Couette charger for measurement of equilibrium and energization flow electrification parameters: application to transformer insulation

The fluid under test (e.g. transformer oil) fills the annulus between coaxial circular cylinders that are covered by the solid of interest (e.g., metal or oil-impregnated paper backed by metal). The inner cylinder can rotate at speeds giving controlled laminar and turbulent flows (for fluids as viscous as transformer oil). This relatively compact apparatus allows for flexibility in testing liquids, trace impurities, and solid insulation without involving large amounts of material. By virtue of the reentrant flow, it acts like a pipe of infinite length and thus provides for the measurement of basic electrification parameters even in highly insulating systems, where the electrical development length for a pipe flow system is likely to be longer than the practical length of a test section. By sampling the charge entrained in the azimuthal flow at a sufficiently slow rate, equilibrium parameters can be deduced. >

[1]  Y. Miura,et al.  Static Electrification by Forced Oil Flow in Large Power Transformer , 1980, IEEE Transactions on Power Apparatus and Systems.

[2]  Steven Marc Gasworth,et al.  Electrification by liquid dielectric flow , 1986, Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1986.

[3]  Tanaka Toshihide,et al.  Characteristics of streaming electrification in pressboard pipe and the influence of an external electric field , 1985 .

[4]  T. Nitta,et al.  Model Approach to the Static Electrification Phenomena Induced by the Flow of Oil in Large Power Transformers , 1980, IEEE Transactions on Power Apparatus and Systems.

[5]  S. Shimizu,et al.  Electrostatics in Power Transformers , 1979, IEEE Transactions on Power Apparatus and Systems.

[6]  H L Walmsley,et al.  The generation of electric currents by the laminar flow of dielectric liquids , 1981 .

[7]  Ain A. Sonin,et al.  Theory for electric charging in turbulent pipe flow , 1982, Journal of Fluid Mechanics.

[8]  S. Chandrasekhar Hydrodynamic and Hydromagnetic Stability , 1961 .

[9]  H. Schlichting Boundary Layer Theory , 1955 .

[10]  T. Oommen,et al.  Eelectrostatic Charging Tendency of Transformer Oils , 1984, IEEE Transactions on Power Apparatus and Systems.

[11]  H. Miyao,et al.  A Calculation of Potential Distribution Caused by Static Electrification Owing to Oil Flow in a Oil-Paper Insulation System and it's Application to Partial Discharge Phenomena in Oil , 1979, IEEE Transactions on Power Apparatus and Systems.

[12]  Geoffrey Ingram Taylor,et al.  Fluid Friction between Rotating Cylinders. I. Torque Measurements , 1936 .

[13]  Jf Roach,et al.  An Engineering Model for Streaming Electrification in Power Transformers , 1988 .

[14]  G. Taylor Stability of a Viscous Liquid Contained between Two Rotating Cylinders , 1923 .

[15]  J. Gavis,et al.  Development of charge in low-conductivity liquids flowing past surfaces: Engineering predictions from the theory developed for tube flow , 1962 .

[16]  K. Hiraishi,et al.  Static Electrification and Partial Discharges Caused by Oil Flow in Forced Oil Cooled Core Type Transformers , 1979, IEEE Transactions on Power Apparatus and Systems.

[17]  H. Okubo,et al.  Suppression of Static Electrification of Insulating Oil for Large Power Transformers , 1982, IEEE Transactions on Power Apparatus and Systems.

[18]  Ain A. Sonin,et al.  Electric currents generated by turbulent flows of liquid hydrocarbons in smooth pipes: Experiment vs. theory , 1986 .

[19]  Patrick Li,et al.  Low frequency, millimeter wavelength, interdigital dielectrometry of insulating media in a transformer environment , 1987 .