Improving the scan rate and image quality in tapping Mode Atomic Force Microscopy with piezoelectric shunt control

The scan rate of tapping mode Atomic Force Microscopy (AFM), when scanning in air, may be improved by reducing the quality (Q) factor of the micro-cantilever. Passive piezoelectric shunt control is implemented in the AFM by placing an electrical impedance in series with the cantilever tip oscillation circuit. This method is used to reduce the Q factor of a piezoelectric self actuating AFM micro-cantilever by a factor of 8. Experimental results demonstrate that scan rate and image quality may be improved significantly using this method.

[1]  D.R. Sahoo,et al.  Observer based imaging methods for Atomic Force Microscopy , 2005, Proceedings of the 44th IEEE Conference on Decision and Control.

[2]  Robert L. Forward,et al.  Electronic damping of vibrations in optical structures. , 1979, Applied optics.

[3]  S. O. Reza Moheimani,et al.  A survey of recent innovations in vibration damping and control using shunted piezoelectric transducers , 2003, IEEE Trans. Control. Syst. Technol..

[4]  S. O. Reza Moheimani,et al.  Control orientated synthesis of high-performance piezoelectric shunt impedances for structural vibration control , 2005, IEEE Transactions on Control Systems Technology.

[5]  Cagatay Basdogan,et al.  State feedback control for adjusting the dynamic behavior of a piezoactuated bimorph atomic force microscopy probe. , 2009, The Review of scientific instruments.

[6]  A J Fleming,et al.  Passive shunt damping of a piezoelectric stack nanopositioner , 2010, Proceedings of the 2010 American Control Conference.

[7]  S. O. Reza Moheimani,et al.  Passive piezoelectric shunt control of an Atomic Force Microscope microcantilever , 2011, 2011 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM).

[8]  S. O. Reza Moheimani,et al.  Sensor-less Vibration Suppression and Scan Compensation for Piezoelectric Tube Nanopositioners , 2005, CDC 2005.

[9]  Toma s R. Rodri guez,et al.  Theory of Q control in atomic force microscopy , 2003 .

[10]  B. L. Smith,et al.  Biological applications of the AFM: From single molecules to organs , 1997, Int. J. Imaging Syst. Technol..

[11]  Nesbitt W. Hagood,et al.  Damping of structural vibrations with piezoelectric materials and passive electrical networks , 1991 .

[12]  Jerome Mertz,et al.  Regulation of a microcantilever response by force feedback , 1993 .

[13]  S. S. Aphale,et al.  High speed nano-scale positioning using a piezoelectric tube actuator with active shunt control , 2007 .

[14]  Ricardo Garcia,et al.  Dynamic atomic force microscopy methods , 2002 .

[15]  Á. S. Paulo,et al.  High-resolution imaging of antibodies by tapping-mode atomic force microscopy: attractive and repulsive tip-sample interaction regimes. , 2000, Biophysical journal.

[16]  Gerber,et al.  Atomic Force Microscope , 2020, Definitions.

[17]  Andrew J. Fleming,et al.  Synthetic impedance for implementation of piezoelectric shunt-damping circuits , 2000 .