Optimization of a Patient-Specific External Fixation Device for Lower Limb Injuries

The use of external fixation devices is considered a valuable approach for the treatment of bone fractures, providing proper alignment to fractured fragments and maintaining fracture stability during the healing process. The need for external fixation devices has increased due to an aging population and increased trauma incidents. The design and fabrication of external fixations are major challenges since the shape and size of the defect vary, as well as the geometry of the human limb. This requires fully personalized external fixators to improve its fit and functionality. This paper presents a methodology to design personalized lightweight external fixator devices for additive manufacturing. This methodology comprises data acquisition, Computer tomography (CT) imaging analysis and processing, Computer Aided Design (CAD) modelling and two methods (imposed predefined patterns and topology optimization) to reduce the weight of the device. Finite element analysis with full factorial design of experiments were used to determine the optimal combination of designs (topology optimization and predefined patterns), materials (polylactic acid, acrylonitrile butadiene styrene, and polyamide) and thickness (3, 4, 5 and 6 mm) to maximize the strength and stiffness of the fixator, while minimizing its weight. The optimal parameters were found to correspond to an external fixator device optimized by topology optimization, made in polylactic acid with 4 mm thickness.

[1]  T. Chung LOWER-LIMB ORTHOSES , 2022, JPO Journal of Prosthetics and Orthotics.

[2]  R. Omar,et al.  Rheological investigation of synthetic-based drilling fluid containing non-ionic surfactant pentaerythritol ester using full factorial design , 2021 .

[3]  S. Amini,et al.  Ultrasonic-assisted friction drilling process of aerospace aluminum alloy (AA7075): FEA and experimental study , 2021 .

[4]  Prahalada K. Rao,et al.  Recurrence network analysis of design-quality interactions in additive manufacturing. , 2021, Additive manufacturing.

[5]  M. Salmi Additive Manufacturing Processes in Medical Applications , 2021, Materials.

[6]  Mohammed Rafiq Abdul Kadir,et al.  Biomechanical evaluation of three different configurations of external fixators for treating distal third tibia fracture: Finite element analysis in axial, bending and torsion load , 2020, Comput. Biol. Medicine.

[7]  A. Sandu,et al.  Design of Experiment in the Milling Process of Aluminum Alloys in the Aerospace Industry , 2020, Applied Sciences.

[8]  E. Zanetti,et al.  Engineering and Manufacturing of a Dynamizable Fracture Fixation Device System , 2020, Applied Sciences.

[9]  F. Gao,et al.  Application of the Ilizarov technique for knee joint arthrodesis as a treatment for end-stage tuberculosis of the knee , 2020, BMC Musculoskeletal Disorders.

[10]  Abdalla M. Omar,et al.  Mechanical, biological and tribological behaviour of fixation plates 3D printed by electron beam and selective laser melting , 2020, The International Journal of Advanced Manufacturing Technology.

[11]  M. Yasir,et al.  Fabrication and Characterization of Zein/Hydroxyapatite Composite Coatings for Biomedical Applications , 2020, Surfaces.

[12]  E. Rodríguez‐Merchán,et al.  The use of external fixation in the emergency department: applications, common errors, complications and their treatment , 2020, EFORT open reviews.

[13]  D. Shi,et al.  Investigating the biomechanical function of the plate-type external fixator in the treatment of tibial fractures: a biomechanical study , 2020, BMC Musculoskeletal Disorders.

[14]  Qing Li,et al.  Time-dependent topology optimization of bone plates considering bone remodeling , 2020 .

[15]  Paulo Bártolo,et al.  A review on the use of additive manufacturing to produce lower limb orthoses , 2019, Progress in Additive Manufacturing.

[16]  P. Bártolo,et al.  Stress analysis in a bone fracture fixed with topology-optimised plates , 2019, Biomechanics and modeling in mechanobiology.

[17]  Jack Porrino,et al.  External fixators: looking beyond the hardware maze , 2019, Skeletal Radiology.

[18]  P. Augat,et al.  External fixation of the lower extremities: Biomechanical perspective and recent innovations. , 2019, Injury.

[19]  P. Mendis,et al.  Effects of dynamic loading on fracture healing under different locking compression plate configurations: A finite element study. , 2019, Journal of the mechanical behavior of biomedical materials.

