Computer-assisted C1-C2 Transarticular Screw Fixation "Magerl Technique" for Atlantoaxial Instability

Study Design A retrospective study. Purpose To evaluate the surgical results of computer-assisted C1-C2 transarticular screw fixation for atlantoaxial instability and the usefulness of the navigation system. Overview of Literature We used a computed tomography (CT)-based computer navigation system in planning and screw insertion in Magerl's procedure, which provides the most rigid atlantoaxial fusion, to avoid risk of vertebral artery (VA) tear by avoiding high-riding VA during screw insertion. Methods Twenty patients who underwent atlantoaxial fusion under the CT-based navigation system were studied. The mean observation period was 33.5 months. The evaluated items included the existence of VA stenosis by preoperative magnetic resonance angiography, surgical time, blood loss volume, Japanese Orthopaedic Association (JOA) score and Ranawat's pain criteria before surgery and at final follow-up, postoperative screw position evaluated by CT, and bony fusion. Results The mean operation time was 205 minutes, with the mean blood loss volume of 242 ml. The mean JOA score was 11.6 points before surgery and 13.7 at final follow-up. Occipital and/or cervical pain presented before operation was remitted or resolved in all patients. Evaluation of screw insertion by CT revealed correct penetration to atlantoaxial joints, with a perforation rate of 2.6%. There was no complication, including VA tear, and all patients who were followed-up during one year or more after surgery achieved bony fusion. Some subjects who appeared inappropriate for surgery from CT images were assessed as eligible for surgery based on the evaluation results obtained using the navigation system. Conclusions It was demonstrated that the CT-based navigation system is an effective support device for Magerl's procedure.

[1]  N. Wright,et al.  Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS Section on Disorders of the Spine and Peripheral Nerves , 1998 .

[2]  C. Bolger,et al.  C1–C2 Transarticular Screw Fixation for Atlantoaxial Instability due to Rheumatoid Arthritis: A Seven-Year Analysis of Outcome , 2008, Spine.

[3]  J. Stevens,et al.  Craniovertebral junction anomalies in inherited disorders: Part of the syndrome or caused by the disorder? , 1995, European Journal of Pediatrics.

[4]  P. Mummaneni,et al.  Atlantoaxial fixation: overview of all techniques. , 2005, Neurology India.

[5]  H Labelle,et al.  Computer‐Assisted Pedicle Screw Fixation‐ A Feasibility Study , 1995, Spine.

[6]  H. Kato,et al.  Computer-assisted screw insertion for cervical disorders in rheumatoid arthritis , 2007, European Spine Journal.

[7]  F. Magerl,et al.  Thrombosis of the Vertebral Artery: A Rare Complication Following Traumatic Spondylolisthesis of the Second Cervical Vertebra , 1986, Spine.

[8]  Meic H. Schmidt,et al.  Frameless Stereotactic Image-Guided C1-C2 Transarticular Screw Fixation for Atlantoaxial Instability: Review of 20 Patients , 2005, Journal of spinal disorders & techniques.

[9]  H A Crockard,et al.  Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. , 1997, Journal of neurosurgery.

[10]  F Langlotz,et al.  Image‐Guided Insertion of Transpedicular Screws: A Laboratory Set‐Up , 1995, Spine.

[11]  B. Ni,et al.  Bilateral C1–C2 Transarticular Screw and C1 Laminar Hook Fixation and Bone Graft Fusion for Reducible Atlantoaxial Dislocation: A Seven-Year Analysis of Outcome , 2014, PloS one.

[12]  C. Ranawat,et al.  Cervical spine fusion in rheumatoid arthritis. , 1979, The Journal of bone and joint surgery. American volume.

[13]  Andreas Weidner,et al.  Modification of C1–C2 Transarticular Screw Fixation By Image-Guided Surgery , 2000, Spine.

[14]  K. Takaoka,et al.  Accurate pedicle screw insertion under the control of a computer-assisted image guiding system: Laboratory test and clinical study , 1999, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[15]  G B Jacobs,et al.  Frameless stereotactic guidance for surgery of the upper cervical spine. , 1997, Neurosurgery.

[16]  L. Smith,et al.  Clinical use of a frameless stereotactic arm: results of 325 cases. , 1995, Journal of neurosurgery.

[17]  C Bolger,et al.  Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures. , 2000, Journal of neurosurgery.

[18]  C. Edwards,et al.  Comparative Accuracy of Two Insertion Techniques , 2000 .

[19]  C. Ranawat,et al.  A prospective study of the progression of rheumatoid arthritis of the cervical spine. , 1981, The Journal of bone and joint surgery. American volume.

[20]  N. Wright,et al.  Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons. , 1998, Journal of neurosurgery.

[21]  H. Hashidate,et al.  Stable reconstruction using halo vest for unstable upper cervical spine and occipitocervical instability , 2012, European Spine Journal.

[22]  Y. Kawaguchi,et al.  Computer-assisted Magerl's transarticular screw fixation for atlantoaxial subluxation , 2002, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[23]  Hiromu Ito,et al.  Subaxial subluxation after atlantoaxial transarticular screw fixation in rheumatoid patients , 2009, European Spine Journal.

[24]  Accuracy of Spinal Navigation for Magerl Screws , 2003, Clinical orthopaedics and related research.

[25]  H. Abe,et al.  Atlantoaxial dislocation associated with neurofibromatosis. Report of three cases. , 1983, Journal of neurosurgery.

[26]  Manabu Ito,et al.  A Retrospective Radiographic Analysis of Subaxial Sagittal Alignment After Posterior C1–C2 Fusion , 2004, Spine.

[27]  P. Kehr,et al.  Cervical Spine I , 1987, Springer Vienna.

[28]  J. Heller Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. , 2000, Journal of spinal disorders.

[29]  H. Hashidate,et al.  Perforation Rates of Cervical Pedicle Screw Insertion by Disease and Vertebral Level , 2010, The open orthopaedics journal.

[30]  P. Suchomel,et al.  [Transarticular fixation of C1-C2: a multicenter retrospective study]. , 2004, Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca.

[31]  F. Magerl,et al.  Stable Posterior Fusion of the Atlas and Axis by Transarticular Screw Fixation , 1987 .

[32]  C. Dickman,et al.  The anatomical suitability of the C1-2 complex for transarticular screw fixation. , 1996, Journal of neurosurgery.

[33]  C. Edwards,et al.  Cervical Pedicle Screws: Comparative Accuracy of Two Insertion Techniques , 2000, Spine.

[34]  M. Richter,et al.  Computer-assisted surgery in posterior instrumentation of the cervical spine: an in-vitro feasibility study , 2000, European Spine Journal.

[35]  H. Hashidate,et al.  Accuracy of Multilevel Registration in Image-Guided Pedicle Screw Insertion for Adolescent Idiopathic Scoliosis , 2010, Spine.

[36]  Michael A. Finn,et al.  Atlantoaxial Transarticular Screw Fixation: Update on Technique and Outcomes in 269 Patients , 2010, Neurosurgery.