A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA).

Endovascular treatment of abdominal aortic aneurysms (AAA) is a promising new alternative to the traditional surgical repair. However, the endovascular approach suffers problems such as stent graft migration, endoleaks and stent mechanism breakage. Fatigue failure is believed to be the major cause of stent graft migration and device breakage. Knowledge of the in vivo forces acting on such devices is a basic requirement for the design of a successful endovascular device. Using a Fourier series trigonometric fit of a typical pressure and flow relationship, a mathematical model, using the control volume method, was developed to predict the pulsatile drag forces acting on various bifurcated stent graft geometries. It was found that for an iliac angle of 30 degrees, a proximal diameter of 24 mm and an iliac diameter of 12 mm, the drag force varied, over the cardiac cycle, between 3.9 and 5.5 N in the axial direction. It was noted that for a specific iliac angle the drag force variation with proximal diameter approximates a quadratic fit, with an increase in proximal diameter producing an increase in drag force. The more compliant the aorta the higher the drag force. Previously published results demonstrated the axial loads (axial drag forces) required for stent graft migration for certain stents types are lower than the drag forces calculated in this study. It is believed that the results of this study can provide guidelines for the quantitative analyses of the in vivo drag forces experienced by stent grafts and could therefore be used as design criteria for such devices.

[1]  A. Lumsden,et al.  Detection of isolated hook fractures 36 months after implantation of the Ancure endograft: a cautionary note. , 2001, Journal of vascular surgery.

[2]  G. Kopchok,et al.  Changes in arterial wall compliance after endovascular stenting. , 1994, Journal of vascular surgery.

[3]  A Rachev,et al.  A model of stress-induced geometrical remodeling of vessel segments adjacent to stents and artery/graft anastomoses. , 2000, Journal of theoretical biology.

[4]  M. Horrocks,et al.  Experimental assessment of proximal stent-graft (InterVascular) fixation in human cadaveric infrarenal aortas. , 1999, European Journal of Vascular and Endovascular Surgery.

[5]  B Hillen,et al.  Linear and nonlinear one-dimensional models of pulse wave transmission at high Womersley numbers. , 1989, Journal of biomechanics.

[6]  Larry H Hollier,et al.  Mechanical failure of prosthetic human implants: a 10-year experience with aortic stent graft devices. , 2003, Journal of vascular surgery.

[7]  Conti Jc,et al.  Radial compliance of natural and mock arteries: how this property defines the cyclic loading of deployed vascular stents. , 2002 .

[8]  T. Resch,et al.  The impact of stent-graft development on outcome of AAA repair--a 7-year experience. , 2001, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[9]  J. Womersley,et al.  An Elastic Tube Theory of Pulse Transmission and Oscillatory Flow in Mammalian Arteries , 1957 .

[10]  T. Resch,et al.  The impact of stent design on proximal stent-graft fixation in the abdominal aorta: an experimental study. , 2000, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[11]  R. Budwig,et al.  Model studies of the flow in abdominal aortic aneurysms during resting and exercise conditions. , 1999, Journal of biomechanics.

[12]  G. McVeigh,et al.  Evaluation of mechanical arterial properties: clinical, experimental and therapeutic aspects. , 2002, Clinical science.

[13]  B. Hopkinson,et al.  Lessons learned from the long-term follow-up of a first-generation aortic stent graft. , 2003, Journal of vascular surgery.

[14]  E. Chaikof,et al.  Efficacy of a bifurcated endograft versus open repair of abdominal aortic aneurysms: a reappraisal. , 2002, Journal of vascular surgery.

[15]  B. Sonesson,et al.  Sex difference in the mechanical properties of the abdominal aorta in human beings. , 1994, Journal of vascular surgery.

[16]  A A Van Steenhoven,et al.  Linear propagation of pulsatile waves in viscoelastic tubes. , 1989, Journal of biomechanics.

[17]  T Länne,et al.  Abdominal aortic aneurysm: a general defect in the vasculature with focal manifestations in the abdominal aorta? , 1997, Journal of vascular surgery.

[18]  W. Nichols McDonald's Blood Flow in Arteries , 1996 .

[19]  G Moulin,et al.  Hemodynamics and wall mechanics after stent placement in swine iliac arteries: comparative results from six stent designs. , 1999, Radiology.

[20]  J. Humphrey,et al.  Elastodynamics and Arterial Wall Stress , 2002, Annals of Biomedical Engineering.

[21]  M. Lindh,et al.  Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration? , 1998, Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery.

[22]  Timothy J. Pedley,et al.  The fluid mechanics of large blood vessels , 1980 .

[23]  S M Andrews,et al.  In vitro evaluation of endovascular stents to assess suitability for endovascular graft fixation. , 1995, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[24]  C. Schlensak,et al.  Serious complications that require surgical interventions after endoluminal stent-graft placement for the treatment of infrarenal aortic aneurysms. , 2001, Journal of vascular surgery.

[25]  T. Chuter,et al.  Stent-Graft Design: The Good, the Bad and the Ugly , 2002, Cardiovascular surgery.

[26]  Elena S. Di Martino,et al.  Fluid-structure interaction within realistic three-dimensional models of the aneurysmatic aorta as a guidance to assess the risk of rupture of the aneurysm. , 2001, Medical engineering & physics.

[27]  R. Cobbold,et al.  Evidence of a possible link between poststenotic dilation and wall shear stress. , 1990, Journal of vascular surgery.

[28]  Y. Fung,et al.  BIOMECHANICS: CIRCULATION, 2ND EDITION , 1998 .

[29]  M. Zamir,et al.  The Physics of Pulsatile Flow , 2000, Biological Physics Series.

[30]  R. Nerem,et al.  An experimental study of the velocity distribution and transition to turbulence in the aorta , 1972, Journal of Fluid Mechanics.

[31]  H Handa,et al.  Stiffness and elastic behavior of human intracranial and extracranial arteries. , 1980, Journal of biomechanics.