Image-Free Technique for Flow Mediated Dilation Using ARTSENS® Pen

Flow mediated dilation (FMD) is a clinically accepted non-invasive tool for assessing endothelial dysfunction. FMD is conventionally performed with B-mode ultrasound systems that involve recording of the image sequences as DICOM files or video-graphic files and processing them offline. Sometimes the examinations may have to be rejected due to poor or unstable image sequences resulting non-reliable diameter estimates. We had earlier developed and extensively validated an image-free ultrasound technology, ARTSENS®, for the measurement of carotid artery wall dynamics and arterial stiffness metrics. In this work, we evaluate the feasibility of using the technology for continuous real-time diameter measurement of the brachial artery and thereby FMD. To investigate the performance of the ARTSENS® device an in-vivo study was conducted on 5 subjects as pilot. As a reference the measurements were also performed by a B-mode imaging system with a help of a commercially available clinically validated offline FMD analysis tool. The brachial artery diameter and FMD measurements performed by the ARTSENS® device were consistent with the earlier reported literature. The beat-to-beat repeatability of the baseline diameter measurements was acceptable with a CoV < 4% for all the subjects. The diameter measurements performed by the two devices exhibited a significant correlation (r-square = 0.81, p < 0.05). The RMSE for the diameter and FMD% measurements was 0.32 mm and 0.63% respectively, illustrating the measurement accuracy. The study demonstrated that the ARTSENS® can be reliably employed for performing FMD measurements and assessing endothelial dysfunction. This would help realize a field deployable solution for real-time automated FMD measurement and consequently for the acceleration of large population studies in this research area.

[1]  Mohanasankar Sivaprakasam,et al.  ARTSENS® Pen: A portable, image-free device for automated evaluation of vascular stiffness , 2016, 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA).

[2]  E. Benjamin,et al.  Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery: a report of the International Brachial Artery Reactivity Task Force. , 2002, Journal of the American College of Cardiology.

[3]  Mohanasankar Sivaprakasam,et al.  Automated system for imageless evaluation of arterial compliance , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  S. Laurent,et al.  Flow-mediated vasodilation in end-stage renal disease. , 2011, Clinical journal of the American Society of Nephrology : CJASN.

[5]  S. Verma,et al.  Fundamentals of endothelial function for the clinical cardiologist. , 2002, Circulation.

[6]  Massimo Salvetti,et al.  Evaluation of Endothelial Function by Flow Mediated Dilation: Methodological Issues and Clinical Importance , 2015, High Blood Pressure & Cardiovascular Prevention.

[7]  Amir Lerman,et al.  Coronary Endothelial Dysfunction Is Associated With an Increased Risk of Cerebrovascular Events , 2003, Circulation.

[8]  Mohanasankar Sivaprakasam,et al.  Technical Validation of ARTSENS–An Image Free Device for Evaluation of Vascular Stiffness , 2015, IEEE Journal of Translational Engineering in Health and Medicine.

[9]  T. Gasser,et al.  Variability and reproducibility of flow-mediated dilatation in a multicentre clinical trial. , 2013, European heart journal.

[10]  F. Ohsuzu,et al.  Flow-mediated dilation in brachial artery in the second half of pregnancy and prediction of pre-eclampsia , 2003, Journal of Human Hypertension.

[11]  Mohanasankar Sivaprakasam,et al.  ARTSENS - An image-free system for noninvasive evaluation of arterial compliance , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[12]  J. Joseph,et al.  Automatic Measurement of End-Diastolic Arterial Lumen Diameter in ARTSENS , 2015 .

[13]  T. Rabelink,et al.  Endothelial function and dysfunction: testing and clinical relevance. , 2007, Circulation.

[14]  Marcello Demi,et al.  A System for Real-Time Measurement of the Brachial Artery Diameter in B-Mode Ultrasound Images , 2007, IEEE Transactions on Medical Imaging.