 Conference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference.

[44]  Scott A. Diddams,et al.  Molecular fingerprinting with the resolved modes of a femtosecond laser frequency comb , 2007, Nature.

[45]  Frank K. Tittel,et al.  Field measurements of volcanic gases using tunable diode laser based mid-infrared and Fourier transform infrared spectrometers , 2002 .

[46]  S. Borri,et al.  Lamb-dip-locked quantum cascade laser for comb-referenced IR absolute frequency measurements. , 2008, Optics express.

[47]  Jun Ye,et al.  Cavity-enhanced direct frequency comb spectroscopy , 2008, 0803.4509.

[48]  A. Patrinos,et al.  Energy and Technology Policies for Managing Carbon Risk , 2009, Science.

[49]  P De Natale,et al.  Combining a difference-frequency source with an off-axis high-finesse cavity for trace-gas monitoring around 3 microm. , 2006, Optics express.

[50]  P. Hering,et al.  Isotopic ratio measurement of methane in ambient air using mid-infrared cavity leak-out spectroscopy , 2001 .

[51]  D. Uy,et al.  Sub-Doppler resolution limited Lamb-dip spectroscopy of NO with a quantum cascade distributed feedback laser. , 2000, Optics express.

[52]  D T Reid,et al.  Composite frequency comb spanning 0.4-2.4 microm from a phase-controlled femtosecond Ti:sapphire laser and synchronously pumped optical parametric oscillator. , 2007, Optics letters.

[53]  Grant A. D. Ritchie,et al.  4 Cavity ring-down and cavity enhanced spectroscopy using diode lasers , 2005 .

[54]  S. Borri,et al.  Observing the intrinsic linewidth of a quantum-cascade laser: beyond the Schawlow-Townes limit. , 2009, Physical review letters.

[55]  Jun Ye,et al.  Demonstration of a HeNe/CH4-based optical molecular clock. , 2005, Optics letters.

[56]  Olivier Guyon,et al.  Improving the Sensitivity of Astronomical Curvature Wavefront Sensor Using Dual-Stroke Curvature , 2008 .

[57]  Pasquale Maddaloni,et al.  Off-axis integrated-cavity-output spectroscopy for trace-gas concentration measurements: modeling and performance , 2006 .

[58]  Frank K. Tittel,et al.  Ultrasensitive gas detection by quartz-enhanced photoacoustic spectroscopy in the fundamental molecular absorption bands region , 2005 .

[59]  A. Mosk,et al.  Universal optimal transmission of light through disordered materials. , 2008, Physical review letters.

[60]  Paolo De Natale,et al.  A comb-referenced difference-frequency spectrometer for cavity ring-down spectroscopy in the 4.5 µm region , 2006 .

[61]  S. Borri,et al.  Frequency modulation spectroscopy by means of quantum-cascade lasers , 2006 .

[62]  P. Maddaloni,et al.  Optical comb generators for laser frequency measurement , 2009 .

[63]  J G Anderson,et al.  A new cavity based absorption instrument for detection of water isotopologues in the upper troposphere and lower stratosphere. , 2009, The Review of scientific instruments.

[64]  David I. Rosen,et al.  Integrated cavity output spectroscopy measurements of NO levels in breath with a pulsed room-temperature QCL , 2005 .

[65]  Frank K. Tittel,et al.  Sub-ppbv nitric oxide concentration measurements using cw thermoelectrically cooled quantum cascade laser-based integrated cavity output spectroscopy , 2006 .

[66]  T. Hänsch,et al.  Optical frequency metrology , 2002, Nature.

[67]  Mark F Witinski,et al.  Pump-enhanced difference-frequency generation at 3.3 microm. , 2009, Applied optics.

[68]  A W Lohmann,et al.  Making an array illuminator based on the talbot effect. , 1990, Applied optics.

[69]  Thomas Udem,et al.  Frequency comb Vernier spectroscopy for broadband, high-resolution, high-sensitivity absorption and dispersion spectra. , 2007, Physical review letters.

[70]  A. Cho,et al.  High-resolution (Doppler-limited) spectroscopy using quantum-cascade distributed-feedback lasers. , 1998, Optics letters.

[71]  S. Borri,et al.  Frequency-comb-referenced quantum-cascade laser at 4.4 microm. , 2007, Optics letters.

[72]  Markus W. Sigrist,et al.  Mid-infrared laser spectroscopic determination of isotope ratios of N2O at trace levels using wavelength modulation and balanced path length detection , 2007 .