Conventional PM 10 inlets available operate at a flow rate of 16.7 l/min. The purpose of this study was to develop and test a PM 10 inlet designed to operate at 50 l/min to be used with a recently developed continuous coarse particle monitor (Misra et al.). Laboratory tests using polystyrene latex particles established the inlet's 50% cutpoint at 9.5 w m. Further evaluation of PM 10 inlet was performed in a wind tunnel at wind speeds of 3, 8, and 24 km/h. Tests showed that the 50% efficiency cutpoint as well as the very sharp particle separation characteristics of the inlet were maintained at these wind speeds. Field evaluation of the PM 10 inlet was performed in Riverside and Rubidoux, CA. A 2.5 w m cutpoint round nozzle virtual impactor was attached downstream of the developed PM 10 inlet. The Dichotomous PM 10 Partisol Sampler, operating at a flow rate of 16.7 l/min was used as a reference sampler. The Dichotomous Partisol uses an FRM PM 10 inlet operating at 16.7 l/min to remove particles larger than 10 w m in aerodynamic diameter. Commercially available 4.7 cm Teflon filters were used in both the Partisol and the PM 10 inlet to collect particulate matter (PM). Results showed good agreement between coarse PM (2.5-10 w m) mass concentrations measured by means of the PM 10 inlet and Partisol. Chemical analyses showed excellent agreement between coarse PM concentrations of Al, K, Si, Ca, and Fe obtained by the two samplers. The agreement also persisted for nitrate and sulfate. Finally, the excellent agreement between coarse concentrations of the PM 10 inlet and Partisol persisted for wind speeds up to 19 km/h.
[1]
William C. Hinds,et al.
A Low Velocity Wind Tunnel to Evaluate Inhalability and Sampler Performance for Large Dust Particles
,
1995
.
[2]
Benjamin Y. H. Liu,et al.
Generation of monodisperse aerosol standards
,
1973
.
[3]
J C Chow,et al.
Measurement methods to determine compliance with ambient air quality standards for suspended particles.
,
1995,
Journal of the Air & Waste Management Association.
[4]
K. Willeke,et al.
INERTIAL IMPACTORS: THEORY, DESIGN AND USE
,
1976
.
[5]
P. Solomon,et al.
Development and Evaluation of a Continuous Coarse (PM10–PM25) Particle Monitor
,
2001,
Journal of the Air & Waste Management Association.
[6]
W. Hinds,et al.
Comparison of a Simplified and Full-Size Mannequin for the Evaluation of Inhalable Sampler Performance
,
2001
.