Spectral Computed Tomography: Technique and Applications for Head and Neck Cancer.

Spectral computed tomography (CT) or dual-energy CT (DECT) is an advanced form of CT with increasing applications in head and neck radiology. This article provides an overview of the DECT technique and reviews current applications for the evaluation of neck pathology, focusing on oncologic applications. Included are an overview of the basic underlying principles and approaches for DECT scan acquisition and material characterization; a discussion of various DECT reconstructions and a brief overview of practical issues pertaining to DECT implementation, including those related to workflow impact of DECT; and a discussion of various applications of DECT for the evaluation of the neck, especially in oncology.

[1]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[2]  Naveen M. Kulkarni,et al.  Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose , 2013, European Radiology.

[3]  T. Yamanaka,et al.  Evaluation of cartilage invasion by laryngeal and hypopharyngeal squamous cell carcinoma with dual-energy CT. , 2012, Radiology.

[4]  Matthias Hammon,et al.  Dual-Energy Computed Tomography Angiography of the Head and Neck With Single-Source Computed Tomography: A New Technical (Split Filter) Approach for Bone Removal , 2016, Investigative radiology.

[5]  T. Lehnert,et al.  Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer , 2015, European Radiology.

[6]  M G Mack,et al.  Image Quality and Radiation Dose of Dual-Energy CT of the Head and Neck Compared with a Standard 120-kVp Acquisition , 2011, American Journal of Neuroradiology.

[7]  Dan Xu,et al.  Dual energy CT via fast kVp switching spectrum estimation , 2009, Medical Imaging.

[8]  M. Goodsitt,et al.  Dual-Energy CT-Based Differentiation of Benign Posttreatment Changes From Primary or Recurrent Malignancy of the Head and Neck: Comparison of Spectral Hounsfield Units at 40 and 70 keV and Iodine Concentration. , 2016, AJR. American journal of roentgenology.

[9]  M. Wintermark,et al.  Evaluation of monoenergetic imaging to reduce metallic instrumentation artifacts in computed tomography of the cervical spine. , 2015, Journal of neurosurgery. Spine.

[10]  Rajiv Gupta,et al.  Dual-Energy Head CT Enables Accurate Distinction of Intraparenchymal Hemorrhage from Calcification in Emergency Department Patients. , 2016, Radiology.

[11]  Alain Vlassenbroek,et al.  Dual Layer CT , 2011 .

[12]  H. Alkadhi,et al.  Monoenergetic computed tomography reconstructions reduce beam hardening artifacts from dental restorations , 2013, Forensic Science, Medicine, and Pathology.

[13]  V. Yeager,et al.  Evaluation of Laryngeal Cartilages by Computed Tomography , 1979, Journal of computer assisted tomography.

[14]  R. Sader,et al.  Dual-energy CT applications in head and neck imaging. , 2012, AJR. American journal of roentgenology.

[15]  T. Flohr,et al.  Dual Source CT , 2011 .

[16]  C. McCollough,et al.  Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications. , 2015, Radiology.

[17]  Hugh D Curtin,et al.  Low-Energy Virtual Monochromatic Dual-Energy Computed Tomography Images for the Evaluation of Head and Neck Squamous Cell Carcinoma: A Study of Tumor Visibility Compared With Single-Energy Computed Tomography and User Acceptance , 2017, Journal of computer assisted tomography.

[18]  R. Forghani,et al.  Dual-Energy Computed Tomography of the Neck: A Pictorial Review of Normal Anatomy, Variants, and Pathologic Entities Using Different Energy Reconstructions and Material Decomposition Maps. , 2017, Neuroimaging clinics of North America.

[19]  Ralf W. Bauer,et al.  Dual-Energy CT of Head and Neck Cancer: Average Weighting of Low- and High-Voltage Acquisitions to Improve Lesion Delineation and Image Quality—Initial Clinical Experience , 2012, Investigative radiology.

[20]  Bruno De Man,et al.  Dual-Energy Computed Tomography: Physical Principles, Approaches to Scanning, Usage, and Implementation: Part 1. , 2017, Neuroimaging clinics of North America.

[21]  K. Stierstorfer,et al.  First performance evaluation of a dual-source CT (DSCT) system , 2006, European Radiology.

[22]  Christianne Leidecker,et al.  Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images? , 2009, Radiology.

[23]  Applications of Dual-Energy Computed Tomography for the Evaluation of Head and Neck Squamous Cell Carcinoma. , 2017, Neuroimaging clinics of North America.

[24]  H. Onaya,et al.  Primary staging of laryngeal and hypopharyngeal cancer: CT, MR imaging and dual-energy CT. , 2014, European journal of radiology.

[25]  Konstantin Nikolaou,et al.  Dual Energy CT of the Chest: How About the Dose? , 2010, Investigative radiology.

[26]  Qualitative Comparison of Noncontrast Head Dual-Energy Computed Tomography Using Rapid Voltage Switching Technique and Conventional Computed Tomography , 2016, Journal of computer assisted tomography.

[27]  David Allen Langan,et al.  Gemstone Detector: Dual Energy Imaging via Fast kVp Switching , 2011 .