[20]  Ibrahim Deiab,et al.  Comparative study of a topologically optimized lower limb prosthesis , 2019, International Journal on Interactive Design and Manufacturing (IJIDeM).

[21]  Fernando Blaya Haro,et al.  Design of a Functional Splint for Rehabilitation of Achilles Tendon Injury Using Advanced Manufacturing (AM) Techniques. Implementation Study , 2019, Journal of Medical Systems.

[22]  Richard J. Bibb,et al.  Design rules for additively manufactured wrist splints created using design of experiment methods , 2018 .

[23]  F. Luyten,et al.  Bone regeneration strategies: Engineered scaffolds, bioactive molecules and stem cells current stage and future perspectives. , 2018, Biomaterials.

[24]  Javier Guerrero,et al.  Topology optimization and additive manufacturing for aerospace components , 2018, Progress in Additive Manufacturing.

[25]  R. Ji,et al.  A theoretical analysis and finite element simulation of fixator–bone system stiffness on healing progression , 2018, Journal of applied biomaterials & functional materials.

[26]  P. Bártolo,et al.  Metallic bone fixation implants: a novel design approach for reducing the stress shielding phenomenon , 2017 .

[27]  Hao Zhu,et al.  An optimization procedure for spot-welded structures based on SIMP method , 2016 .

[28]  G. Chryssolouris,et al.  Additive manufacturing methods and modelling approaches: a critical review , 2016 .

[29]  R. Sellei,et al.  External fixation design evolution enhances biomechanical frame performance. , 2015, Injury.

[30]  R. Sellei,et al.  Biomechanical properties of different external fixator frame configurations , 2015, European Journal of Trauma and Emergency Surgery.

[31]  Marcelo Back Sternick,et al.  RELATIONSHIP BETWEEN RIGIDITY OF EXTERNAL FIXATOR AND NUMBER OF PINS: COMPUTER ANALYSIS USING FINITE ELEMENTS , 2012, Revista brasileira de ortopedia.

[32]  Dae-Sung Son,et al.  Finite element analysis of the effect of bending stiffness and contact condition of composite bone plates with simple rectangular cross-section on the bio-mechanical behaviour of fractured long bones , 2011 .

[33]  Guigen Zhang,et al.  Geometric and material nonlinearity in tensioned wires of an external fixator. , 2004, Clinical biomechanics.

[34]  N Maffulli,et al.  Yielding of the clamped-wire system in the Ilizarov external fixator , 2003, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[35]  S. Ramakrishna,et al.  Advanced textile composite ring for Ilizarov external fixator system , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[36]  K J Mathias,et al.  External ring fixators: An overview , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[37]  Xianmin Zhang,et al.  Design of compliant mechanisms using continuum topology optimization: A review , 2020 .

[38]  L. Murr,et al.  Metallurgy principles applied to powder bed fusion 3D printing/additive manufacturing of personalized and optimized metal and alloy biomedical implants: an overview , 2020 .

[39]  Mazher Iqbal Mohammed,et al.  Design and additive manufacturing of a patient specific polymer thumb splint concept , 2018 .

[40]  Chris Peach,et al.  Topology Optimization to reduce the stress shielding effect for orthopedic applications , 2017 .

[41]  E. Friis,et al.  Mechanical testing of fracture fixation devices , 2017 .

[42]  Sebastian Białkowski Structural Optimisation Methods as a New Toolset for Architects , 2016, Proceedings of the 34th International Conference on Education and Research in Computer Aided Architectural Design in Europe (eCAADe) [Volume 2].

[43]  Mešić Elmedin,et al.  International Symposium on Intelligent Manufacturing and Automation , DAAAM 2014 Finite Element Analysis and Experimental Testing of Stiffness of the Sarafix External Fixator , 2015 .

[44]  I. Ashcroft,et al.  Topology Optimization for Additive Manufacturing , 2011 .

[45]  Joel Oliveira,et al.  Natural Origin Materials for Bone Tissue Engineering – Properties, Processing, and Performance , 2011 .

[46]  N. Tejwani,et al.  Biomechanics of external fixation: a review of the literature. , 2007, Bulletin of the NYU hospital for joint diseases.