Exact image reconstruction with triple-source saddle-curve cone-beam scanning.

In this paper, we propose an exact shift-invariant filtered backprojection (FBP) algorithm for triple-source saddle-curve cone-beam CT. In this imaging geometry, the x-ray sources are symmetrically positioned along a circle, and the trajectory of each source is a saddle curve. Then, we extend Yang's formula from the single-source case to the triple-source case. The saddle curves can be divided into four parts to yield four datasets. Each of them contains three data segments associated with different saddle curves, respectively. Images can be reconstructed on the planes orthogonal to the z-axis. Each plane intersects the trajectories at six points (or three points at the two ends) which can be used to define the filtering directions. Then, we discuss the properties of these curves and study the case of 2N+1 sources (N>or=2). A necessary condition and a sufficient condition are given to find efficient curves. Finally, we perform numerical simulations to demonstrate the feasibility of our triple-source saddle-curve approach. The results show that the triple-source geometry is advantageous for high temporal resolution imaging, especially important for cardiac imaging and small animal imaging.

[1]  Ping Chin Cheng,et al.  Scanning cone-beam reconstruction algorithms for x-ray microtomography , 1992, Optics & Photonics.

[2]  M. Defrise,et al.  Tiny a priori knowledge solves the interior problem in computed tomography , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[3]  Ge Wang,et al.  Filtered backprojection formula for exact image reconstruction from cone-beam data along a general scanning curve. , 2004, Medical physics.

[4]  H. Kudo,et al.  Application of Pack and Noo's Cone-Beam Inversion Formula to a Wide Class of Trajectories , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[5]  Ge Wang,et al.  Guest Editorial - Multirow Detector and Cone-Beam Spiral/Helical CT , 2000, IEEE Trans. Medical Imaging.

[6]  Willi A Kalender,et al.  Intensity distribution and impact of scatter for dual-source CT , 2007, Physics in medicine and biology.

[7]  Lawrence Weiskrantz,et al.  Discussions and conclusions , 1998 .

[8]  Hengyong Yu,et al.  Data Consistency Based Rigid Motion Artifact Reduction in Fan-Beam CT , 2007, IEEE Transactions on Medical Imaging.

[9]  Alexander Katsevich,et al.  Theoretically Exact Filtered Backprojection-Type Inversion Algorithm for Spiral CT , 2002, SIAM J. Appl. Math..

[10]  Bruno De Man,et al.  An outlook on x-ray CT research and development. , 2008, Medical physics.

[11]  Jun Zhao,et al.  A Filtered Backprojection Algorithm for Triple-Source Helical Cone-Beam CT , 2009, IEEE Transactions on Medical Imaging.

[12]  W. Kalender Thin-section three-dimensional spiral CT: is isotropic imaging possible? , 1995, Radiology.

[13]  L Xing,et al.  Motion correction for improved target localization with on-board cone-beam computed tomography , 2006, Physics in medicine and biology.

[14]  Per-Erik Danielsson,et al.  Helical cone‐beam tomography , 2000 .

[15]  E.A. Hoffman,et al.  High-speed three-dimensional X-ray computed tomography: The dynamic spatial reconstructor , 1983, Proceedings of the IEEE.

[16]  M. Jiang,et al.  An exact reconstruction algorithm for triple-source helical cone-beam CT , 2006 .

[17]  H. Otero,et al.  Initial evaluation of coronary images from 320-detector row computed tomography , 2008, The International Journal of Cardiovascular Imaging.

[18]  A. Katsevich A GENERAL SCHEME FOR CONSTRUCTING INVERSION ALGORITHMS FOR CONE BEAM CT , 2003 .

[19]  V. Rovenski,et al.  Differential Geometry of Curves and Surfaces: A Concise Guide , 2005 .

[20]  K. Stierstorfer,et al.  First performance evaluation of a dual-source CT (DSCT) system , 2006, European Radiology.

[21]  H. Kudo,et al.  Exact cone beam reconstruction for a saddle trajectory. , 2006, Physics in medicine and biology.

[22]  Zhye Yin,et al.  3D analytic cone-beam reconstruction for less than a full scan using a multi-source CT system , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[23]  Yang Lu,et al.  Exact image reconstruction for triple-source cone-beam CT along saddle trajectories , 2008, Optical Engineering + Applications.

[24]  Pierre Grangeat,et al.  Theoretical framework for a dynamic cone-beam reconstruction algorithm based on a dynamic particle model. , 2002, Physics in medicine and biology.

[25]  F. Noo,et al.  Cone-beam reconstruction using 1D filtering along the projection of M-lines , 2005 .

[26]  K. Taguchi,et al.  Algorithm for image reconstruction in multi-slice helical CT. , 1998, Medical physics.

[27]  Hengyong Yu,et al.  A General Local Reconstruction Approach Based on a Truncated Hilbert Transform , 2007, Int. J. Biomed. Imaging.

[28]  T. Flohr,et al.  Chasing the heart: new developments for cardiac CT. , 2007, Journal of thoracic imaging.