Effective calculation of power system low-voltage solutions

This paper develops a method for reliably determining the set of low-voltage solutions which are closest to the operable power flow solution. These solutions are often used in conjunction with techniques such as energy methods and the voltage instability proximity index for assessing power system voltage stability. This paper presents an algorithm which provides good initial guesses for these solutions. The results are demonstrated on a small power system and on larger power systems with up to 2000 buses.

[1]  L. Ni,et al.  Parallel processing for the load flow of power systems: the approach and applications , 1989, Proceedings of the 28th IEEE Conference on Decision and Control,.

[2]  I. Dobson Observations on the geometry of saddle node bifurcation and voltage collapse in electrical power systems , 1992 .

[3]  Xiaodong Yin,et al.  Investigations On Solving the Load Flow Problem By Genetic Algorithms , 1991 .

[4]  Thomas J. Overbye,et al.  Voltage security enhancement using energy based sensitivities , 1991 .

[5]  W. F. Tinney,et al.  Sparse Vector Methods , 1985, IEEE Transactions on Power Apparatus and Systems.

[6]  Thomas J. Overbye,et al.  Effects of load modelling on analysis of power system voltage stability , 1994 .

[7]  I. Dobson,et al.  New methods for computing a closest saddle node bifurcation and worst case load power margin for voltage collapse , 1993 .

[8]  M. Pai,et al.  Power system steady-state stability and the load-flow Jacobian , 1990 .

[9]  Claudio A. Canizares,et al.  Point of collapse and continuation methods for large AC/DC systems , 1993 .

[10]  C. W. Taylor,et al.  Standard load models for power flow and dynamic performance simulation , 1995 .

[11]  N. Yorino,et al.  A method to approximate a closest loadability limit using multiple load flow solutions , 1997 .

[12]  Robert J. Thomas,et al.  A posturing strategy against voltage instabilities in electric power systems , 1988 .

[13]  Thomas J. Overbye,et al.  Improved techniques for power system voltage stability assessment using energy methods , 1991 .

[14]  James S. Thorp,et al.  Solving for all the solutions of power systems equations , 1992, [Proceedings] 1992 IEEE International Symposium on Circuits and Systems.

[15]  Y. Tamura,et al.  A Load Flow Calculation Method for Ill-Conditioned Power Systems , 1981, IEEE Transactions on Power Apparatus and Systems.

[16]  Ian Dobson,et al.  Towards a theory of voltage collapse in electric power systems , 1989 .

[17]  Wilsun Xu,et al.  Voltage stability analysis using generic dynamic load models , 1994 .

[18]  M. Suzuki,et al.  Newly developed voltage security monitoring system , 1992 .

[19]  Thomas J. Overbye Use of energy methods for on-line assessment of power system voltage security , 1993 .

[20]  Y. Tayama,et al.  Voltage instability proximity index (VIPI) based on multiple load flow solutions in ill-conditioned power systems , 1988, Proceedings of the 27th IEEE Conference on Decision and Control.

[21]  Thomas J. Overbye,et al.  Computation of a practical method to restore power flow solvability , 1995 .

[22]  Y. Tamura,et al.  Relationship Between Voltage Instability and Multiple Load FLow Solutions in Electric Power Systems , 1983, IEEE Transactions on Power Apparatus and Systems.

[23]  K. Iba,et al.  A method for finding a pair of multiple load flow solutions in bulk power systems , 1989, Conference Papers Power Industry Computer Application Conference.

[24]  Thomas J. Overbye,et al.  Q-V curve interpretations of energy measures for voltage security , 1994 .

[25]  Thomas J. Overbye,et al.  An energy based security measure for assessing vulnerability to voltage collapse , 1990 .