Measurement and Analysis on the Mixing Flows in a Tank with a Bottom Agitator using a Hybrid Volume Measurement Technique

Abstract. Experimental data for the flows in a mixing tank with a bottom agitator are useful for the val-idation of CFD commercial code. A hybrid volume PIV measurement technique was constructed to mea-sure the flows inside of the mixing tank. The measurement system consists of three cameras. An agitatorwas installed at the bottom of the tank and it rotates clockwise and counterclockwise. Using the con-structed measurement system, instantaneous vector fields were obtained. A phase averaging technique wasadopted for the measured instantaneous three-dimensional velocity vector fields. Turbulent properties wereevaluated from the instantaneous vector fields. Key Words:Hybrid 3D Volume PIV(하이브리드 볼륨 PIV), Bottom Agitator(하부교반), Mixing TankFlow(혼합탱크 유동) 1. 연구 배경 교반탱크 내부의 유동은 일반적으로 강한 3차원성을 지닐 뿐만 아니라 경우에 따라서는 (3)기포발생 등으로 기액혼상류가 발생하게 된다. 이와 같은 유동상태에 대한 CFD(Computational Fluid Dynamics)해석 결과에 신뢰성 향상을 위해서는 실험적 검증이 필요하게된다. Hu (1) 는 고체/액체 이상유동의 교반기 내부에 대한 CFD연구를 통하여 교반기 내부의 고체입자의 분포를 예측한 바 있지만 심층적 실험결과와의 비교가 필요하였다. Ochieng et al.