[28]  Bruno De Man,et al.  Dual-Energy Computed Tomography: Physical Principles, Approaches to Scanning, Usage, and Implementation: Part 2. , 2017, Neuroimaging clinics of North America.

[29]  Konstantin Nikolaou,et al.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation , 2011, European Radiology.

[30]  P. Dulguerov,et al.  Neoplastic invasion of laryngeal cartilage: reassessment of criteria for diagnosis at MR imaging. , 2008, Radiology.

[31]  Yoshiyuki Noto,et al.  Reduction of dark-band-like metal artifacts caused by dental implant bodies using hypothetical monoenergetic imaging after dual-energy computed tomography. , 2013, Oral surgery, oral medicine, oral pathology and oral radiology.

[32]  R Gupta,et al.  Optimal Virtual Monochromatic Images for Evaluation of Normal Tissues and Head and Neck Cancer Using Dual-Energy CT , 2015, American Journal of Neuroradiology.

[33]  François DeBlois,et al.  Dual-Energy CT: Balance Between Iodine Attenuation and Artifact Reduction for the Evaluation of Head and Neck Cancer , 2017, Journal of computer assisted tomography.

[34]  Rajiv Gupta,et al.  Multiparametric Evaluation of Head and Neck Squamous Cell Carcinoma Using a Single-Source Dual-Energy CT with Fast kVp Switching: State of the Art , 2015, Cancers.

[35]  Minerva Becker,et al.  Imaging of the larynx and hypopharynx. , 2008, European journal of radiology.

[36]  W. Guo,et al.  Differentiation of malignant cervical lymphadenopathy by dual-energy CT: a preliminary analysis , 2016, Scientific Reports.

[37]  W D McDavid,et al.  Extraction of information from CT scans at different energies. , 1979, Medical physics.

[38]  Li Xiao,et al.  Dual-Energy Computed Tomography Imaging of Thyroid Nodule Specimens: Comparison With Pathologic Findings , 2012, Investigative radiology.

[39]  R. Alvarez,et al.  Comparison of dual energy detector system performance. , 2004, Medical physics.

[40]  Hongxia Cheng,et al.  A retrospective study of dual-energy CT for clinical detecting of metastatic cervical lymph nodes in laryngeal and hypopharyngeal squamous cell carcinoma , 2015, Acta oto-laryngologica.

[41]  T. Johnson,et al.  Dual-energy CT: general principles. , 2012, AJR. American journal of roentgenology.

[42]  T J Vogl,et al.  Non-linear image blending improves visualization of head and neck primary squamous cell carcinoma compared to linear blending in dual-energy CT. , 2015, Clinical radiology.

[43]  Bernhard Krauss,et al.  Initial Results of a Single-Source Dual-Energy Computed Tomography Technique Using a Split-Filter: Assessment of Image Quality, Radiation Dose, and Accuracy of Dual-Energy Applications in an In Vitro and In Vivo Study , 2016, Investigative radiology.

[44]  Robert Hermans,et al.  Staging of laryngeal and hypopharyngeal cancer: value of imaging studies , 2006, European Radiology.

[45]  K. Choi,et al.  Cartilage Involvement in Laryngeal Carcinoma: Correlation of CT and Pathologic Macrosection Studies , 1984, Journal of computer assisted tomography.

[46]  M. Reiser,et al.  Material differentiation by dual energy CT: initial experience , 2007, European Radiology.

[47]  R. Gupta,et al.  Different Spectral Hounsfield Unit Curve and High-Energy Virtual Monochromatic Image Characteristics of Squamous Cell Carcinoma Compared with Nonossified Thyroid Cartilage , 2015, American Journal of Neuroradiology.

[48]  Ashok Srinivasan,et al.  Utility of dual-energy CT virtual keV monochromatic series for the assessment of spinal transpedicular hardware-bone interface. , 2013, AJR. American journal of roentgenology.

[49]  L L Berland,et al.  Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: optimization of energy level viewing significantly increases lesion contrast. , 2013, Clinical radiology.

[50]  R. Forghani Advanced dual-energy CT for head and neck cancer imaging , 2015, Expert review of anticancer therapy.

[51]  R. Forghani,et al.  Computed Tomography Appearance of Normal Nonossified Thyroid Cartilage: Implication for Tumor Invasion Diagnosis , 2015, Journal of computer assisted tomography.

[52]  Sachio Kuribayashi,et al.  Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT. , 2011, Radiology.

[53]  M. Becker,et al.  Neoplastic invasion of laryngeal cartilage: radiologic diagnosis and therapeutic implications. , 2000, European Journal of Radiology.

[54]  Kuni Ohtomo,et al.  Preliminary report on virtual monochromatic spectral imaging with fast kVp switching dual energy head CT: comparable image quality to that of 120-kVp CT without increasing the radiation dose , 2013, Japanese Journal of Radiology.

[55]  Julian L Wichmann,et al.  Virtual Monoenergetic Dual-Energy Computed Tomography: Optimization of Kiloelectron Volt Settings in Head and Neck Cancer , 2014, Investigative radiology.

[56]  Thomas J. Vogl,et al.  Comparison of dual-energy CT-derived iodine content and iodine overlay of normal, inflammatory and metastatic squamous cell carcinoma cervical lymph nodes , 2013, European Radiology.