Automatic Robust Medical Image Registration Using a New Democratic Vector Optimization Approach with Multiple Measures

The registration of various data is a challenging task in medical image processing and a highly frequented area of research. Most of the published approaches tend to fail sporadically on different data sets. This happens due to two major problems. First, local optimization strategies induce a high risk when optimizing nonconvex functions. Second, similarity measures might fail if they are not suitable for the data. Thus, researchers began to combine multiple measures by weighted sums. In this paper, we show severe limitations of such summation approaches. We address both issues by a gradient-based vector optimization algorithm that uses multiple similarity measures. It gathers context information from the iteration process to detect and suppress failing measures. The new approach is evaluated by experiments from the field of 2D-3D registration. Besides its generic character with respect to arbitrary data, the main benefit is a highly robust iteration behavior, where even very poor initial guesses of the transform result in good solutions.

[1]  L. Joskowicz,et al.  Gradient-based 2-D/3-D rigid registration of fluoroscopic X-ray to CT , 2003, IEEE Transactions on Medical Imaging.

[2]  Max A. Viergever,et al.  A survey of medical image registration , 1998, Medical Image Anal..

[3]  Max A. Viergever,et al.  Image registration by maximization of combined mutual information and gradient information , 2000, IEEE Transactions on Medical Imaging.

[4]  Frank Deinzer,et al.  Kombination verschiedener Ähnlichkeitsmaße für die 2D/3D-Registrierung von Röntgenbildern mittels Demokratischer Integration , 2006, Bildverarbeitung für die Medizin.

[5]  Paul A. Viola,et al.  Alignment by Maximization of Mutual Information , 1997, International Journal of Computer Vision.

[6]  Juan C. Burguillo,et al.  A Combined Global & Local Search (CGLS) Approach to Global Optimization , 2006, J. Glob. Optim..

[7]  Guoyan Zheng,et al.  A Unifying MAP-MRF Framework for Deriving New Point Similarity Measures for Intensity-based 2D-3D Registration , 2006, 18th International Conference on Pattern Recognition (ICPR'06).

[8]  Jürgen Weese,et al.  A comparison of similarity measures for use in 2-D-3-D medical image registration , 1998, IEEE Transactions on Medical Imaging.

[9]  Jochen Triesch,et al.  Democratic Integration: Self-Organized Integration of Adaptive Cues , 2001, Neural Computation.

[10]  Johannes Jahn,et al.  Vector optimization - theory, applications, and extensions , 2004 .

[11]  Thomas Martin Deserno,et al.  Bildverarbeitung für die Medizin: Grundlagen, Modelle, Methoden, Anwendungen , 1997, Bildverarbeitung für die Medizin.