Body composition by DEXA in older adults: accuracy and influence of scan mode.

Dual energy x-ray absorptiometry (DEXA) measures bone mineral content (BMC), bone mineral density (BMD), fat-free mass (FFM), and provides estimates of percent body fat. Changes in scan mode geometry (pencil beam vs array) may impact these measures and body composition estimates using multi-compartment models. Forty-one adults, ages 59-79 yr, were scanned in each mode and also underwent hydrostatic weighing and measurement of total body water (tritiated water dilution). The effect of scan mode on measurement of DEXA BMC, BMD, FFM, and percent body fat (DEXA %Fat) was examined. The effect of scan mode on percentage body fat determined by a 4-compartment body composition model (4 Comp %Fat) and comparison of DEXA %Fat and 4 Comp %Fat were also examined. BMC and DEXA %Fat were greater (1.3% and 3.9%, respectively, P < 0.01), and BMD and FFM were lower (1.1% and 1.9%, respectively, P < 0.01) with the array scan mode. The 4 Comp %Fat was significantly greater (0.2%) when the array scan mode measurements of total body bone mineral were used; however, these differences were physiologically inconsequential. Comparison between DEXA %Fat and 4 Comp %Fat measures revealed a total error of +/-5.0% in the older adults examined. These results indicate significant scan mode differences in total body BMC, BMD, FFM, and DEXA %Fat measurements and demonstrate the importance of using a single DEXA scan mode for clinical investigation, particularly with longitudinal studies. For all investigations with DEXA, the scan mode should be reported. Furthermore, the error associated with using DEXA alone to estimate percent fat in an older population suggests that this technique is unacceptable in a research setting.

[1]  S. Heymsfield,et al.  Body composition in humans: advances in the development of multicompartment chemical models. , 2009, Nutrition reviews.

[2]  R. Pierson,et al.  Analysis of body-composition techniques and models for detecting change in soft tissue with strength training. , 1996, The American journal of clinical nutrition.

[3]  M. Van Loan,et al.  Evaluation of body composition by dual energy x-ray absorptiometry and two different software packages. , 1995, Medicine and science in sports and exercise.

[4]  P. Eiken,et al.  Switching from DXA pencil-beam to fan-beam. I: Studies in vitro at four centers. , 1994, Bone.

[5]  P. Eiken,et al.  Switching from DXA pencil-beam to fan-beam. II: Studies in vivo. , 1994, Bone.

[6]  S B Heymsfield,et al.  Use of dual-energy x-ray absorptiometry in body-composition studies: not yet a "gold standard". , 1993, The American journal of clinical nutrition.

[7]  G. Blake,et al.  Dual X-ray absorptiometry: a comparison between fan beam and pencil beam scans. , 1993, The British journal of radiology.

[8]  M. Jensen,et al.  How valid are isotopic measurements of fatty acid oxidation? , 1991, The American journal of physiology.

[9]  R. Baumgartner,et al.  Body composition in elderly people: effect of criterion estimates on predictive equations. , 1991, The American journal of clinical nutrition.

[10]  R. Baumgartner,et al.  Body composition of humans: comparison of two improved four-compartment models that differ in expense, technical complexity, and radiation exposure. , 1990, The American journal of clinical nutrition.

[11]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[12]  J H Wilmore,et al.  A simplified method for determination of residual lung volumes. , 1969, Journal of applied physiology.

[13]  F. Katch,et al.  Estimation of body volume by underwater weighing: description of a simple method. , 1967, Journal of applied physiology.

[14]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.