Total analysis of cooling effects of cross-ventilation affected by microclimate around a building

Abstract This study aims to develop a simulation system for evaluating the passive cooling effects, such as cross-ventilation, solar shading by trees, etc. Since the passive cooling effects are strongly affected by the spatial distributions of airflow, air temperature and radiative heat transports around a building, the microclimate around a building should be accurately predicted for this type of simulations. In this study, convective and radiative heat transports around buildings are analyzed by CFD (computational fluid dynamics) and radiation computations. Furthermore, the heat load calculation with the program “TRNSYS” was carried out, using the values of the cross-ventilation rates predicted by CFD computation and incoming solar radiation onto the building walls under the shade of trees obtained by the radiation computation as boundary conditions. Indoor velocity and indoor air temperature obtained by the simulation system developed here showed generally good agreement with measured data.

[1]  Yoshihiko Hayashi,et al.  Examining the κ-ϵ model by means of a wind tunnel test and large-eddy simulation of the turbulence structure around a cube , 1990 .

[2]  Qingyan Chen,et al.  Natural Ventilation Design for Houses in Thailand , 2001 .

[3]  Yoshihide Tominaga,et al.  Comparison of various k-ε models and DSM applied to flow around a high-rise building - report on AIJ cooperative project for CFD prediction of wind environment - , 2002 .

[4]  Takashi Kurabuchi,et al.  Study on airflow characteristics inside and outside a cross-ventilation model, and ventilation flow rates using wind tunnel experiments , 2001 .

[5]  B. Launder,et al.  THE NUMERICAL COMPUTATION OF TURBULENT FLOW , 1974 .

[6]  Qingyuan Zhang,et al.  Residential energy consumption in China and its comparison with Japan, Canada, and USA , 2004 .

[7]  Mario Grosso,et al.  Fundamentals of the Multizone Air Flow Model - COMIS , 1990 .

[8]  Tetsuo Hayashi,et al.  Investigation and numerical simulation of the wind effects on thermal comfort in a house , 1996 .

[9]  Qingyan Chen,et al.  Effect of fluctuating wind direction on cross natural ventilation in buildings from large eddy simulation , 2002 .

[10]  Shinsuke Kato,et al.  Radiational panel cooling system with continuous natural cross ventilation for hot and humid regions , 2004 .

[11]  Hiroshi Yoshino,et al.  Indoor thermal environment of urban residential buildings in China: winter investigation in five major cities , 2004 .

[12]  周三 村上,et al.  樹木モデルを組み込んだ対流・放射・湿気輸送連成解析による樹木の屋外温熱環境緩和効果の検討 , 2000 .

[13]  Gail Brager,et al.  Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55 , 2002 .

[14]  P. Durbin On the k-3 stagnation point anomaly , 1996 .

[15]  Yuguo Li,et al.  Prediction of natural ventilation in buildings with large openings , 2000 .

[16]  S. Kato,et al.  Study on outdoor thermal environment of apartment block in Shenzhen, China with coupled simulation of convection, radiation and conduction , 2004 .

[17]  日本建築学会,et al.  Expanded AMeDAS Weather Data , 2000 .

[18]  M. Liddament,et al.  A guide to energy efficient ventilation , 1996 .

[19]  B. Launder,et al.  The numerical computation of turbulent flows , 1990 .

[20]  Murray Milne,et al.  Effects of window size and thermal mass on building comfort using an intelligent ventilation controller , 2004 .

[21]  Guglielmina Mutani,et al.  Experimental and theoretical analysis of natural ventilation by windows opening , 2002 .