Three-step nonuniformity correction for a highly dynamic intensified charge-coupled device star sensor

Abstract A three-step nonuniformity correction algorithm based on the photoelectrical response models of intensified charge-coupled device (ICCD) for a highly dynamic ICCD star sensor is proposed in the current paper. The influence factors of nonuniformity correction precision are analyzed based on the photoelectrical imaging theory. The photoelectrical response models of ICCD are obtained using the experimental method, and the nonuniformity correction is implemented in three steps based on the photoelectrical response models. The nonuniformity correction results in constant-radiance images and sky images of the highly dynamic star sensor show that the proposed algorithm has satisfactory correction precision, and the accuracy of the highly dynamic star sensor can be enhanced effectively when sky images are processed using the three-step nonuniformity correction algorithm.

[1]  Christopher R. Costanzo,et al.  Compensation For Gain Nonuniformity And Nonlinearity In Hgcdte Infrared Charge-Coupled-Device Focal Planes , 1987 .

[2]  Malak Samaan,et al.  Toward faster and more accurate star sensors using recursive centroiding and star identification , 2003 .

[3]  E. Dereniak,et al.  Linear theory of nonuniformity correction in infrared staring sensors , 1993 .

[4]  J. Crassidis Angular Velocity Determination Directly from Star Tracker Measurements , 2002 .

[5]  K. Gromov,et al.  Toward a stellar gyroscope for spacecraft attitude determination , 2004 .

[6]  R. W. Helfrich Programmable Compensation Technique For Staring Arrays , 1979, Other Conferences.

[7]  S. Nudelman Photoelectronic imaging devices , 1971 .

[8]  Carl Christian Liebe,et al.  Accuracy performance of star trackers - a tutorial , 2002 .

[9]  A. Katake,et al.  Modeling, image processing and attitude estimation of high speed star sensors , 2009 .

[10]  M. Kruer,et al.  Influence Of Nonuniformity On Infrared Focal Plane Array Performance , 1985 .

[11]  Jonathan Martin Mooney,et al.  Responsivity Nonuniformity Limited Performance Of Infrared Staring Cameras , 1989 .

[12]  C. Liebe Star trackers for attitude determination , 1995 .

[13]  G. V. Poropat Nonlinear Compensation For Responsivity Nonuniformities In Cadmium Mercury Telluride Focal Plane Detector Arrays For Use In The 8 To 12 μm Spectral Region , 1989 .

[14]  George C. Goldsmith,et al.  Combined calibration and nonuniformity correction of a sensor for improved projector nonuniformity correction , 2004, SPIE Defense + Commercial Sensing.

[15]  Huixin Zhou,et al.  New improved nonuniformity correction for infrared focal plane arrays , 2005 .