A Heterodyne Interferometer with Separated Beam Paths for High-Precision Displacement and Angular Measurements

As standard concepts for precision positioning within a machine reach their limits with increasing measurement volumes, inverse concepts are a promising approach for addressing this problem. The inverse principle entails other limitations, as for high-precision positioning of a sensor head within a large measurement volume, three four-beam interferometers are required in order to measure all necessary translations and rotations of the sensor head and reconstruct the topography of the reference system consisting of fixed mirrors in the x -, y -, and z -directions. We present the principle of a passive heterodyne laser interferometer with consequently separated beam paths for the individual heterodyne frequencies. The beam path design is illustrated and described, as well as the design of the signal-processing and evaluation algorithm, which is implemented using a System-On-a-Chip with an integrated FPGA, CPU, and A/D converters. A streamlined bench-top optical assembly was set up and measurements were carried out to investigate the remaining non-linearities. Additionally, reference measurements with a commercial homodyne interferometer were executed.

[1]  Pengcheng Hu,et al.  Spatially separated heterodyne grating interferometer for eliminating periodic nonlinear errors. , 2017, Optics express.

[2]  Xiangzhi Yu,et al.  Development of a compact, fiber-coupled, six degree-of-freedom measurement system for precision linear stage metrology. , 2016, The Review of scientific instruments.

[3]  J. Lawall,et al.  Heterodyne interferometer with subatomic periodic nonlinearity. , 1999, Applied optics.

[4]  Eberhard Manske,et al.  Heterodyne interferometer laser source with a pair of two phase locked loop coupled He–Ne lasers by 632.8 nm , 2012 .

[5]  Andreas Müller,et al.  Nanopositioning and nanomeasuring machine NPMM-200—a new powerful tool for large-range micro- and nanotechnology , 2016 .

[6]  Jun Luo,et al.  A dual-heterodyne laser interferometer for simultaneous measurement of linear and angular displacements. , 2015, The Review of scientific instruments.

[7]  S. Woody,et al.  Compact fiber-coupled three degree-of-freedom displacement interferometry for nanopositioning stage calibration , 2014 .

[8]  Clemens Elster,et al.  Traceable multiple sensor system for measuring curved surface profiles with high accuracy and high lateral resolution , 2006 .

[9]  Tao Jin,et al.  A Heterodyne Interferometer for Simultaneous Measurement of Roll and Straightness , 2019, IEEE Access.

[10]  J. Lawall,et al.  Michelson Interferometry With 10 PM Accuracy , 2000 .

[11]  Andreas Meister,et al.  Scale spanning subnanometer metrology up to ten decades , 2019, Optical Metrology.

[12]  Axel Wiegmann,et al.  Improving the lateral resolution of a multi-sensor profile measurement method by non-equidistant sensor spacing. , 2010, Optics express.

[13]  Birk Andreas,et al.  A heterodyne interferometer with periodic nonlinearities smaller than ±10 pm , 2012 .