Total body irradiation with a compensator fabricated using a 3D optical scanner and a 3D printer

We propose bilateral total body irradiation (TBI) utilizing a 3D printer and a 3D optical scanner. We acquired surface information of an anthropomorphic phantom with the 3D scanner and fabricated the 3D compensator with the 3D printer, which could continuously compensate for the lateral missing tissue of an entire body from the beam's eye view. To test the system's performance, we measured doses with optically stimulated luminescent dosimeters (OSLDs) as well as EBT3 films with the anthropomorphic phantom during TBI without a compensator, conventional bilateral TBI, and TBI with the 3D compensator (3D TBI). The 3D TBI showed the most uniform dose delivery to the phantom. From the OSLD measurements of the 3D TBI, the deviations between the measured doses and the prescription dose ranged from  -6.7% to 2.4% inside the phantom and from  -2.3% to 0.6% on the phantom's surface. From the EBT3 film measurements, the prescription dose could be delivered to the entire body of the phantom within  ±10% accuracy, except for the chest region, where tissue heterogeneity is extreme. The 3D TBI doses were much more uniform than those of the other irradiation techniques, especially in the anterior-to-posterior direction. The 3D TBI was advantageous, owing to its uniform dose delivery as well as its efficient treatment procedure.

[1]  B. Hoerni,et al.  Total body irradiation (T.B.I.). Preliminary results of a new technique in 30 patients with hematologic malignancy. , 1979, Strahlentherapie.

[2]  U Quast,et al.  Physical treatment planning of total-body irradiation: patient translation and beam-zone method. , 1985, Medical physics.

[3]  H. Thames,et al.  Effect of dose-rate on total body irradiation: lethality and pathologic findings. , 1985, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  J. R. Turner,et al.  Total-body irradiation on an isocentric linear accelerator: a radiation output compensation technique. , 1994, Physics in medicine and biology.

[5]  P Genest,et al.  A translating-bed technique for total-body irradiation. , 1994, Physics in medicine and biology.

[6]  O. S. Nielsen,et al.  Effect of radiation dose rate and cyclophosphamide on pulmonary toxicity after total body irradiation in a mouse model. , 1996, International journal of radiation oncology, biology, physics.

[7]  B Umek,et al.  Total body irradiation with translation method. , 1996, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  H. Deeg,et al.  Dose rate-dependent sparing of the gastrointestinal tract by fractionated total body irradiation in dogs given marrow autografts. , 1998, International journal of radiation oncology, biology, physics.

[9]  M. Chrétien,et al.  A variable speed translating couch technique for total body irradiation. , 2000, Medical physics.

[10]  Cedric X. Yu,et al.  A translational couch technique for total body irradiation. , 2001 .

[11]  P. J. Taylor,et al.  Total body irradiation using a modified standing technique: a single institution 7 year experience. , 2001, The British journal of radiology.

[12]  Paolo Gallina,et al.  Implementation of a water compensator for total body irradiation , 2005, IEEE Transactions on Biomedical Engineering.

[13]  Susanta K Hui,et al.  Feasibility study of helical tomotherapy for total body or total marrow irradiationa). , 2005, Medical physics.

[14]  Luc Beaulieu,et al.  Attenuator design for organs at risk in total body irradiation using a translation technique. , 2008, Medical physics.

[15]  Feasibility study for linac-based intensity modulated total marrow irradiation. , 2008 .

[16]  J. Molloy Statistical analysis of dose heterogeneity in circulating blood: implications for sequential methods of total body irradiation. , 2010, Medical physics.

[17]  L. Beaulieu,et al.  3D heterogeneous dose distributions for total body irradiation patients , 2011, Journal of applied clinical medical physics.

[18]  J. Roeske,et al.  Linear accelerator-based intensity-modulated total marrow irradiation technique for treatment of hematologic malignancies: a dosimetric feasibility study. , 2011, International journal of radiation oncology, biology, physics.

[19]  P. Dunscombe,et al.  Aperture modulated, translating bed total body irradiation. , 2011, Medical physics.

[20]  W. Sensakovic,et al.  A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity. , 2012, Medical physics.

[21]  C. Onal,et al.  Evaluation of field-in-field technique for total body irradiation. , 2012, International journal of radiation oncology, biology, physics.

[22]  J. Pouliot,et al.  Inverse-planned modulated-arc total-body irradiation. , 2012, Medical physics.

[23]  P. Dunscombe,et al.  Total body irradiation dose optimization based on radiological depth , 2012, Journal of applied clinical medical physics.

[24]  J. Pouliot,et al.  Dosimetric aspects of inverse-planned modulated-arc total-body irradiation. , 2012, Medical physics.

[25]  K. Chuang,et al.  Total Body Irradiation with Step Translation and Dynamic Field Matching , 2013, BioMed research international.

[26]  T. Pawlicki,et al.  Feasibility study on dosimetry verification of volumetric‐modulated arc therapy‐based total marrow irradiation , 2013, Journal of Applied Clinical Medical Physics.

[27]  Vanessa M. Hubbard-Lucey,et al.  Enhanced Responses to Tumor Immunization Following Total Body Irradiation Are Time-Dependent , 2013, PloS one.

[28]  Young Seok Kim,et al.  Effects of total body irradiation-based conditioning on allogeneic stem cell transplantation for pediatric acute leukemia: a single-institution study , 2014, Radiation oncology journal.

[29]  R. Chityala,et al.  Multi-institutional feasibility study of a fast patient localization method in total marrow irradiation with helical tomotherapy: a global health initiative by the international consortium of total marrow irradiation. , 2015, International journal of radiation oncology, biology, physics.

[30]  M. Scorsetti,et al.  In-vivo dosimetry with Gafchromic films for multi-isocentric VMAT irradiation of total marrow lymph-nodes: a feasibility study , 2015, Radiation Oncology.

[31]  E. Ford,et al.  TBI Technique Improvements for Anesthetized Pediatric Patients Based on Near-Miss Incident Reporting , 2016 .

[32]  Tae-Suk Suh,et al.  A depth-sensing technique on 3D-printed compensator for total body irradiation patient measurement and treatment planning. , 2016, Medical physics.